Task 2632887

Name 07249852_040_0
Workunit 1985330
Created 13 Jun 2019, 2:33:00 UTC
Sent 13 Jun 2019, 16:59:08 UTC
Report deadline 18 Jun 2019, 16:59:08 UTC
Received 13 Jun 2019, 19:14:52 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status 1 (0x00000001) Unknown error code
Computer ID 2174
Run time 35 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 4.05 GFLOPS
Application version boinc2docker v1.12 (vbox64_mt)
windows_x86_64
Peak working set size 10.34 MB
Peak swap size 5.43 MB
Peak disk usage 499.02 MB

Stderr output

<core_client_version>7.14.2</core_client_version>
<![CDATA[
<message>
Onjuiste functie.
 (0x1) - exit code 1 (0x1)</message>
<stderr_txt>
2019-06-13 19:22:13 (14212): vboxwrapper (7.9.26200): starting
2019-06-13 19:22:15 (14212): Feature: Checkpoint interval offset (250 seconds)
2019-06-13 19:22:15 (14212): Detected: VirtualBox VboxManage Interface (Version: 6.0.0)
2019-06-13 19:22:17 (14212): Detected: Minimum checkpoint interval (600.000000 seconds)
2019-06-13 19:22:19 (14212): Create VM. (boinc_75860a63c5acb479, slot#1)
2019-06-13 19:22:19 (14212): Updating drive controller type and model for desired configuration.
2019-06-13 19:22:21 (14212): Setting Memory Size for VM. (3072MB)
2019-06-13 19:22:22 (14212): Setting CPU Count for VM. (1)
2019-06-13 19:22:23 (14212): Setting Chipset Options for VM.
2019-06-13 19:22:25 (14212): Setting Boot Options for VM.
2019-06-13 19:22:26 (14212): Setting Network Configuration for NAT.
2019-06-13 19:22:27 (14212): Enabling VM Network Access.
2019-06-13 19:22:28 (14212): Disabling USB Support for VM.
2019-06-13 19:22:29 (14212): Disabling COM Port Support for VM.
2019-06-13 19:22:30 (14212): Disabling LPT Port Support for VM.
2019-06-13 19:22:30 (14212): Disabling Audio Support for VM.
2019-06-13 19:22:31 (14212): Disabling Clipboard Support for VM.
2019-06-13 19:22:31 (14212): Disabling Drag and Drop Support for VM.
2019-06-13 19:22:31 (14212): Adding storage controller(s) to VM.
2019-06-13 19:22:31 (14212): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso)
2019-06-13 19:22:32 (14212): Adding VirtualBox Guest Additions to VM.
2019-06-13 19:22:32 (14212): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2019-06-13 19:22:32 (14212): Enabling shared directory for VM.
2019-06-13 19:22:33 (14212): Starting VM using VboxManage interface. (boinc_75860a63c5acb479, slot#1)
2019-06-13 19:22:37 (14212): Error in start VM for VM: 1
Command:
VBoxManage -q startvm "boinc_75860a63c5acb479" --type headless
Output:
Waiting for VM "boinc_75860a63c5acb479" to power on...
VBoxManage.exe: error: The virtual machine 'boinc_75860a63c5acb479' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'D:\BOINC\slots\1\boinc_75860a63c5acb479\Logs\VBoxHardening.log'
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine

2019-06-13 19:22:37 (14212): VM failed to start.
2019-06-13 19:22:37 (14212): Could not start 
2019-06-13 19:22:37 (14212): Powering off VM.
2019-06-13 19:22:37 (14212): Deregistering VM. (boinc_75860a63c5acb479, slot#1)
2019-06-13 19:22:37 (14212): Removing network bandwidth throttle group from VM.
2019-06-13 19:22:37 (14212): Removing VM from VirtualBox.
2019-06-13 19:22:38 (14212): Removing virtual ISO 9660 disk from VirtualBox.

    Hypervisor System Log:

00:00:18.469005          Saving settings file "C:\Users\Lucas\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:18.480707          Saving settings file "D:\BOINC\slots\1\boinc_75860a63c5acb479\boinc_75860a63c5acb479.vbox" with version "1.16-windows"
00:00:18.552560          Saving settings file "D:\BOINC\slots\4\boinc_a1c3df90faaa6487\boinc_a1c3df90faaa6487.vbox" with version "1.16-windows"
00:00:18.737322          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:18.740763          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:18.741014          Saving settings file "C:\Users\Lucas\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:18.750652          Saving settings file "C:\Users\Lucas\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:18.759649          Saving settings file "D:\BOINC\slots\1\boinc_75860a63c5acb479\boinc_75860a63c5acb479.vbox" with version "1.16-windows"
00:00:18.806050          Saving settings file "D:\BOINC\slots\4\boinc_a1c3df90faaa6487\boinc_a1c3df90faaa6487.vbox" with version "1.16-windows"
00:00:19.004452          Saving settings file "D:\BOINC\slots\1\boinc_75860a63c5acb479\boinc_75860a63c5acb479.vbox" with version "1.16-windows"
00:00:19.068074          Saving settings file "D:\BOINC\slots\4\boinc_a1c3df90faaa6487\boinc_a1c3df90faaa6487.vbox" with version "1.16-windows"
00:00:19.276283          Saving settings file "D:\BOINC\slots\1\boinc_75860a63c5acb479\boinc_75860a63c5acb479.vbox" with version "1.16-windows"
00:00:19.388140          Saving settings file "D:\BOINC\slots\4\boinc_a1c3df90faaa6487\boinc_a1c3df90faaa6487.vbox" with version "1.16-windows"
00:00:19.543878          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:19.544081          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:19.557527          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:19.881337          Saving settings file "D:\BOINC\slots\4\boinc_a1c3df90faaa6487\boinc_a1c3df90faaa6487.vbox" with version "1.16-windows"
00:00:20.094590          Saving settings file "D:\BOINC\slots\4\boinc_a1c3df90faaa6487\boinc_a1c3df90faaa6487.vbox" with version "1.16-windows"
00:00:20.377438          Saving settings file "D:\BOINC\slots\4\boinc_a1c3df90faaa6487\boinc_a1c3df90faaa6487.vbox" with version "1.16-windows"
00:00:20.646525          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:20.649395          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:20.649639          Saving settings file "C:\Users\Lucas\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:20.660743          Saving settings file "C:\Users\Lucas\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:20.670312          Saving settings file "D:\BOINC\slots\4\boinc_a1c3df90faaa6487\boinc_a1c3df90faaa6487.vbox" with version "1.16-windows"
00:00:21.165991          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:21.166660          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:21.167365          Saving settings file "D:\BOINC\slots\4\boinc_a1c3df90faaa6487\boinc_a1c3df90faaa6487.vbox" with version "1.16-windows"
00:00:21.442475          Saving settings file "D:\BOINC\slots\4\boinc_a1c3df90faaa6487\boinc_a1c3df90faaa6487.vbox" with version "1.16-windows"
00:00:21.697118          Saving settings file "D:\BOINC\slots\4\boinc_a1c3df90faaa6487\boinc_a1c3df90faaa6487.vbox" with version "1.16-windows"
00:00:21.966157          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:21.966343          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:21.978671          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:23.701572 Watcher  ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={MachineWrap} aText={The virtual machine 'boinc_75860a63c5acb479' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'D:\BOINC\slots\1\boinc_75860a63c5acb479\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0
00:00:23.893427          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:24.066510          Saving settings file "D:\BOINC\slots\1\boinc_75860a63c5acb479\boinc_75860a63c5acb479.vbox" with version "1.16-windows"
00:00:24.315070          Saving settings file "C:\Users\Lucas\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:25.845623 Watcher  ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={MachineWrap} aText={The virtual machine 'boinc_a1c3df90faaa6487' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'D:\BOINC\slots\4\boinc_a1c3df90faaa6487\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0
00:00:26.007053          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:26.164051          Saving settings file "D:\BOINC\slots\4\boinc_a1c3df90faaa6487\boinc_a1c3df90faaa6487.vbox" with version "1.16-windows"
00:00:26.433976          Saving settings file "C:\Users\Lucas\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:31.705534 main     VirtualBox: object deletion starts
00:00:31.708275 Watcher  ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0
00:00:31.708499 main     VirtualBox: object deleted

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

:  1
Maximum ICH9 SATA Controllers:   8
Maximum SATA Port count:         30
Maximum Devices per SATA Port:   1
Maximum PIIX3 SCSI Controllers:  1
Maximum ICH9 SCSI Controllers:   8
Maximum SCSI Port count:         16
Maximum Devices per SCSI Port:   1
Maximum SAS PIIX3 Controllers:   1
Maximum SAS ICH9 Controllers:    8
Maximum SAS Port count:          255
Maximum Devices per SAS Port:    1
Maximum NVMe PIIX3 Controllers:  1
Maximum NVMe ICH9 Controllers:   8
Maximum NVMe Port count:         255
Maximum Devices per NVMe Port:   1
Maximum PIIX3 Floppy Controllers:1
Maximum ICH9 Floppy Controllers: 1
Maximum Floppy Port count:       1
Maximum Devices per Floppy Port: 2
Default machine folder:          C:\Users\Lucas\VirtualBox VMs
Raw-mode Supported:              yes
Exclusive HW virtualization use: off
Default hard disk format:        VDI
VRDE auth library:               VBoxAuth
Webservice auth. library:        VBoxAuth
Remote desktop ExtPack:          
Log history count:               3
Default frontend:                
Default audio driver:            DirectSound
Autostart database path:         
Default Guest Additions ISO:     B:\Virtual Box/VBoxGuestAdditions.iso
Logging Level:                   all
Proxy Mode:                      System
Proxy URL:                       

2019-06-13 19:22:17 (14212): 
Command: VBoxManage -q list hostinfo 
Exit Code: 0
Output:
Host Information:

Host time: 2019-06-13T17:22:16.747000000Z
Processor online count: 8
Processor count: 8
Processor online core count: 4
Processor core count: 4
Processor supports HW virtualization: yes
Processor supports PAE: yes
Processor supports long mode: yes
Processor supports nested paging: no
Processor#0 speed: unknown
Processor#0 description: Intel(R) Core(TM) i7-7700HQ CPU @ 2.80GHz
Processor#1 speed: unknown
Processor#1 description: Intel(R) Core(TM) i7-7700HQ CPU @ 2.80GHz
Processor#2 speed: unknown
Processor#2 description: Intel(R) Core(TM) i7-7700HQ CPU @ 2.80GHz
Processor#3 speed: unknown
Processor#3 description: Intel(R) Core(TM) i7-7700HQ CPU @ 2.80GHz
Processor#4 speed: unknown
Processor#4 description: Intel(R) Core(TM) i7-7700HQ CPU @ 2.80GHz
Processor#5 speed: unknown
Processor#5 description: Intel(R) Core(TM) i7-7700HQ CPU @ 2.80GHz
Processor#6 speed: unknown
Processor#6 description: Intel(R) Core(TM) i7-7700HQ CPU @ 2.80GHz
Processor#7 speed: unknown
Processor#7 description: Intel(R) Core(TM) i7-7700HQ CPU @ 2.80GHz
Memory size: 16324 MByte
Memory available: 9055 MByte
Operating system: Windows 10
Operating system version: 10.0.17134

2019-06-13 19:22:19 (14212): 
Command: VBoxManage -q showvminfo "boinc_75860a63c5acb479" --machinereadable 
Exit Code: -2135228415
Output:
VBoxManage.exe: error: Could not find a registered machine named 'boinc_75860a63c5acb479'
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown
VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2621 of file VBoxManageInfo.cpp

2019-06-13 19:22:19 (14212): 
Command: VBoxManage -q showhdinfo "D:\BOINC\slots\1/vm_image.vdi" 
Exit Code: -2135228412
Output:
VBoxManage.exe: error: Could not find file for the medium 'D:\BOINC\slots\1\vm_image.vdi' (VERR_FILE_NOT_FOUND)
VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp

2019-06-13 19:22:20 (14212): 
Command: VBoxManage -q createvm --name "boinc_75860a63c5acb479" --basefolder "D:\BOINC\slots\1" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_75860a63c5acb479' is created and registered.
UUID: ea68528b-bba8-4b26-9ead-14cea5a916d2
Settings file: 'D:\BOINC\slots\1\boinc_75860a63c5acb479\boinc_75860a63c5acb479.vbox'

2019-06-13 19:22:21 (14212): 
Command: VBoxManage -q modifyvm "boinc_75860a63c5acb479" --description "07249852_040_0" 
Exit Code: 0
Output:

2019-06-13 19:22:22 (14212): 
Command: VBoxManage -q modifyvm "boinc_75860a63c5acb479" --memory 3072 
Exit Code: 0
Output:

2019-06-13 19:22:23 (14212): 
Command: VBoxManage -q modifyvm "boinc_75860a63c5acb479" --cpus 1 
Exit Code: 0
Output:

2019-06-13 19:22:25 (14212): 
Command: VBoxManage -q modifyvm "boinc_75860a63c5acb479" --acpi on --ioapic on 
Exit Code: 0
Output:

2019-06-13 19:22:26 (14212): 
Command: VBoxManage -q modifyvm "boinc_75860a63c5acb479" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2019-06-13 19:22:27 (14212): 
Command: VBoxManage -q modifyvm "boinc_75860a63c5acb479" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2019-06-13 19:22:28 (14212): 
Command: VBoxManage -q modifyvm "boinc_75860a63c5acb479" --cableconnected1 on 
Exit Code: 0
Output:

2019-06-13 19:22:29 (14212): 
Command: VBoxManage -q modifyvm "boinc_75860a63c5acb479" --usb off 
Exit Code: 0
Output:

2019-06-13 19:22:30 (14212): 
Command: VBoxManage -q modifyvm "boinc_75860a63c5acb479" --uart1 off --uart2 off 
Exit Code: 0
Output:

2019-06-13 19:22:30 (14212): 
Command: VBoxManage -q modifyvm "boinc_75860a63c5acb479" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2019-06-13 19:22:31 (14212): 
Command: VBoxManage -q modifyvm "boinc_75860a63c5acb479" --audio none 
Exit Code: 0
Output:

2019-06-13 19:22:31 (14212): 
Command: VBoxManage -q modifyvm "boinc_75860a63c5acb479" --clipboard disabled 
Exit Code: 0
Output:

2019-06-13 19:22:31 (14212): 
Command: VBoxManage -q modifyvm "boinc_75860a63c5acb479" --draganddrop disabled 
Exit Code: 0
Output:

2019-06-13 19:22:31 (14212): 
Command: VBoxManage -q storagectl "boinc_75860a63c5acb479" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2019-06-13 19:22:32 (14212): 
Command: VBoxManage -q storageattach "boinc_75860a63c5acb479" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "D:\BOINC\slots\1/vm_isocontext.iso" 
Exit Code: 0
Output:

2019-06-13 19:22:32 (14212): 
Command: VBoxManage -q storageattach "boinc_75860a63c5acb479" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "B:\Virtual Box/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2019-06-13 19:22:32 (14212): 
Command: VBoxManage -q bandwidthctl "boinc_75860a63c5acb479" add "boinc_75860a63c5acb479_net" --type network --limit 1024G 
Exit Code: 0
Output:

2019-06-13 19:22:33 (14212): 
Command: VBoxManage -q sharedfolder add "boinc_75860a63c5acb479" --name "shared" --hostpath "D:\BOINC\slots\1/shared"
Exit Code: 0
Output:

2019-06-13 19:22:37 (14212): 
Command: VBoxManage -q startvm "boinc_75860a63c5acb479" --type headless
Exit Code: 1
Output:
Waiting for VM "boinc_75860a63c5acb479" to power on...
VBoxManage.exe: error: The virtual machine 'boinc_75860a63c5acb479' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'D:\BOINC\slots\1\boinc_75860a63c5acb479\Logs\VBoxHardening.log'
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine

2019-06-13 19:22:37 (14212): 
Command: VBoxManage -q snapshot "boinc_75860a63c5acb479" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2019-06-13 19:22:37 (14212): 
Command: VBoxManage -q bandwidthctl "boinc_75860a63c5acb479" remove "boinc_75860a63c5acb479_net" 
Exit Code: 0
Output:

2019-06-13 19:22:38 (14212): 
Command: VBoxManage -q unregistervm "boinc_75860a63c5acb479" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

2019-06-13 19:22:38 (14212): 
Command: VBoxManage -q closemedium dvd "D:\BOINC\slots\1/vm_isocontext.iso" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

19:22:45 (14212): called boinc_finish(1)

</stderr_txt>
]]>


©2024 COPYRIGHT 2017-2018 NCN