Name | 07816068_33_0 |
Workunit | 6755937 |
Created | 22 Jun 2020, 23:15:12 UTC |
Sent | 23 Jun 2020, 2:45:04 UTC |
Report deadline | 28 Jun 2020, 2:45:04 UTC |
Received | 25 Jun 2020, 3:48:00 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | 1 (0x00000001) Unknown error code |
Computer ID | 7535 |
Run time | 18 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 3.47 GFLOPS |
Application version | boinc2docker v1.12 (vbox64_mt) windows_x86_64 |
Peak working set size | 10.87 MB |
Peak swap size | 6.20 MB |
Peak disk usage | 230.25 MB |
<core_client_version>7.16.7</core_client_version> <![CDATA[ <message> Incorrect function. (0x1) - exit code 1 (0x1)</message> <stderr_txt> 2020-06-24 23:54:14 (7892): vboxwrapper (7.9.26200): starting 2020-06-24 23:54:16 (7892): Feature: Checkpoint interval offset (472 seconds) 2020-06-24 23:54:16 (7892): Detected: VirtualBox VboxManage Interface (Version: 6.0.22) 2020-06-24 23:54:17 (7892): Detected: Minimum checkpoint interval (600.000000 seconds) 2020-06-24 23:54:17 (7892): Create VM. (boinc_a066dc74162268e7, slot#9) 2020-06-24 23:54:17 (7892): Updating drive controller type and model for desired configuration. 2020-06-24 23:54:18 (7892): Setting Memory Size for VM. (3072MB) 2020-06-24 23:54:18 (7892): Setting CPU Count for VM. (1) 2020-06-24 23:54:18 (7892): Setting Chipset Options for VM. 2020-06-24 23:54:19 (7892): Setting Boot Options for VM. 2020-06-24 23:54:19 (7892): Setting Network Configuration for NAT. 2020-06-24 23:54:19 (7892): Enabling VM Network Access. 2020-06-24 23:54:19 (7892): Disabling USB Support for VM. 2020-06-24 23:54:20 (7892): Disabling COM Port Support for VM. 2020-06-24 23:54:20 (7892): Disabling LPT Port Support for VM. 2020-06-24 23:54:20 (7892): Disabling Audio Support for VM. 2020-06-24 23:54:21 (7892): Disabling Clipboard Support for VM. 2020-06-24 23:54:21 (7892): Disabling Drag and Drop Support for VM. 2020-06-24 23:54:21 (7892): Adding storage controller(s) to VM. 2020-06-24 23:54:21 (7892): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso) 2020-06-24 23:54:22 (7892): Adding VirtualBox Guest Additions to VM. 2020-06-24 23:54:22 (7892): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2020-06-24 23:54:22 (7892): Enabling shared directory for VM. 2020-06-24 23:54:23 (7892): Starting VM using VboxManage interface. (boinc_a066dc74162268e7, slot#9) 2020-06-24 23:54:23 (7892): Error in start VM for VM: 1 Command: VBoxManage -q startvm "boinc_a066dc74162268e7" --type headless Output: Waiting for VM "boinc_a066dc74162268e7" to power on... VBoxManage.exe: error: The virtual machine 'boinc_a066dc74162268e7' has terminated unexpectedly during startup with exit code 1 (0x1) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine 2020-06-24 23:54:23 (7892): VM failed to start. 2020-06-24 23:54:23 (7892): Could not start 2020-06-24 23:54:23 (7892): Powering off VM. 2020-06-24 23:54:23 (7892): Deregistering VM. (boinc_a066dc74162268e7, slot#9) 2020-06-24 23:54:23 (7892): Removing network bandwidth throttle group from VM. 2020-06-24 23:54:23 (7892): Removing VM from VirtualBox. 2020-06-24 23:54:24 (7892): Removing virtual ISO 9660 disk from VirtualBox. Hypervisor System Log: 00:00:01.011980 Loading settings file "C:\ProgramData\BOINC\slots\6\boinc_3ac21894eda5a6ac\boinc_3ac21894eda5a6ac.vbox" with version "1.16-windows" 00:00:01.013481 Loading settings file "C:\ProgramData\BOINC\slots\5\boinc_3b49e043f9134056\boinc_3b49e043f9134056.vbox" with version "1.16-windows" 00:00:01.014696 Loading settings file "C:\ProgramData\BOINC\slots\15\boinc_3c95a4b52e1bc9cb\boinc_3c95a4b52e1bc9cb.vbox" with version "1.16-windows" 00:00:01.016119 Loading settings file "C:\ProgramData\BOINC\slots\16\boinc_3fd927bdc2bd0d74\boinc_3fd927bdc2bd0d74.vbox" with version "1.16-windows" 00:00:01.017402 VirtualBox: object created 00:00:01.720654 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={Could not find a registered machine named 'boinc_a066dc74162268e7'}, preserve=false aResultDetail=0 00:00:02.013054 ERROR [COM]: aRC=VBOX_E_FILE_ERROR (0x80bb0004) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Could not find file for the medium 'C:\ProgramData\BOINC\slots\9\vm_image.vdi' (VERR_FILE_NOT_FOUND)}, preserve=false aResultDetail=-102 00:00:02.313637 Saving settings file "C:\ProgramData\BOINC\slots\9\boinc_a066dc74162268e7\boinc_a066dc74162268e7.vbox" with version "1.16-windows" 00:00:02.349528 Saving settings file "C:\Users\Anyone\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:02.595901 Saving settings file "C:\ProgramData\BOINC\slots\9\boinc_a066dc74162268e7\boinc_a066dc74162268e7.vbox" with version "1.16-windows" 00:00:02.874012 Saving settings file "C:\ProgramData\BOINC\slots\9\boinc_a066dc74162268e7\boinc_a066dc74162268e7.vbox" with version "1.16-windows" 00:00:03.159869 Saving settings file "C:\ProgramData\BOINC\slots\9\boinc_a066dc74162268e7\boinc_a066dc74162268e7.vbox" with version "1.16-windows" 00:00:03.453377 Saving settings file "C:\ProgramData\BOINC\slots\9\boinc_a066dc74162268e7\boinc_a066dc74162268e7.vbox" with version "1.16-windows" 00:00:03.762113 Saving settings file "C:\ProgramData\BOINC\slots\9\boinc_a066dc74162268e7\boinc_a066dc74162268e7.vbox" with version "1.16-windows" 00:00:04.050024 Saving settings file "C:\ProgramData\BOINC\slots\9\boinc_a066dc74162268e7\boinc_a066dc74162268e7.vbox" with version "1.16-windows" 00:00:04.331388 Saving settings file "C:\ProgramData\BOINC\slots\9\boinc_a066dc74162268e7\boinc_a066dc74162268e7.vbox" with version "1.16-windows" 00:00:04.622472 Saving settings file "C:\ProgramData\BOINC\slots\9\boinc_a066dc74162268e7\boinc_a066dc74162268e7.vbox" with version "1.16-windows" 00:00:04.905820 Saving settings file "C:\ProgramData\BOINC\slots\9\boinc_a066dc74162268e7\boinc_a066dc74162268e7.vbox" with version "1.16-windows" 00:00:05.187853 Saving settings file "C:\ProgramData\BOINC\slots\9\boinc_a066dc74162268e7\boinc_a066dc74162268e7.vbox" with version "1.16-windows" 00:00:05.465539 Saving settings file "C:\ProgramData\BOINC\slots\9\boinc_a066dc74162268e7\boinc_a066dc74162268e7.vbox" with version "1.16-windows" 00:00:05.750080 Saving settings file "C:\ProgramData\BOINC\slots\9\boinc_a066dc74162268e7\boinc_a066dc74162268e7.vbox" with version "1.16-windows" 00:00:06.033489 Saving settings file "C:\ProgramData\BOINC\slots\9\boinc_a066dc74162268e7\boinc_a066dc74162268e7.vbox" with version "1.16-windows" 00:00:06.329150 Saving settings file "C:\ProgramData\BOINC\slots\9\boinc_a066dc74162268e7\boinc_a066dc74162268e7.vbox" with version "1.16-windows" 00:00:06.609281 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:06.612030 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:06.612453 Saving settings file "C:\Users\Anyone\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:06.691011 Saving settings file "C:\Users\Anyone\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:06.714341 Saving settings file "C:\ProgramData\BOINC\slots\9\boinc_a066dc74162268e7\boinc_a066dc74162268e7.vbox" with version "1.16-windows" 00:00:06.887625 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:06.888363 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:06.889294 Saving settings file "C:\ProgramData\BOINC\slots\9\boinc_a066dc74162268e7\boinc_a066dc74162268e7.vbox" with version "1.16-windows" 00:00:07.179692 Saving settings file "C:\ProgramData\BOINC\slots\9\boinc_a066dc74162268e7\boinc_a066dc74162268e7.vbox" with version "1.16-windows" 00:00:07.452349 Saving settings file "C:\ProgramData\BOINC\slots\9\boinc_a066dc74162268e7\boinc_a066dc74162268e7.vbox" with version "1.16-windows" 00:00:07.737027 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.737267 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.748157 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:08.032829 Watcher ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={MachineWrap} aText={The virtual machine 'boinc_a066dc74162268e7' has terminated unexpectedly during startup with exit code 1 (0x1)}, preserve=false aResultDetail=0 00:00:08.033545 Watcher Reaper: Pid 100 (64) exited normally: 1 (0x1) 00:00:08.164633 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:08.267401 Saving settings file "C:\ProgramData\BOINC\slots\9\boinc_a066dc74162268e7\boinc_a066dc74162268e7.vbox" with version "1.16-windows" 00:00:08.542298 Saving settings file "C:\Users\Anyone\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:13.841993 main VirtualBox: object deletion starts 00:00:13.842086 main ERROR [COM]: aRC=VBOX_E_OBJECT_IN_USE (0x80bb000c) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Medium 'C:\Users\Anyone\VirtualBox VMs\VirtualBox\VirtualBox.vdi' cannot be closed because it is still attached to 1 virtual machines}, preserve=false aResultDetail=0 00:00:13.846824 main HostDnsMonitor: shutting down ... 00:00:13.846930 main HostDnsMonitor: shut down 00:00:13.848437 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:13.848698 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: ideo RAM size: 256 Megabytes Maximum guest monitor count: 64 Minimum guest CPU count: 1 Maximum guest CPU count: 32 Virtual disk limit (info): 2199022206976 Bytes Maximum Serial Port count: 4 Maximum Parallel Port count: 2 Maximum Boot Position: 4 Maximum PIIX3 Network Adapter count: 8 Maximum ICH9 Network Adapter count: 36 Maximum PIIX3 IDE Controllers: 1 Maximum ICH9 IDE Controllers: 1 Maximum IDE Port count: 2 Maximum Devices per IDE Port: 2 Maximum PIIX3 SATA Controllers: 1 Maximum ICH9 SATA Controllers: 8 Maximum SATA Port count: 30 Maximum Devices per SATA Port: 1 Maximum PIIX3 SCSI Controllers: 1 Maximum ICH9 SCSI Controllers: 8 Maximum SCSI Port count: 16 Maximum Devices per SCSI Port: 1 Maximum SAS PIIX3 Controllers: 1 Maximum SAS ICH9 Controllers: 8 Maximum SAS Port count: 255 Maximum Devices per SAS Port: 1 Maximum NVMe PIIX3 Controllers: 1 Maximum NVMe ICH9 Controllers: 8 Maximum NVMe Port count: 255 Maximum Devices per NVMe Port: 1 Maximum PIIX3 Floppy Controllers:1 Maximum ICH9 Floppy Controllers: 1 Maximum Floppy Port count: 1 Maximum Devices per Floppy Port: 2 Default machine folder: C:\Users\Anyone\VirtualBox VMs Raw-mode Supported: yes Exclusive HW virtualization use: off Default hard disk format: VDI VRDE auth library: VBoxAuth Webservice auth. library: VBoxAuth Remote desktop ExtPack: Log history count: 3 Default frontend: Default audio driver: DirectSound Autostart database path: Default Guest Additions ISO: C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso Logging Level: all Proxy Mode: System Proxy URL: 2020-06-24 23:54:17 (7892): Command: VBoxManage -q list hostinfo Exit Code: 0 Output: Host Information: Host time: 2020-06-25T02:24:16.862000000Z Processor online count: 2 Processor count: 2 Processor online core count: 2 Processor core count: 2 Processor supports HW virtualization: no Processor supports PAE: yes Processor supports long mode: yes Processor supports nested paging: no Processor#0 speed: unknown Processor#0 description: Intel(R) Core(TM)2 Duo CPU E7500 @ 2.93GHz Processor#1 speed: unknown Processor#1 description: Intel(R) Core(TM)2 Duo CPU E7500 @ 2.93GHz Memory size: 4017 MByte Memory available: 1712 MByte Operating system: Windows 10 Operating system version: 10.0.19041 2020-06-24 23:54:17 (7892): Command: VBoxManage -q showvminfo "boinc_a066dc74162268e7" --machinereadable Exit Code: -2135228415 Output: VBoxManage.exe: error: Could not find a registered machine named 'boinc_a066dc74162268e7' VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2664 of file VBoxManageInfo.cpp 2020-06-24 23:54:17 (7892): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\9/vm_image.vdi" Exit Code: -2135228412 Output: VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\9\vm_image.vdi' (VERR_FILE_NOT_FOUND) VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp 2020-06-24 23:54:17 (7892): Command: VBoxManage -q createvm --name "boinc_a066dc74162268e7" --basefolder "C:\ProgramData\BOINC\slots\9" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_a066dc74162268e7' is created and registered. UUID: 038f277d-db4a-42e4-903f-f35232a4ca85 Settings file: 'C:\ProgramData\BOINC\slots\9\boinc_a066dc74162268e7\boinc_a066dc74162268e7.vbox' 2020-06-24 23:54:18 (7892): Command: VBoxManage -q modifyvm "boinc_a066dc74162268e7" --description "07816068_33_0" Exit Code: 0 Output: 2020-06-24 23:54:18 (7892): Command: VBoxManage -q modifyvm "boinc_a066dc74162268e7" --memory 3072 Exit Code: 0 Output: 2020-06-24 23:54:18 (7892): Command: VBoxManage -q modifyvm "boinc_a066dc74162268e7" --cpus 1 Exit Code: 0 Output: 2020-06-24 23:54:19 (7892): Command: VBoxManage -q modifyvm "boinc_a066dc74162268e7" --acpi on --ioapic on Exit Code: 0 Output: 2020-06-24 23:54:19 (7892): Command: VBoxManage -q modifyvm "boinc_a066dc74162268e7" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2020-06-24 23:54:19 (7892): Command: VBoxManage -q modifyvm "boinc_a066dc74162268e7" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2020-06-24 23:54:19 (7892): Command: VBoxManage -q modifyvm "boinc_a066dc74162268e7" --cableconnected1 on Exit Code: 0 Output: 2020-06-24 23:54:20 (7892): Command: VBoxManage -q modifyvm "boinc_a066dc74162268e7" --usb off Exit Code: 0 Output: 2020-06-24 23:54:20 (7892): Command: VBoxManage -q modifyvm "boinc_a066dc74162268e7" --uart1 off --uart2 off Exit Code: 0 Output: 2020-06-24 23:54:20 (7892): Command: VBoxManage -q modifyvm "boinc_a066dc74162268e7" --lpt1 off --lpt2 off Exit Code: 0 Output: 2020-06-24 23:54:21 (7892): Command: VBoxManage -q modifyvm "boinc_a066dc74162268e7" --audio none Exit Code: 0 Output: 2020-06-24 23:54:21 (7892): Command: VBoxManage -q modifyvm "boinc_a066dc74162268e7" --clipboard disabled Exit Code: 0 Output: 2020-06-24 23:54:21 (7892): Command: VBoxManage -q modifyvm "boinc_a066dc74162268e7" --draganddrop disabled Exit Code: 0 Output: 2020-06-24 23:54:21 (7892): Command: VBoxManage -q storagectl "boinc_a066dc74162268e7" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2020-06-24 23:54:22 (7892): Command: VBoxManage -q storageattach "boinc_a066dc74162268e7" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\ProgramData\BOINC\slots\9/vm_isocontext.iso" Exit Code: 0 Output: 2020-06-24 23:54:22 (7892): Command: VBoxManage -q storageattach "boinc_a066dc74162268e7" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2020-06-24 23:54:22 (7892): Command: VBoxManage -q bandwidthctl "boinc_a066dc74162268e7" add "boinc_a066dc74162268e7_net" --type network --limit 1024G Exit Code: 0 Output: 2020-06-24 23:54:23 (7892): Command: VBoxManage -q sharedfolder add "boinc_a066dc74162268e7" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\9/shared" Exit Code: 0 Output: 2020-06-24 23:54:23 (7892): Command: VBoxManage -q startvm "boinc_a066dc74162268e7" --type headless Exit Code: 1 Output: Waiting for VM "boinc_a066dc74162268e7" to power on... VBoxManage.exe: error: The virtual machine 'boinc_a066dc74162268e7' has terminated unexpectedly during startup with exit code 1 (0x1) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine 2020-06-24 23:54:23 (7892): Command: VBoxManage -q snapshot "boinc_a066dc74162268e7" list Exit Code: -108 Output: This machine does not have any snapshots 2020-06-24 23:54:23 (7892): Command: VBoxManage -q bandwidthctl "boinc_a066dc74162268e7" remove "boinc_a066dc74162268e7_net" Exit Code: 0 Output: 2020-06-24 23:54:24 (7892): Command: VBoxManage -q unregistervm "boinc_a066dc74162268e7" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 2020-06-24 23:54:24 (7892): Command: VBoxManage -q closemedium dvd "C:\ProgramData\BOINC\slots\9/vm_isocontext.iso" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 23:54:29 (7892): called boinc_finish(1) </stderr_txt> ]]>
©2025 COPYRIGHT 2017-2018 NCN