Name | 07825112_14_1 |
Workunit | 6871288 |
Created | 28 Jun 2020, 16:57:09 UTC |
Sent | 28 Jun 2020, 22:16:35 UTC |
Report deadline | 3 Jul 2020, 22:16:35 UTC |
Received | 29 Jun 2020, 3:40:55 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | -1073741819 (0xC0000005) STATUS_ACCESS_VIOLATION |
Computer ID | 1022 |
Run time | 1 min 20 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 4.33 GFLOPS |
Application version | boinc2docker v1.12 (vbox64_mt) windows_x86_64 |
Peak working set size | 7.33 MB |
Peak swap size | 6.21 MB |
Peak disk usage | 499.44 MB |
<core_client_version>7.16.7</core_client_version> <![CDATA[ <message> (unknown error) - exit code -1073741819 (0xc0000005)</message> <stderr_txt> 2020-06-29 07:42:14 (740392): vboxwrapper (7.9.26200): starting 2020-06-29 07:42:18 (740392): Feature: Checkpoint interval offset (472 seconds) 2020-06-29 07:42:18 (740392): Detected: VirtualBox VboxManage Interface (Version: 6.0.14) 2020-06-29 07:42:18 (740392): Detected: Minimum checkpoint interval (600.000000 seconds) 2020-06-29 07:42:22 (740392): Create VM. (boinc_e128041047190140, slot#16) 2020-06-29 07:42:22 (740392): Updating drive controller type and model for desired configuration. 2020-06-29 07:42:27 (740392): Setting Memory Size for VM. (3072MB) 2020-06-29 07:42:28 (740392): Setting CPU Count for VM. (1) 2020-06-29 07:42:30 (740392): Setting Chipset Options for VM. 2020-06-29 07:42:33 (740392): Setting Boot Options for VM. 2020-06-29 07:42:36 (740392): Setting Network Configuration for NAT. 2020-06-29 07:42:38 (740392): Enabling VM Network Access. 2020-06-29 07:42:39 (740392): Disabling USB Support for VM. 2020-06-29 07:42:41 (740392): Disabling COM Port Support for VM. 2020-06-29 07:42:43 (740392): Disabling LPT Port Support for VM. 2020-06-29 07:42:46 (740392): Disabling Audio Support for VM. 2020-06-29 07:42:48 (740392): Disabling Clipboard Support for VM. 2020-06-29 07:42:51 (740392): Disabling Drag and Drop Support for VM. 2020-06-29 07:42:55 (740392): Adding storage controller(s) to VM. 2020-06-29 07:42:56 (740392): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso) 2020-06-29 07:42:58 (740392): Adding VirtualBox Guest Additions to VM. 2020-06-29 07:42:59 (740392): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2020-06-29 07:43:01 (740392): Enabling shared directory for VM. 2020-06-29 07:43:07 (740392): Starting VM using VboxManage interface. (boinc_e128041047190140, slot#16) 2020-06-29 07:43:12 (740392): Error in start VM for VM: -1073741819 Command: VBoxManage -q startvm "boinc_e128041047190140" --type headless Output: Waiting for VM "boinc_e128041047190140" to power on... VBoxManage.exe: error: The virtual machine 'boinc_e128041047190140' has terminated unexpectedly during startup with exit code -1073741819 (0xc0000005). More details may be available in 'C:\BOINC\DATA\slots\16\boinc_e128041047190140\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine 2020-06-29 07:43:12 (740392): VM failed to start. 2020-06-29 07:43:12 (740392): Could not start 2020-06-29 07:43:12 (740392): Powering off VM. 2020-06-29 07:43:12 (740392): Deregistering VM. (boinc_e128041047190140, slot#16) 2020-06-29 07:43:15 (740392): Removing network bandwidth throttle group from VM. 2020-06-29 07:43:16 (740392): Removing VM from VirtualBox. 2020-06-29 07:43:18 (740392): Removing virtual ISO 9660 disk from VirtualBox. Hypervisor System Log: 00:01:44.062577 Saving settings file "C:\Users\nongh\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:01:44.063989 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:01:44.064204 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:01:44.080468 Saving settings file "C:\Users\nongh\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:01:44.094164 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:01:44.111327 Saving settings file "C:\BOINC\DATA\slots\10\boinc_e3b296982ec8f906\boinc_e3b296982ec8f906.vbox" with version "1.16-windows" 00:01:44.137767 Saving settings file "C:\BOINC\DATA\slots\7\boinc_e6cc8380cd67012f\boinc_e6cc8380cd67012f.vbox" with version "1.16-windows" 00:01:45.213194 Saving settings file "C:\BOINC\DATA\slots\7\boinc_e6cc8380cd67012f\boinc_e6cc8380cd67012f.vbox" with version "1.16-windows" 00:01:45.270845 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:01:45.272193 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:01:45.272869 Saving settings file "C:\BOINC\DATA\slots\10\boinc_e3b296982ec8f906\boinc_e3b296982ec8f906.vbox" with version "1.16-windows" 00:01:47.343137 Saving settings file "C:\BOINC\DATA\slots\10\boinc_e3b296982ec8f906\boinc_e3b296982ec8f906.vbox" with version "1.16-windows" 00:01:47.386065 Saving settings file "C:\BOINC\DATA\slots\7\boinc_e6cc8380cd67012f\boinc_e6cc8380cd67012f.vbox" with version "1.16-windows" 00:01:49.594369 Watcher ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={MachineWrap} aText={The virtual machine 'boinc_e128041047190140' has terminated unexpectedly during startup with exit code -1073741819 (0xc0000005). More details may be available in 'C:\BOINC\DATA\slots\16\boinc_e128041047190140\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0 00:01:49.596063 Watcher Reaper: Pid 743280 (b5770) exited normally: -1073741819 (0xc0000005) 00:01:49.763027 Saving settings file "C:\BOINC\DATA\slots\10\boinc_e3b296982ec8f906\boinc_e3b296982ec8f906.vbox" with version "1.16-windows" 00:01:49.793139 Saving settings file "C:\BOINC\DATA\slots\7\boinc_e6cc8380cd67012f\boinc_e6cc8380cd67012f.vbox" with version "1.16-windows" 00:01:52.611535 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:01:52.628025 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:01:52.628264 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:01:52.649894 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:01:52.790000 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={Could not find a registered machine named 'boinc_f967cf41124f5d6b'}, preserve=false aResultDetail=0 00:01:53.151298 Saving settings file "C:\BOINC\DATA\slots\16\boinc_e128041047190140\boinc_e128041047190140.vbox" with version "1.16-windows" 00:01:53.300583 ERROR [COM]: aRC=VBOX_E_FILE_ERROR (0x80bb0004) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Could not find file for the medium 'C:\BOINC\DATA\slots\8\vm_image.vdi' (VERR_FILE_NOT_FOUND)}, preserve=false aResultDetail=-102 00:01:55.406322 Saving settings file "C:\Users\nongh\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:01:55.538778 Saving settings file "C:\BOINC\DATA\slots\8\boinc_f967cf41124f5d6b\boinc_f967cf41124f5d6b.vbox" with version "1.16-windows" 00:01:55.548168 Saving settings file "C:\Users\nongh\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:01:56.556067 Watcher ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={MachineWrap} aText={The virtual machine 'boinc_e3b296982ec8f906' has terminated unexpectedly during startup with exit code -1073741819 (0xc0000005). More details may be available in 'C:\BOINC\DATA\slots\10\boinc_e3b296982ec8f906\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0 00:01:56.557987 Watcher Reaper: Pid 744384 (b5bc0) exited normally: -1073741819 (0xc0000005) 00:01:58.640097 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:01:58.766808 Saving settings file "C:\BOINC\DATA\slots\8\boinc_f967cf41124f5d6b\boinc_f967cf41124f5d6b.vbox" with version "1.16-windows" 00:01:59.810774 Saving settings file "C:\BOINC\DATA\slots\10\boinc_e3b296982ec8f906\boinc_e3b296982ec8f906.vbox" with version "1.16-windows" 00:02:00.006966 Saving settings file "C:\BOINC\DATA\slots\8\boinc_f967cf41124f5d6b\boinc_f967cf41124f5d6b.vbox" with version "1.16-windows" 00:02:01.470583 Saving settings file "C:\Users\nongh\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:02:01.581180 Saving settings file "C:\BOINC\DATA\slots\8\boinc_f967cf41124f5d6b\boinc_f967cf41124f5d6b.vbox" with version "1.16-windows" 00:02:02.353008 Saving settings file "C:\BOINC\DATA\slots\8\boinc_f967cf41124f5d6b\boinc_f967cf41124f5d6b.vbox" with version "1.16-windows" 00:02:03.248508 Saving settings file "C:\BOINC\DATA\slots\8\boinc_f967cf41124f5d6b\boinc_f967cf41124f5d6b.vbox" with version "1.16-windows" 00:02:04.600249 Saving settings file "C:\BOINC\DATA\slots\8\boinc_f967cf41124f5d6b\boinc_f967cf41124f5d6b.vbox" with version "1.16-windows" 00:02:05.174438 Saving settings file "C:\BOINC\DATA\slots\8\boinc_f967cf41124f5d6b\boinc_f967cf41124f5d6b.vbox" with version "1.16-windows" 00:02:05.974110 Saving settings file "C:\BOINC\DATA\slots\8\boinc_f967cf41124f5d6b\boinc_f967cf41124f5d6b.vbox" with version "1.16-windows" 00:02:06.339781 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:02:06.941531 Saving settings file "C:\BOINC\DATA\slots\8\boinc_f967cf41124f5d6b\boinc_f967cf41124f5d6b.vbox" with version "1.16-windows" 00:02:07.091085 Saving settings file "C:\Users\nongh\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:02:08.222211 Saving settings file "C:\BOINC\DATA\slots\8\boinc_f967cf41124f5d6b\boinc_f967cf41124f5d6b.vbox" with version "1.16-windows" VM Execution Log: VM Startup Log: VM Trace Log: VRDE auth library: VBoxAuth Webservice auth. library: VBoxAuth Remote desktop ExtPack: Log history count: 3 Default frontend: Default audio driver: DirectSound Autostart database path: Default Guest Additions ISO: C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso Logging Level: all Proxy Mode: System Proxy URL: 2020-06-29 07:42:18 (740392): Command: VBoxManage -q list hostinfo Exit Code: 0 Output: Host Information: Host time: 2020-06-28T22:42:18.526000000Z Processor online count: 16 Processor count: 16 Processor online core count: 8 Processor core count: 8 Processor supports HW virtualization: no Processor supports PAE: yes Processor supports long mode: yes Processor supports nested paging: no Processor#0 speed: unknown Processor#0 description: AMD Ryzen 7 1800X Eight-Core Processor Processor#1 speed: unknown Processor#1 description: AMD Ryzen 7 1800X Eight-Core Processor Processor#2 speed: unknown Processor#2 description: AMD Ryzen 7 1800X Eight-Core Processor Processor#3 speed: unknown Processor#3 description: AMD Ryzen 7 1800X Eight-Core Processor Processor#4 speed: unknown Processor#4 description: AMD Ryzen 7 1800X Eight-Core Processor Processor#5 speed: unknown Processor#5 description: AMD Ryzen 7 1800X Eight-Core Processor Processor#6 speed: unknown Processor#6 description: AMD Ryzen 7 1800X Eight-Core Processor Processor#7 speed: unknown Processor#7 description: AMD Ryzen 7 1800X Eight-Core Processor Processor#8 speed: unknown Processor#8 description: AMD Ryzen 7 1800X Eight-Core Processor Processor#9 speed: unknown Processor#9 description: AMD Ryzen 7 1800X Eight-Core Processor Processor#10 speed: unknown Processor#10 description: AMD Ryzen 7 1800X Eight-Core Processor Processor#11 speed: unknown Processor#11 description: AMD Ryzen 7 1800X Eight-Core Processor Processor#12 speed: unknown Processor#12 description: AMD Ryzen 7 1800X Eight-Core Processor Processor#13 speed: unknown Processor#13 description: AMD Ryzen 7 1800X Eight-Core Processor Processor#14 speed: unknown Processor#14 description: AMD Ryzen 7 1800X Eight-Core Processor Processor#15 speed: unknown Processor#15 description: AMD Ryzen 7 1800X Eight-Core Processor Memory size: 16331 MByte Memory available: 107 MByte Operating system: Windows 10 Operating system version: 10.0.19041 2020-06-29 07:42:20 (740392): Command: VBoxManage -q showvminfo "boinc_e128041047190140" --machinereadable Exit Code: -2135228415 Output: VBoxManage.exe: error: Could not find a registered machine named 'boinc_e128041047190140' VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2621 of file VBoxManageInfo.cpp 2020-06-29 07:42:22 (740392): Command: VBoxManage -q showhdinfo "C:\BOINC\DATA\slots\16/vm_image.vdi" Exit Code: -2135228412 Output: VBoxManage.exe: error: Could not find file for the medium 'C:\BOINC\DATA\slots\16\vm_image.vdi' (VERR_FILE_NOT_FOUND) VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp 2020-06-29 07:42:25 (740392): Command: VBoxManage -q createvm --name "boinc_e128041047190140" --basefolder "C:\BOINC\DATA\slots\16" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_e128041047190140' is created and registered. UUID: 962ee3b0-d3f8-4214-a830-fc4b72158877 Settings file: 'C:\BOINC\DATA\slots\16\boinc_e128041047190140\boinc_e128041047190140.vbox' 2020-06-29 07:42:27 (740392): Command: VBoxManage -q modifyvm "boinc_e128041047190140" --description "07825112_14_1" Exit Code: 0 Output: 2020-06-29 07:42:28 (740392): Command: VBoxManage -q modifyvm "boinc_e128041047190140" --memory 3072 Exit Code: 0 Output: 2020-06-29 07:42:30 (740392): Command: VBoxManage -q modifyvm "boinc_e128041047190140" --cpus 1 Exit Code: 0 Output: 2020-06-29 07:42:33 (740392): Command: VBoxManage -q modifyvm "boinc_e128041047190140" --acpi on --ioapic on Exit Code: 0 Output: 2020-06-29 07:42:36 (740392): Command: VBoxManage -q modifyvm "boinc_e128041047190140" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2020-06-29 07:42:38 (740392): Command: VBoxManage -q modifyvm "boinc_e128041047190140" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2020-06-29 07:42:39 (740392): Command: VBoxManage -q modifyvm "boinc_e128041047190140" --cableconnected1 on Exit Code: 0 Output: 2020-06-29 07:42:41 (740392): Command: VBoxManage -q modifyvm "boinc_e128041047190140" --usb off Exit Code: 0 Output: 2020-06-29 07:42:43 (740392): Command: VBoxManage -q modifyvm "boinc_e128041047190140" --uart1 off --uart2 off Exit Code: 0 Output: 2020-06-29 07:42:46 (740392): Command: VBoxManage -q modifyvm "boinc_e128041047190140" --lpt1 off --lpt2 off Exit Code: 0 Output: 2020-06-29 07:42:48 (740392): Command: VBoxManage -q modifyvm "boinc_e128041047190140" --audio none Exit Code: 0 Output: 2020-06-29 07:42:51 (740392): Command: VBoxManage -q modifyvm "boinc_e128041047190140" --clipboard disabled Exit Code: 0 Output: 2020-06-29 07:42:55 (740392): Command: VBoxManage -q modifyvm "boinc_e128041047190140" --draganddrop disabled Exit Code: 0 Output: 2020-06-29 07:42:56 (740392): Command: VBoxManage -q storagectl "boinc_e128041047190140" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2020-06-29 07:42:58 (740392): Command: VBoxManage -q storageattach "boinc_e128041047190140" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\BOINC\DATA\slots\16/vm_isocontext.iso" Exit Code: 0 Output: 2020-06-29 07:42:59 (740392): Command: VBoxManage -q storageattach "boinc_e128041047190140" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2020-06-29 07:43:01 (740392): Command: VBoxManage -q bandwidthctl "boinc_e128041047190140" add "boinc_e128041047190140_net" --type network --limit 1024G Exit Code: 0 Output: 2020-06-29 07:43:04 (740392): Command: VBoxManage -q sharedfolder add "boinc_e128041047190140" --name "shared" --hostpath "C:\BOINC\DATA\slots\16/shared" Exit Code: 0 Output: 2020-06-29 07:43:12 (740392): Command: VBoxManage -q startvm "boinc_e128041047190140" --type headless Exit Code: -1073741819 Output: Waiting for VM "boinc_e128041047190140" to power on... VBoxManage.exe: error: The virtual machine 'boinc_e128041047190140' has terminated unexpectedly during startup with exit code -1073741819 (0xc0000005). More details may be available in 'C:\BOINC\DATA\slots\16\boinc_e128041047190140\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine 2020-06-29 07:43:15 (740392): Command: VBoxManage -q snapshot "boinc_e128041047190140" list Exit Code: -108 Output: This machine does not have any snapshots 2020-06-29 07:43:16 (740392): Command: VBoxManage -q bandwidthctl "boinc_e128041047190140" remove "boinc_e128041047190140_net" Exit Code: 0 Output: 2020-06-29 07:43:18 (740392): Command: VBoxManage -q unregistervm "boinc_e128041047190140" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 2020-06-29 07:43:20 (740392): Command: VBoxManage -q closemedium dvd "C:\BOINC\DATA\slots\16/vm_isocontext.iso" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 07:43:31 (740392): called boinc_finish(-1073741819) </stderr_txt> ]]>
©2025 COPYRIGHT 2017-2018 NCN