Name | 08398135_36_0 |
Workunit | 8564447 |
Created | 10 Jul 2021, 22:05:00 UTC |
Sent | 11 Jul 2021, 10:35:22 UTC |
Report deadline | 16 Jul 2021, 10:35:22 UTC |
Received | 11 Jul 2021, 11:15:18 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | -2147467259 (0x80004005) Unknown error code |
Computer ID | 9800 |
Run time | 17 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 5.15 GFLOPS |
Application version | boinc2docker v1.14 (vbox64_mt) windows_x86_64 |
Peak working set size | 10.45 MB |
Peak swap size | 6.25 MB |
Peak disk usage | 498.85 MB |
<core_client_version>7.16.11</core_client_version> <![CDATA[ <message> Uspecificeret fejl (0x80004005) - exit code 2147500037 (0x80004005)</message> <stderr_txt> 2021-07-11 13:13:16 (5744): Detected: vboxwrapper 26202 2021-07-11 13:13:16 (5744): Detected: BOINC client v7.16.11 2021-07-11 13:13:17 (5744): Detected: VirtualBox VboxManage Interface (Version: 6.1.22) 2021-07-11 13:13:18 (5744): Create VM. (boinc_4d23bf3ea8ffe04e, slot#0) 2021-07-11 13:13:18 (5744): Updating drive controller type and model for desired configuration. 2021-07-11 13:13:18 (5744): Setting Memory Size for VM. (3072MB) 2021-07-11 13:13:19 (5744): Setting CPU Count for VM. (1) 2021-07-11 13:13:19 (5744): Setting Chipset Options for VM. 2021-07-11 13:13:19 (5744): Setting Boot Options for VM. 2021-07-11 13:13:19 (5744): Setting Network Configuration for NAT. 2021-07-11 13:13:20 (5744): Enabling VM Network Access. 2021-07-11 13:13:20 (5744): Disabling USB Support for VM. 2021-07-11 13:13:20 (5744): Disabling COM Port Support for VM. 2021-07-11 13:13:21 (5744): Disabling LPT Port Support for VM. 2021-07-11 13:13:21 (5744): Disabling Audio Support for VM. 2021-07-11 13:13:21 (5744): Disabling Clipboard Support for VM. 2021-07-11 13:13:21 (5744): Disabling Drag and Drop Support for VM. 2021-07-11 13:13:22 (5744): Adding storage controller(s) to VM. 2021-07-11 13:13:22 (5744): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso) 2021-07-11 13:13:22 (5744): Adding VirtualBox Guest Additions to VM. 2021-07-11 13:13:22 (5744): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2021-07-11 13:13:23 (5744): Enabling shared directory for VM. 2021-07-11 13:13:23 (5744): Starting VM using VBoxManage interface. (boinc_4d23bf3ea8ffe04e, slot#0) 2021-07-11 13:13:25 (5744): Error in start VM for VM: -2147467259 Command: VBoxManage -q startvm "boinc_4d23bf3ea8ffe04e" --type headless Output: Waiting for VM "boinc_4d23bf3ea8ffe04e" to power on... VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2021-07-11 13:13:25 (5744): VM failed to start. 2021-07-11 13:13:25 (5744): Could not start 2021-07-11 13:13:25 (5744): ERROR: VM failed to start 2021-07-11 13:13:25 (5744): Powering off VM. 2021-07-11 13:13:25 (5744): Deregistering VM. (boinc_4d23bf3ea8ffe04e, slot#0) 2021-07-11 13:13:25 (5744): Removing network bandwidth throttle group from VM. 2021-07-11 13:13:26 (5744): Removing VM from VirtualBox. 2021-07-11 13:13:26 (5744): Removing virtual ISO 9660 disk from VirtualBox. Hypervisor System Log: 00:00:00.060024 C:\WINDOWS\system32\DRIVERS\VBoxNetAdp6.sys (Version: 6.1.22.44080) 00:00:00.063519 Loading settings file "C:\Users\groos\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:00.067844 usbLibGetDevices: Starting USB device enumeration 00:00:00.082209 usbLibGetDevices: Found 4 USB devices, 0 captured 00:00:00.196357 HostDnsMonitor: initializing 00:00:00.201793 HostDnsMonitor: updating information 00:00:00.201813 HostDnsMonitor: old information 00:00:00.201813 no server entries 00:00:00.201814 no domain set 00:00:00.201814 no search string entries 00:00:00.201814 HostDnsMonitor: new information 00:00:00.201815 server 1: 192.168.1.1 00:00:00.201815 no domain set 00:00:00.201816 no search string entries 00:00:00.252577 SUPR0QueryVTCaps -> VERR_VMX_MSR_ALL_VMX_DISABLED 00:00:00.252966 VD: VDInit finished with VINF_SUCCESS 00:00:00.253853 VirtualBox: object created 00:00:00.797955 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={Could not find a registered machine named 'boinc_4d23bf3ea8ffe04e'}, preserve=false aResultDetail=0 00:00:01.074450 ERROR [COM]: aRC=VBOX_E_FILE_ERROR (0x80bb0004) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Could not find file for the medium 'C:\ProgramData\BOINC\slots\0\vm_image.vdi' (VERR_FILE_NOT_FOUND)}, preserve=false aResultDetail=-102 00:00:01.336606 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_4d23bf3ea8ffe04e\boinc_4d23bf3ea8ffe04e.vbox" with version "1.16-windows" 00:00:01.338570 Saving settings file "C:\Users\groos\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:01.591541 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_4d23bf3ea8ffe04e\boinc_4d23bf3ea8ffe04e.vbox" with version "1.16-windows" 00:00:01.846010 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_4d23bf3ea8ffe04e\boinc_4d23bf3ea8ffe04e.vbox" with version "1.16-windows" 00:00:02.114792 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_4d23bf3ea8ffe04e\boinc_4d23bf3ea8ffe04e.vbox" with version "1.16-windows" 00:00:02.398381 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_4d23bf3ea8ffe04e\boinc_4d23bf3ea8ffe04e.vbox" with version "1.16-windows" 00:00:02.672245 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_4d23bf3ea8ffe04e\boinc_4d23bf3ea8ffe04e.vbox" with version "1.16-windows" 00:00:02.932346 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_4d23bf3ea8ffe04e\boinc_4d23bf3ea8ffe04e.vbox" with version "1.16-windows" 00:00:03.198361 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_4d23bf3ea8ffe04e\boinc_4d23bf3ea8ffe04e.vbox" with version "1.16-windows" 00:00:03.486570 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_4d23bf3ea8ffe04e\boinc_4d23bf3ea8ffe04e.vbox" with version "1.16-windows" 00:00:03.752008 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_4d23bf3ea8ffe04e\boinc_4d23bf3ea8ffe04e.vbox" with version "1.16-windows" 00:00:04.008176 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_4d23bf3ea8ffe04e\boinc_4d23bf3ea8ffe04e.vbox" with version "1.16-windows" 00:00:04.335548 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_4d23bf3ea8ffe04e\boinc_4d23bf3ea8ffe04e.vbox" with version "1.16-windows" 00:00:04.536504 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_4d23bf3ea8ffe04e\boinc_4d23bf3ea8ffe04e.vbox" with version "1.16-windows" 00:00:04.830591 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_4d23bf3ea8ffe04e\boinc_4d23bf3ea8ffe04e.vbox" with version "1.16-windows" 00:00:05.070028 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_4d23bf3ea8ffe04e\boinc_4d23bf3ea8ffe04e.vbox" with version "1.16-windows" 00:00:05.335178 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:05.336413 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:05.336539 Saving settings file "C:\Users\groos\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:05.340184 Saving settings file "C:\Users\groos\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:05.342429 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_4d23bf3ea8ffe04e\boinc_4d23bf3ea8ffe04e.vbox" with version "1.16-windows" 00:00:05.604315 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:05.605420 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:05.605555 Saving settings file "C:\Users\groos\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:05.609984 Saving settings file "C:\Users\groos\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:05.612384 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_4d23bf3ea8ffe04e\boinc_4d23bf3ea8ffe04e.vbox" with version "1.16-windows" 00:00:05.857496 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_4d23bf3ea8ffe04e\boinc_4d23bf3ea8ffe04e.vbox" with version "1.16-windows" 00:00:06.179274 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_4d23bf3ea8ffe04e\boinc_4d23bf3ea8ffe04e.vbox" with version "1.16-windows" 00:00:06.381585 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:06.381687 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:06.388209 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:06.679325 Launched VM: 65598688 pid: 10680 (0x29b8) frontend: headless name: boinc_4d23bf3ea8ffe04e 00:00:08.764665 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_4d23bf3ea8ffe04e\boinc_4d23bf3ea8ffe04e.vbox" with version "1.16-windows" 00:00:08.811936 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:09.113096 Saving settings file "C:\Users\groos\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:14.389347 main VirtualBox: object deletion starts 00:00:14.389797 main HostDnsMonitor: shutting down ... 00:00:14.389850 main HostDnsMonitor: shut down 00:00:14.391425 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:14.391578 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: 16 Maximum Devices per SCSI Port: 1 Maximum SAS PIIX3 Controllers: 1 Maximum SAS ICH9 Controllers: 8 Maximum SAS Port count: 255 Maximum Devices per SAS Port: 1 Maximum NVMe PIIX3 Controllers: 1 Maximum NVMe ICH9 Controllers: 8 Maximum NVMe Port count: 255 Maximum Devices per NVMe Port: 1 Maximum virtio-scsi PIIX3 Controllers: 1 Maximum virtio-scsi ICH9 Controllers: 8 Maximum virtio-scsi Port count: 256 Maximum Devices per virtio-scsi Port: 1 Maximum PIIX3 Floppy Controllers:1 Maximum ICH9 Floppy Controllers: 1 Maximum Floppy Port count: 1 Maximum Devices per Floppy Port: 2 Default machine folder: C:\Users\groos\VirtualBox VMs Raw-mode Supported: no Exclusive HW virtualization use: off Default hard disk format: VDI VRDE auth library: VBoxAuth Webservice auth. library: VBoxAuth Remote desktop ExtPack: Log history count: 3 Default frontend: Default audio driver: DirectSound Autostart database path: Default Guest Additions ISO: C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso Logging Level: all Proxy Mode: System Proxy URL: 2021-07-11 13:13:17 (5744): Command: VBoxManage -q list hostinfo Exit Code: 0 Output: Host Information: Host time: 2021-07-11T11:13:17.619000000Z Processor online count: 6 Processor count: 6 Processor online core count: 6 Processor core count: 6 Processor supports HW virtualization: no Processor supports PAE: yes Processor supports long mode: yes Processor supports nested paging: no Processor supports unrestricted guest: no Processor supports nested HW virtualization: no Processor#0 speed: unknown Processor#0 description: Intel(R) Core(TM) i5-9600K CPU @ 3.70GHz Processor#1 speed: unknown Processor#1 description: Intel(R) Core(TM) i5-9600K CPU @ 3.70GHz Processor#2 speed: unknown Processor#2 description: Intel(R) Core(TM) i5-9600K CPU @ 3.70GHz Processor#3 speed: unknown Processor#3 description: Intel(R) Core(TM) i5-9600K CPU @ 3.70GHz Processor#4 speed: unknown Processor#4 description: Intel(R) Core(TM) i5-9600K CPU @ 3.70GHz Processor#5 speed: unknown Processor#5 description: Intel(R) Core(TM) i5-9600K CPU @ 3.70GHz Memory size: 16231 MByte Memory available: 7044 MByte Operating system: Windows 10 Operating system version: 10.0.19043 2021-07-11 13:13:18 (5744): Command: VBoxManage -q showvminfo "boinc_4d23bf3ea8ffe04e" --machinereadable Exit Code: -2135228415 Output: VBoxManage.exe: error: Could not find a registered machine named 'boinc_4d23bf3ea8ffe04e' VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2727 of file VBoxManageInfo.cpp 2021-07-11 13:13:18 (5744): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\0/vm_image.vdi" Exit Code: -2135228412 Output: VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\0\vm_image.vdi' (VERR_FILE_NOT_FOUND) VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp 2021-07-11 13:13:18 (5744): Command: VBoxManage -q createvm --name "boinc_4d23bf3ea8ffe04e" --basefolder "C:\ProgramData\BOINC\slots\0" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_4d23bf3ea8ffe04e' is created and registered. UUID: 204e1d43-a2d1-4649-94d9-ae7745d032ae Settings file: 'C:\ProgramData\BOINC\slots\0\boinc_4d23bf3ea8ffe04e\boinc_4d23bf3ea8ffe04e.vbox' 2021-07-11 13:13:18 (5744): Command: VBoxManage -q modifyvm "boinc_4d23bf3ea8ffe04e" --description "08398135_36_0" Exit Code: 0 Output: 2021-07-11 13:13:19 (5744): Command: VBoxManage -q modifyvm "boinc_4d23bf3ea8ffe04e" --memory 3072 Exit Code: 0 Output: 2021-07-11 13:13:19 (5744): Command: VBoxManage -q modifyvm "boinc_4d23bf3ea8ffe04e" --cpus 1 Exit Code: 0 Output: 2021-07-11 13:13:19 (5744): Command: VBoxManage -q modifyvm "boinc_4d23bf3ea8ffe04e" --acpi on --ioapic on Exit Code: 0 Output: 2021-07-11 13:13:19 (5744): Command: VBoxManage -q modifyvm "boinc_4d23bf3ea8ffe04e" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2021-07-11 13:13:20 (5744): Command: VBoxManage -q modifyvm "boinc_4d23bf3ea8ffe04e" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2021-07-11 13:13:20 (5744): Command: VBoxManage -q modifyvm "boinc_4d23bf3ea8ffe04e" --cableconnected1 on Exit Code: 0 Output: 2021-07-11 13:13:20 (5744): Command: VBoxManage -q modifyvm "boinc_4d23bf3ea8ffe04e" --usb off Exit Code: 0 Output: 2021-07-11 13:13:21 (5744): Command: VBoxManage -q modifyvm "boinc_4d23bf3ea8ffe04e" --uart1 off --uart2 off Exit Code: 0 Output: 2021-07-11 13:13:21 (5744): Command: VBoxManage -q modifyvm "boinc_4d23bf3ea8ffe04e" --lpt1 off --lpt2 off Exit Code: 0 Output: 2021-07-11 13:13:21 (5744): Command: VBoxManage -q modifyvm "boinc_4d23bf3ea8ffe04e" --audio none Exit Code: 0 Output: 2021-07-11 13:13:21 (5744): Command: VBoxManage -q modifyvm "boinc_4d23bf3ea8ffe04e" --clipboard disabled Exit Code: 0 Output: 2021-07-11 13:13:22 (5744): Command: VBoxManage -q modifyvm "boinc_4d23bf3ea8ffe04e" --draganddrop disabled Exit Code: 0 Output: 2021-07-11 13:13:22 (5744): Command: VBoxManage -q storagectl "boinc_4d23bf3ea8ffe04e" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2021-07-11 13:13:22 (5744): Command: VBoxManage -q storageattach "boinc_4d23bf3ea8ffe04e" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\ProgramData\BOINC\slots\0/vm_isocontext.iso" Exit Code: 0 Output: 2021-07-11 13:13:22 (5744): Command: VBoxManage -q storageattach "boinc_4d23bf3ea8ffe04e" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2021-07-11 13:13:23 (5744): Command: VBoxManage -q bandwidthctl "boinc_4d23bf3ea8ffe04e" add "boinc_4d23bf3ea8ffe04e_net" --type network --limit 1024G Exit Code: 0 Output: 2021-07-11 13:13:23 (5744): Command: VBoxManage -q sharedfolder add "boinc_4d23bf3ea8ffe04e" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\0/shared" Exit Code: 0 Output: 2021-07-11 13:13:25 (5744): Command: VBoxManage -q startvm "boinc_4d23bf3ea8ffe04e" --type headless Exit Code: -2147467259 Output: Waiting for VM "boinc_4d23bf3ea8ffe04e" to power on... VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2021-07-11 13:13:25 (5744): Command: VBoxManage -q snapshot "boinc_4d23bf3ea8ffe04e" list Exit Code: -108 Output: This machine does not have any snapshots 2021-07-11 13:13:26 (5744): Command: VBoxManage -q bandwidthctl "boinc_4d23bf3ea8ffe04e" remove "boinc_4d23bf3ea8ffe04e_net" Exit Code: 0 Output: VBoxManage.exe: error: Bandwidth groups cannot be deleted while the VM is running 2021-07-11 13:13:26 (5744): Command: VBoxManage -q unregistervm "boinc_4d23bf3ea8ffe04e" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 2021-07-11 13:13:26 (5744): Command: VBoxManage -q closemedium dvd "C:\ProgramData\BOINC\slots\0/vm_isocontext.iso" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 13:13:31 (5744): called boinc_finish(-2147467259) </stderr_txt> ]]>
©2025 COPYRIGHT 2017-2018 NCN