Name | 06462618_076_0 |
Workunit | 131181 |
Created | 10 Feb 2018, 0:17:27 UTC |
Sent | 10 Feb 2018, 1:45:12 UTC |
Report deadline | 10 Feb 2018, 9:45:12 UTC |
Received | 10 Feb 2018, 20:16:12 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | -182 (0xFFFFFF4A) ERR_TIMEOUT |
Computer ID | 334 |
Run time | 2 min 2 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 3.53 GFLOPS |
Application version | boinc2docker v1.11 (vbox64_mt) windows_x86_64 |
Peak working set size | 9.83 MB |
Peak swap size | 5.67 MB |
Peak disk usage | 223.51 MB |
<core_client_version>7.8.3</core_client_version> <![CDATA[ <message> (unknown error) - exit code -182 (0xffffff4a)</message> <stderr_txt> 2018-02-09 17:57:46 (4476): vboxwrapper (7.7.26197): starting 2018-02-09 17:57:46 (4476): Error creating VirtualBox instance! rc = 0x80004002 2018-02-09 17:57:49 (4476): Feature: Checkpoint interval offset (268 seconds) 2018-02-09 17:57:49 (4476): Detected: VirtualBox VboxManage Interface (Version: 5.2.6) 2018-02-09 17:57:52 (4476): Detected: Minimum checkpoint interval (600.000000 seconds) 2018-02-09 17:57:56 (4476): Create VM. (boinc_633b9e660e8c13fc, slot#36) 2018-02-09 17:57:56 (4476): Updating drive controller type and model for desired configuration. 2018-02-09 17:58:01 (4476): Setting Memory Size for VM. (3072MB) 2018-02-09 17:58:03 (4476): Setting CPU Count for VM. (1) 2018-02-09 17:58:05 (4476): Setting Chipset Options for VM. 2018-02-09 17:58:07 (4476): Setting Boot Options for VM. 2018-02-09 17:58:09 (4476): Setting Network Configuration for NAT. 2018-02-09 17:58:10 (4476): Enabling VM Network Access. 2018-02-09 17:58:11 (4476): Disabling USB Support for VM. 2018-02-09 17:58:12 (4476): Disabling COM Port Support for VM. 2018-02-09 17:58:13 (4476): Disabling LPT Port Support for VM. 2018-02-09 17:58:15 (4476): Disabling Audio Support for VM. 2018-02-09 17:58:16 (4476): Disabling Clipboard Support for VM. 2018-02-09 17:58:18 (4476): Disabling Drag and Drop Support for VM. 2018-02-09 17:58:19 (4476): Adding storage controller(s) to VM. 2018-02-09 17:58:20 (4476): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso) 2018-02-09 17:58:22 (4476): Adding VirtualBox Guest Additions to VM. 2018-02-09 17:58:24 (4476): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2018-02-09 17:58:26 (4476): Enabling shared directory for VM. 2018-02-09 17:58:50 (4476): Starting VM. (boinc_633b9e660e8c13fc, slot#36) 2018-02-09 19:30:56 (4476): VM failed to start. 2018-02-09 19:31:05 (4476): Powering off VM. 2018-02-09 19:31:12 (4476): Deregistering VM. (boinc_633b9e660e8c13fc, slot#36) 2018-02-09 19:31:37 (4476): CreateProcess failed! (1450). 2018-02-09 19:32:17 (4476): Removing network bandwidth throttle group from VM. 2018-02-09 19:32:22 (4476): CreateProcess failed! (1450). 2018-02-09 19:32:27 (4476): Removing storage controller(s) from VM. 2018-02-09 19:32:31 (4476): CreateProcess failed! (1450). 2018-02-09 19:32:43 (4476): Removing VM from VirtualBox. 2018-02-09 19:38:29 (4476): Removing virtual ISO 9660 disk from VirtualBox. Hypervisor System Log: VM Execution Log: VM Startup Log: VM Trace Log: SCSI Controllers: 8 Maximum SCSI Port count: 16 Maximum Devices per SCSI Port: 1 Maximum SAS PIIX3 Controllers: 1 Maximum SAS ICH9 Controllers: 8 Maximum SAS Port count: 255 Maximum Devices per SAS Port: 1 Maximum NVMe PIIX3 Controllers: 1 Maximum NVMe ICH9 Controllers: 8 Maximum NVMe Port count: 255 Maximum Devices per NVMe Port: 1 Maximum PIIX3 Floppy Controllers:1 Maximum ICH9 Floppy Controllers: 1 Maximum Floppy Port count: 1 Maximum Devices per Floppy Port: 2 Default machine folder: C:\Users\zombie67\VirtualBox VMs Raw-mode Supported: yes Exclusive HW virtualization use: off Default hard disk format: VDI VRDE auth library: VBoxAuth Webservice auth. library: VBoxAuth Remote desktop ExtPack: Oracle VM VirtualBox Extension Pack Log history count: 3 Default frontend: Default audio driver: DirectSound Autostart database path: Default Guest Additions ISO: C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso Logging Level: all 2018-02-09 17:57:52 (4476): Command: VBoxManage -q list hostinfo Exit Code: 0 Output: Host Information: Host time: 2018-02-10T01:57:51.862000000Z Processor online count: 12 Processor count: 12 Processor online core count: 6 Processor core count: 6 Processor supports HW virtualization: yes Processor supports PAE: yes Processor supports long mode: yes Processor supports nested paging: yes Processor#0 speed: unknown Processor#0 description: Intel(R) Core(TM) i7-3930K CPU @ 3.20GHz Processor#1 speed: unknown Processor#1 description: Intel(R) Core(TM) i7-3930K CPU @ 3.20GHz Processor#2 speed: unknown Processor#2 description: Intel(R) Core(TM) i7-3930K CPU @ 3.20GHz Processor#3 speed: unknown Processor#3 description: Intel(R) Core(TM) i7-3930K CPU @ 3.20GHz Processor#4 speed: unknown Processor#4 description: Intel(R) Core(TM) i7-3930K CPU @ 3.20GHz Processor#5 speed: unknown Processor#5 description: Intel(R) Core(TM) i7-3930K CPU @ 3.20GHz Processor#6 speed: unknown Processor#6 description: Intel(R) Core(TM) i7-3930K CPU @ 3.20GHz Processor#7 speed: unknown Processor#7 description: Intel(R) Core(TM) i7-3930K CPU @ 3.20GHz Processor#8 speed: unknown Processor#8 description: Intel(R) Core(TM) i7-3930K CPU @ 3.20GHz Processor#9 speed: unknown Processor#9 description: Intel(R) Core(TM) i7-3930K CPU @ 3.20GHz Processor#10 speed: unknown Processor#10 description: Intel(R) Core(TM) i7-3930K CPU @ 3.20GHz Processor#11 speed: unknown Processor#11 description: Intel(R) Core(TM) i7-3930K CPU @ 3.20GHz Memory size: 32717 MByte Memory available: 7089 MByte Operating system: Windows 7 Operating system version: 6.1.7601sp1 2018-02-09 17:57:54 (4476): Command: VBoxManage -q showvminfo "boinc_633b9e660e8c13fc" --machinereadable Exit Code: -2135228415 Output: VBoxManage.exe: error: Could not find a registered machine named 'boinc_633b9e660e8c13fc' VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2834 of file VBoxManageInfo.cpp 2018-02-09 17:57:56 (4476): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\36/vm_image.vdi" Exit Code: -2135228412 Output: VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\36\vm_image.vdi' (VERR_FILE_NOT_FOUND) VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 179 of file VBoxManageDisk.cpp 2018-02-09 17:58:00 (4476): Command: VBoxManage -q createvm --name "boinc_633b9e660e8c13fc" --basefolder "C:\ProgramData\BOINC\slots\36" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_633b9e660e8c13fc' is created and registered. UUID: 17355734-d8d7-43ed-93c3-57dc65575e71 Settings file: 'C:\ProgramData\BOINC\slots\36\boinc_633b9e660e8c13fc\boinc_633b9e660e8c13fc.vbox' 2018-02-09 17:58:01 (4476): Command: VBoxManage -q modifyvm "boinc_633b9e660e8c13fc" --description "06462618_076_0" Exit Code: 0 Output: 2018-02-09 17:58:03 (4476): Command: VBoxManage -q modifyvm "boinc_633b9e660e8c13fc" --memory 3072 Exit Code: 0 Output: 2018-02-09 17:58:05 (4476): Command: VBoxManage -q modifyvm "boinc_633b9e660e8c13fc" --cpus 1 Exit Code: 0 Output: 2018-02-09 17:58:07 (4476): Command: VBoxManage -q modifyvm "boinc_633b9e660e8c13fc" --acpi on --ioapic on Exit Code: 0 Output: 2018-02-09 17:58:09 (4476): Command: VBoxManage -q modifyvm "boinc_633b9e660e8c13fc" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2018-02-09 17:58:10 (4476): Command: VBoxManage -q modifyvm "boinc_633b9e660e8c13fc" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2018-02-09 17:58:11 (4476): Command: VBoxManage -q modifyvm "boinc_633b9e660e8c13fc" --cableconnected1 on Exit Code: 0 Output: 2018-02-09 17:58:12 (4476): Command: VBoxManage -q modifyvm "boinc_633b9e660e8c13fc" --usb off Exit Code: 0 Output: 2018-02-09 17:58:13 (4476): Command: VBoxManage -q modifyvm "boinc_633b9e660e8c13fc" --uart1 off --uart2 off Exit Code: 0 Output: 2018-02-09 17:58:15 (4476): Command: VBoxManage -q modifyvm "boinc_633b9e660e8c13fc" --lpt1 off --lpt2 off Exit Code: 0 Output: 2018-02-09 17:58:16 (4476): Command: VBoxManage -q modifyvm "boinc_633b9e660e8c13fc" --audio none Exit Code: 0 Output: 2018-02-09 17:58:18 (4476): Command: VBoxManage -q modifyvm "boinc_633b9e660e8c13fc" --clipboard disabled Exit Code: 0 Output: 2018-02-09 17:58:19 (4476): Command: VBoxManage -q modifyvm "boinc_633b9e660e8c13fc" --draganddrop disabled Exit Code: 0 Output: 2018-02-09 17:58:20 (4476): Command: VBoxManage -q storagectl "boinc_633b9e660e8c13fc" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2018-02-09 17:58:22 (4476): Command: VBoxManage -q storageattach "boinc_633b9e660e8c13fc" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\ProgramData\BOINC\slots\36/vm_isocontext.iso" Exit Code: 0 Output: 2018-02-09 17:58:24 (4476): Command: VBoxManage -q storageattach "boinc_633b9e660e8c13fc" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2018-02-09 17:58:26 (4476): Command: VBoxManage -q bandwidthctl "boinc_633b9e660e8c13fc" add "boinc_633b9e660e8c13fc_net" --type network --limit 1024G Exit Code: 0 Output: 2018-02-09 17:58:43 (4476): Command: VBoxManage -q sharedfolder add "boinc_633b9e660e8c13fc" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\36/shared" Exit Code: 0 Output: 2018-02-09 17:58:54 (4476): Command: VBoxManage -q startvm "boinc_633b9e660e8c13fc" --type headless Exit Code: 0 Output: Waiting for VM "boinc_633b9e660e8c13fc" to power on... VM "boinc_633b9e660e8c13fc" has been successfully started. 2018-02-09 19:32:12 (4476): Command: VBoxManage -q snapshot "boinc_633b9e660e8c13fc" list Exit Code: -108 Output: 2018-02-09 19:32:26 (4476): Command: VBoxManage -q bandwidthctl "boinc_633b9e660e8c13fc" remove "boinc_633b9e660e8c13fc_net" Exit Code: -108 Output: 2018-02-09 19:32:31 (4476): Command: VBoxManage -q storagectl "boinc_633b9e660e8c13fc" --name "Hard Disk Controller" --remove Exit Code: -108 Output: 2018-02-09 19:36:33 (4476): Command: VBoxManage -q unregistervm "boinc_633b9e660e8c13fc" --delete Exit Code: -182 Output: 2018-02-09 19:41:16 (4476): Command: VBoxManage -q closemedium dvd "C:\ProgramData\BOINC\slots\36/vm_isocontext.iso" --delete Exit Code: -182 Output: 19:46:21 (4476): called boinc_finish(-182) </stderr_txt> ]]>
©2024 COPYRIGHT 2017-2018 NCN