Task 8370522

Name 07815535_28_1
Workunit 6744754
Created 23 Jun 2020, 2:22:08 UTC
Sent 23 Jun 2020, 2:45:04 UTC
Report deadline 28 Jun 2020, 2:45:04 UTC
Received 25 Jun 2020, 3:48:00 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status 1 (0x00000001) Unknown error code
Computer ID 7535
Run time 17 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 3.47 GFLOPS
Application version boinc2docker v1.12 (vbox64_mt)
windows_x86_64
Peak working set size 10.87 MB
Peak swap size 6.20 MB
Peak disk usage 600.75 MB

Stderr output

<core_client_version>7.16.7</core_client_version>
<![CDATA[
<message>
Incorrect function.
 (0x1) - exit code 1 (0x1)</message>
<stderr_txt>
2020-06-24 23:44:01 (7320): vboxwrapper (7.9.26200): starting
2020-06-24 23:44:03 (7320): Feature: Checkpoint interval offset (438 seconds)
2020-06-24 23:44:03 (7320): Detected: VirtualBox VboxManage Interface (Version: 6.0.22)
2020-06-24 23:44:03 (7320): Detected: Minimum checkpoint interval (600.000000 seconds)
2020-06-24 23:44:04 (7320): Create VM. (boinc_7ef676997328c214, slot#9)
2020-06-24 23:44:04 (7320): Updating drive controller type and model for desired configuration.
2020-06-24 23:44:04 (7320): Setting Memory Size for VM. (3072MB)
2020-06-24 23:44:04 (7320): Setting CPU Count for VM. (1)
2020-06-24 23:44:05 (7320): Setting Chipset Options for VM.
2020-06-24 23:44:05 (7320): Setting Boot Options for VM.
2020-06-24 23:44:05 (7320): Setting Network Configuration for NAT.
2020-06-24 23:44:06 (7320): Enabling VM Network Access.
2020-06-24 23:44:06 (7320): Disabling USB Support for VM.
2020-06-24 23:44:06 (7320): Disabling COM Port Support for VM.
2020-06-24 23:44:06 (7320): Disabling LPT Port Support for VM.
2020-06-24 23:44:07 (7320): Disabling Audio Support for VM.
2020-06-24 23:44:07 (7320): Disabling Clipboard Support for VM.
2020-06-24 23:44:07 (7320): Disabling Drag and Drop Support for VM.
2020-06-24 23:44:08 (7320): Adding storage controller(s) to VM.
2020-06-24 23:44:08 (7320): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso)
2020-06-24 23:44:08 (7320): Adding VirtualBox Guest Additions to VM.
2020-06-24 23:44:08 (7320): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2020-06-24 23:44:09 (7320): Enabling shared directory for VM.
2020-06-24 23:44:09 (7320): Starting VM using VboxManage interface. (boinc_7ef676997328c214, slot#9)
2020-06-24 23:44:09 (7320): Error in start VM for VM: 1
Command:
VBoxManage -q startvm "boinc_7ef676997328c214" --type headless
Output:
Waiting for VM "boinc_7ef676997328c214" to power on...
VBoxManage.exe: error: The virtual machine 'boinc_7ef676997328c214' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\9\boinc_7ef676997328c214\Logs\VBoxHardening.log'
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine

2020-06-24 23:44:09 (7320): VM failed to start.
2020-06-24 23:44:09 (7320): Could not start 
2020-06-24 23:44:09 (7320): Powering off VM.
2020-06-24 23:44:09 (7320): Deregistering VM. (boinc_7ef676997328c214, slot#9)
2020-06-24 23:44:10 (7320): Removing network bandwidth throttle group from VM.
2020-06-24 23:44:10 (7320): Removing VM from VirtualBox.
2020-06-24 23:44:10 (7320): Removing virtual ISO 9660 disk from VirtualBox.

    Hypervisor System Log:

00:00:00.756370          Loading settings file "C:\ProgramData\BOINC\slots\5\boinc_3b49e043f9134056\boinc_3b49e043f9134056.vbox" with version "1.16-windows"
00:00:00.757560          Loading settings file "C:\ProgramData\BOINC\slots\15\boinc_3c95a4b52e1bc9cb\boinc_3c95a4b52e1bc9cb.vbox" with version "1.16-windows"
00:00:00.758729          Loading settings file "C:\ProgramData\BOINC\slots\16\boinc_3fd927bdc2bd0d74\boinc_3fd927bdc2bd0d74.vbox" with version "1.16-windows"
00:00:00.759912          VirtualBox: object created
00:00:01.474174          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={Could not find a registered machine named 'boinc_7ef676997328c214'}, preserve=false aResultDetail=0
00:00:01.761271          ERROR [COM]: aRC=VBOX_E_FILE_ERROR (0x80bb0004) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Could not find file for the medium 'C:\ProgramData\BOINC\slots\9\vm_image.vdi' (VERR_FILE_NOT_FOUND)}, preserve=false aResultDetail=-102
00:00:02.061859          Saving settings file "C:\ProgramData\BOINC\slots\9\boinc_7ef676997328c214\boinc_7ef676997328c214.vbox" with version "1.16-windows"
00:00:02.105022          Saving settings file "C:\Users\Anyone\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:02.348378          Saving settings file "C:\ProgramData\BOINC\slots\9\boinc_7ef676997328c214\boinc_7ef676997328c214.vbox" with version "1.16-windows"
00:00:02.627765          Saving settings file "C:\ProgramData\BOINC\slots\9\boinc_7ef676997328c214\boinc_7ef676997328c214.vbox" with version "1.16-windows"
00:00:02.910627          Saving settings file "C:\ProgramData\BOINC\slots\9\boinc_7ef676997328c214\boinc_7ef676997328c214.vbox" with version "1.16-windows"
00:00:03.189216          Saving settings file "C:\ProgramData\BOINC\slots\9\boinc_7ef676997328c214\boinc_7ef676997328c214.vbox" with version "1.16-windows"
00:00:03.471863          Saving settings file "C:\ProgramData\BOINC\slots\9\boinc_7ef676997328c214\boinc_7ef676997328c214.vbox" with version "1.16-windows"
00:00:03.758789          Saving settings file "C:\ProgramData\BOINC\slots\9\boinc_7ef676997328c214\boinc_7ef676997328c214.vbox" with version "1.16-windows"
00:00:04.057960          Saving settings file "C:\ProgramData\BOINC\slots\9\boinc_7ef676997328c214\boinc_7ef676997328c214.vbox" with version "1.16-windows"
00:00:04.349050          Saving settings file "C:\ProgramData\BOINC\slots\9\boinc_7ef676997328c214\boinc_7ef676997328c214.vbox" with version "1.16-windows"
00:00:04.628676          Saving settings file "C:\ProgramData\BOINC\slots\9\boinc_7ef676997328c214\boinc_7ef676997328c214.vbox" with version "1.16-windows"
00:00:04.908021          Saving settings file "C:\ProgramData\BOINC\slots\9\boinc_7ef676997328c214\boinc_7ef676997328c214.vbox" with version "1.16-windows"
00:00:05.189549          Saving settings file "C:\ProgramData\BOINC\slots\9\boinc_7ef676997328c214\boinc_7ef676997328c214.vbox" with version "1.16-windows"
00:00:05.471131          Saving settings file "C:\ProgramData\BOINC\slots\9\boinc_7ef676997328c214\boinc_7ef676997328c214.vbox" with version "1.16-windows"
00:00:05.759852          Saving settings file "C:\ProgramData\BOINC\slots\9\boinc_7ef676997328c214\boinc_7ef676997328c214.vbox" with version "1.16-windows"
00:00:06.037763          Saving settings file "C:\ProgramData\BOINC\slots\9\boinc_7ef676997328c214\boinc_7ef676997328c214.vbox" with version "1.16-windows"
00:00:06.316447          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.318842          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.319168          Saving settings file "C:\Users\Anyone\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:06.379290          Saving settings file "C:\Users\Anyone\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:06.451311          Saving settings file "C:\ProgramData\BOINC\slots\9\boinc_7ef676997328c214\boinc_7ef676997328c214.vbox" with version "1.16-windows"
00:00:06.598291          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.598979          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.599750          Saving settings file "C:\ProgramData\BOINC\slots\9\boinc_7ef676997328c214\boinc_7ef676997328c214.vbox" with version "1.16-windows"
00:00:06.878048          Saving settings file "C:\ProgramData\BOINC\slots\9\boinc_7ef676997328c214\boinc_7ef676997328c214.vbox" with version "1.16-windows"
00:00:07.157312          Saving settings file "C:\ProgramData\BOINC\slots\9\boinc_7ef676997328c214\boinc_7ef676997328c214.vbox" with version "1.16-windows"
00:00:07.445063          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.445335          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.458011          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:07.770519 Watcher  ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={MachineWrap} aText={The virtual machine 'boinc_7ef676997328c214' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\9\boinc_7ef676997328c214\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0
00:00:07.772791 Watcher  Reaper: Pid 2260 (8d4) exited normally: 1 (0x1)
00:00:07.924537          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:08.034215          Saving settings file "C:\ProgramData\BOINC\slots\9\boinc_7ef676997328c214\boinc_7ef676997328c214.vbox" with version "1.16-windows"
00:00:08.324136          Saving settings file "C:\Users\Anyone\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:13.626241 main     VirtualBox: object deletion starts
00:00:13.626336 main     ERROR [COM]: aRC=VBOX_E_OBJECT_IN_USE (0x80bb000c) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Medium 'C:\Users\Anyone\VirtualBox VMs\VirtualBox\VirtualBox.vdi' cannot be closed because it is still attached to 1 virtual machines}, preserve=false aResultDetail=0
00:00:13.631090 main     HostDnsMonitor: shutting down ...
00:00:13.631174 main     HostDnsMonitor: shut down
00:00:13.632595 Watcher  ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0
00:00:13.632889 main     VirtualBox: object deleted

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

Maximum guest CPU count:         32
Virtual disk limit (info):       2199022206976 Bytes
Maximum Serial Port count:       4
Maximum Parallel Port count:     2
Maximum Boot Position:           4
Maximum PIIX3 Network Adapter count:   8
Maximum ICH9 Network Adapter count:   36
Maximum PIIX3 IDE Controllers:   1
Maximum ICH9 IDE Controllers:    1
Maximum IDE Port count:          2
Maximum Devices per IDE Port:    2
Maximum PIIX3 SATA Controllers:  1
Maximum ICH9 SATA Controllers:   8
Maximum SATA Port count:         30
Maximum Devices per SATA Port:   1
Maximum PIIX3 SCSI Controllers:  1
Maximum ICH9 SCSI Controllers:   8
Maximum SCSI Port count:         16
Maximum Devices per SCSI Port:   1
Maximum SAS PIIX3 Controllers:   1
Maximum SAS ICH9 Controllers:    8
Maximum SAS Port count:          255
Maximum Devices per SAS Port:    1
Maximum NVMe PIIX3 Controllers:  1
Maximum NVMe ICH9 Controllers:   8
Maximum NVMe Port count:         255
Maximum Devices per NVMe Port:   1
Maximum PIIX3 Floppy Controllers:1
Maximum ICH9 Floppy Controllers: 1
Maximum Floppy Port count:       1
Maximum Devices per Floppy Port: 2
Default machine folder:          C:\Users\Anyone\VirtualBox VMs
Raw-mode Supported:              yes
Exclusive HW virtualization use: off
Default hard disk format:        VDI
VRDE auth library:               VBoxAuth
Webservice auth. library:        VBoxAuth
Remote desktop ExtPack:          
Log history count:               3
Default frontend:                
Default audio driver:            DirectSound
Autostart database path:         
Default Guest Additions ISO:     C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso
Logging Level:                   all
Proxy Mode:                      System
Proxy URL:                       

2020-06-24 23:44:03 (7320): 
Command: VBoxManage -q list hostinfo 
Exit Code: 0
Output:
Host Information:

Host time: 2020-06-25T02:14:03.255000000Z
Processor online count: 2
Processor count: 2
Processor online core count: 2
Processor core count: 2
Processor supports HW virtualization: no
Processor supports PAE: yes
Processor supports long mode: yes
Processor supports nested paging: no
Processor#0 speed: unknown
Processor#0 description: Intel(R) Core(TM)2 Duo CPU     E7500  @ 2.93GHz
Processor#1 speed: unknown
Processor#1 description: Intel(R) Core(TM)2 Duo CPU     E7500  @ 2.93GHz
Memory size: 4017 MByte
Memory available: 1728 MByte
Operating system: Windows 10
Operating system version: 10.0.19041

2020-06-24 23:44:03 (7320): 
Command: VBoxManage -q showvminfo "boinc_7ef676997328c214" --machinereadable 
Exit Code: -2135228415
Output:
VBoxManage.exe: error: Could not find a registered machine named 'boinc_7ef676997328c214'
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown
VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2664 of file VBoxManageInfo.cpp

2020-06-24 23:44:04 (7320): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\9/vm_image.vdi" 
Exit Code: -2135228412
Output:
VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\9\vm_image.vdi' (VERR_FILE_NOT_FOUND)
VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp

2020-06-24 23:44:04 (7320): 
Command: VBoxManage -q createvm --name "boinc_7ef676997328c214" --basefolder "C:\ProgramData\BOINC\slots\9" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_7ef676997328c214' is created and registered.
UUID: 6a3f5f72-7bbd-4855-a403-6b5c94ed2a12
Settings file: 'C:\ProgramData\BOINC\slots\9\boinc_7ef676997328c214\boinc_7ef676997328c214.vbox'

2020-06-24 23:44:04 (7320): 
Command: VBoxManage -q modifyvm "boinc_7ef676997328c214" --description "07815535_28_1" 
Exit Code: 0
Output:

2020-06-24 23:44:04 (7320): 
Command: VBoxManage -q modifyvm "boinc_7ef676997328c214" --memory 3072 
Exit Code: 0
Output:

2020-06-24 23:44:05 (7320): 
Command: VBoxManage -q modifyvm "boinc_7ef676997328c214" --cpus 1 
Exit Code: 0
Output:

2020-06-24 23:44:05 (7320): 
Command: VBoxManage -q modifyvm "boinc_7ef676997328c214" --acpi on --ioapic on 
Exit Code: 0
Output:

2020-06-24 23:44:05 (7320): 
Command: VBoxManage -q modifyvm "boinc_7ef676997328c214" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2020-06-24 23:44:06 (7320): 
Command: VBoxManage -q modifyvm "boinc_7ef676997328c214" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2020-06-24 23:44:06 (7320): 
Command: VBoxManage -q modifyvm "boinc_7ef676997328c214" --cableconnected1 on 
Exit Code: 0
Output:

2020-06-24 23:44:06 (7320): 
Command: VBoxManage -q modifyvm "boinc_7ef676997328c214" --usb off 
Exit Code: 0
Output:

2020-06-24 23:44:06 (7320): 
Command: VBoxManage -q modifyvm "boinc_7ef676997328c214" --uart1 off --uart2 off 
Exit Code: 0
Output:

2020-06-24 23:44:07 (7320): 
Command: VBoxManage -q modifyvm "boinc_7ef676997328c214" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2020-06-24 23:44:07 (7320): 
Command: VBoxManage -q modifyvm "boinc_7ef676997328c214" --audio none 
Exit Code: 0
Output:

2020-06-24 23:44:07 (7320): 
Command: VBoxManage -q modifyvm "boinc_7ef676997328c214" --clipboard disabled 
Exit Code: 0
Output:

2020-06-24 23:44:08 (7320): 
Command: VBoxManage -q modifyvm "boinc_7ef676997328c214" --draganddrop disabled 
Exit Code: 0
Output:

2020-06-24 23:44:08 (7320): 
Command: VBoxManage -q storagectl "boinc_7ef676997328c214" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2020-06-24 23:44:08 (7320): 
Command: VBoxManage -q storageattach "boinc_7ef676997328c214" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\ProgramData\BOINC\slots\9/vm_isocontext.iso" 
Exit Code: 0
Output:

2020-06-24 23:44:08 (7320): 
Command: VBoxManage -q storageattach "boinc_7ef676997328c214" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2020-06-24 23:44:09 (7320): 
Command: VBoxManage -q bandwidthctl "boinc_7ef676997328c214" add "boinc_7ef676997328c214_net" --type network --limit 1024G 
Exit Code: 0
Output:

2020-06-24 23:44:09 (7320): 
Command: VBoxManage -q sharedfolder add "boinc_7ef676997328c214" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\9/shared"
Exit Code: 0
Output:

2020-06-24 23:44:09 (7320): 
Command: VBoxManage -q startvm "boinc_7ef676997328c214" --type headless
Exit Code: 1
Output:
Waiting for VM "boinc_7ef676997328c214" to power on...
VBoxManage.exe: error: The virtual machine 'boinc_7ef676997328c214' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\9\boinc_7ef676997328c214\Logs\VBoxHardening.log'
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine

2020-06-24 23:44:10 (7320): 
Command: VBoxManage -q snapshot "boinc_7ef676997328c214" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2020-06-24 23:44:10 (7320): 
Command: VBoxManage -q bandwidthctl "boinc_7ef676997328c214" remove "boinc_7ef676997328c214_net" 
Exit Code: 0
Output:

2020-06-24 23:44:10 (7320): 
Command: VBoxManage -q unregistervm "boinc_7ef676997328c214" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

2020-06-24 23:44:10 (7320): 
Command: VBoxManage -q closemedium dvd "C:\ProgramData\BOINC\slots\9/vm_isocontext.iso" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

23:44:16 (7320): called boinc_finish(1)

</stderr_txt>
]]>