Task 8539237

Name 07825071_09_1
Workunit 6869369
Created 28 Jun 2020, 19:30:11 UTC
Sent 28 Jun 2020, 22:16:35 UTC
Report deadline 3 Jul 2020, 22:16:35 UTC
Received 29 Jun 2020, 3:40:55 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status -1073741819 (0xC0000005) STATUS_ACCESS_VIOLATION
Computer ID 1022
Run time 1 min 16 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 4.33 GFLOPS
Application version boinc2docker v1.12 (vbox64_mt)
windows_x86_64
Peak working set size 8.71 MB
Peak swap size 6.22 MB
Peak disk usage 603.93 MB

Stderr output

<core_client_version>7.16.7</core_client_version>
<![CDATA[
<message>
(unknown error) - exit code -1073741819 (0xc0000005)</message>
<stderr_txt>
2020-06-29 07:25:49 (733480): vboxwrapper (7.9.26200): starting
2020-06-29 07:26:00 (733480): Feature: Checkpoint interval offset (58 seconds)
2020-06-29 07:26:00 (733480): Detected: VirtualBox VboxManage Interface (Version: 6.0.14)
2020-06-29 07:26:02 (733480): Detected: Minimum checkpoint interval (600.000000 seconds)
2020-06-29 07:26:06 (733480): Create VM. (boinc_1ec8691a4586bccc, slot#7)
2020-06-29 07:26:06 (733480): Updating drive controller type and model for desired configuration.
2020-06-29 07:26:11 (733480): Setting Memory Size for VM. (3072MB)
2020-06-29 07:26:12 (733480): Setting CPU Count for VM. (1)
2020-06-29 07:26:14 (733480): Setting Chipset Options for VM.
2020-06-29 07:26:15 (733480): Setting Boot Options for VM.
2020-06-29 07:26:16 (733480): Setting Network Configuration for NAT.
2020-06-29 07:26:18 (733480): Enabling VM Network Access.
2020-06-29 07:26:19 (733480): Disabling USB Support for VM.
2020-06-29 07:26:20 (733480): Disabling COM Port Support for VM.
2020-06-29 07:26:23 (733480): Disabling LPT Port Support for VM.
2020-06-29 07:26:24 (733480): Disabling Audio Support for VM.
2020-06-29 07:26:25 (733480): Disabling Clipboard Support for VM.
2020-06-29 07:26:28 (733480): Disabling Drag and Drop Support for VM.
2020-06-29 07:26:29 (733480): Adding storage controller(s) to VM.
2020-06-29 07:26:30 (733480): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso)
2020-06-29 07:26:33 (733480): Adding VirtualBox Guest Additions to VM.
2020-06-29 07:26:34 (733480): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2020-06-29 07:26:38 (733480): Enabling shared directory for VM.
2020-06-29 07:26:41 (733480): Starting VM using VboxManage interface. (boinc_1ec8691a4586bccc, slot#7)
2020-06-29 07:26:45 (733480): Error in start VM for VM: -1073741819
Command:
VBoxManage -q startvm "boinc_1ec8691a4586bccc" --type headless
Output:
Waiting for VM "boinc_1ec8691a4586bccc" to power on...
VBoxManage.exe: error: The virtual machine 'boinc_1ec8691a4586bccc' has terminated unexpectedly during startup with exit code -1073741819 (0xc0000005).  More details may be available in 'C:\BOINC\DATA\slots\7\boinc_1ec8691a4586bccc\Logs\VBoxHardening.log'
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine

2020-06-29 07:26:45 (733480): VM failed to start.
2020-06-29 07:26:45 (733480): Could not start 
2020-06-29 07:26:45 (733480): Powering off VM.
2020-06-29 07:26:45 (733480): Deregistering VM. (boinc_1ec8691a4586bccc, slot#7)
2020-06-29 07:26:46 (733480): Removing network bandwidth throttle group from VM.
2020-06-29 07:26:48 (733480): Removing VM from VirtualBox.
2020-06-29 07:26:50 (733480): Removing virtual ISO 9660 disk from VirtualBox.

    Hypervisor System Log:

00:00:01.766240          Loading settings file "C:\Users\nongh\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:06.800337          netIfIsWireless: CreateFile on '\\.\{8DB4E834-43A6-4544-9963-1AF737235710}' failed with rcWin=2 (0x2) - ignoring
00:00:06.873998          HostDnsMonitor::updateInfo
00:00:06.874836          HostDnsMonitor: old information
00:00:06.874844            no server entries
00:00:06.874845            no domain set
00:00:06.874846            no search string entries
00:00:06.874847          HostDnsMonitor: new information
00:00:06.874847            server 1: 203.248.252.2
00:00:06.874848            server 2: 164.124.101.2
00:00:06.874849            no domain set
00:00:06.874850            no search string entries
00:00:07.317044          SUPR0QueryVTCaps -> VERR_SVM_DISABLED
00:00:07.322145          VD: VDInit finished with VINF_SUCCESS
00:00:07.327161          VirtualBox: object created
00:00:13.095910          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={Could not find a registered machine named 'boinc_1ec8691a4586bccc'}, preserve=false aResultDetail=0
00:00:14.353270          ERROR [COM]: aRC=VBOX_E_FILE_ERROR (0x80bb0004) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Could not find file for the medium 'C:\BOINC\DATA\slots\7\vm_image.vdi' (VERR_FILE_NOT_FOUND)}, preserve=false aResultDetail=-102
00:00:17.296808          Saving settings file "C:\BOINC\DATA\slots\7\boinc_1ec8691a4586bccc\boinc_1ec8691a4586bccc.vbox" with version "1.16-windows"
00:00:17.311266          Saving settings file "C:\Users\nongh\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:18.326346          Saving settings file "C:\BOINC\DATA\slots\7\boinc_1ec8691a4586bccc\boinc_1ec8691a4586bccc.vbox" with version "1.16-windows"
00:00:20.276613          Saving settings file "C:\BOINC\DATA\slots\7\boinc_1ec8691a4586bccc\boinc_1ec8691a4586bccc.vbox" with version "1.16-windows"
00:00:22.225080          Saving settings file "C:\BOINC\DATA\slots\7\boinc_1ec8691a4586bccc\boinc_1ec8691a4586bccc.vbox" with version "1.16-windows"
00:00:23.318667          Saving settings file "C:\BOINC\DATA\slots\7\boinc_1ec8691a4586bccc\boinc_1ec8691a4586bccc.vbox" with version "1.16-windows"
00:00:24.313566          Saving settings file "C:\BOINC\DATA\slots\7\boinc_1ec8691a4586bccc\boinc_1ec8691a4586bccc.vbox" with version "1.16-windows"
00:00:25.544024          Saving settings file "C:\BOINC\DATA\slots\7\boinc_1ec8691a4586bccc\boinc_1ec8691a4586bccc.vbox" with version "1.16-windows"
00:00:27.137800          Saving settings file "C:\BOINC\DATA\slots\7\boinc_1ec8691a4586bccc\boinc_1ec8691a4586bccc.vbox" with version "1.16-windows"
00:00:27.870925          Saving settings file "C:\BOINC\DATA\slots\7\boinc_1ec8691a4586bccc\boinc_1ec8691a4586bccc.vbox" with version "1.16-windows"
00:00:31.197156          Saving settings file "C:\BOINC\DATA\slots\7\boinc_1ec8691a4586bccc\boinc_1ec8691a4586bccc.vbox" with version "1.16-windows"
00:00:32.174561          Saving settings file "C:\BOINC\DATA\slots\7\boinc_1ec8691a4586bccc\boinc_1ec8691a4586bccc.vbox" with version "1.16-windows"
00:00:32.894225          Saving settings file "C:\BOINC\DATA\slots\7\boinc_1ec8691a4586bccc\boinc_1ec8691a4586bccc.vbox" with version "1.16-windows"
00:00:35.855176          Saving settings file "C:\BOINC\DATA\slots\7\boinc_1ec8691a4586bccc\boinc_1ec8691a4586bccc.vbox" with version "1.16-windows"
00:00:36.845909          Saving settings file "C:\BOINC\DATA\slots\7\boinc_1ec8691a4586bccc\boinc_1ec8691a4586bccc.vbox" with version "1.16-windows"
00:00:37.787867          Saving settings file "C:\BOINC\DATA\slots\7\boinc_1ec8691a4586bccc\boinc_1ec8691a4586bccc.vbox" with version "1.16-windows"
00:00:40.423960          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:40.552925          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:40.554458          Saving settings file "C:\Users\nongh\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:40.568693          Saving settings file "C:\Users\nongh\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:40.579799          Saving settings file "C:\BOINC\DATA\slots\7\boinc_1ec8691a4586bccc\boinc_1ec8691a4586bccc.vbox" with version "1.16-windows"
00:00:41.615052          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:41.623008          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:41.623232          Saving settings file "C:\Users\nongh\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:41.632726          Saving settings file "C:\Users\nongh\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:41.643399          Saving settings file "C:\BOINC\DATA\slots\7\boinc_1ec8691a4586bccc\boinc_1ec8691a4586bccc.vbox" with version "1.16-windows"
00:00:45.940062          Saving settings file "C:\BOINC\DATA\slots\7\boinc_1ec8691a4586bccc\boinc_1ec8691a4586bccc.vbox" with version "1.16-windows"
00:00:46.723580          Saving settings file "C:\BOINC\DATA\slots\7\boinc_1ec8691a4586bccc\boinc_1ec8691a4586bccc.vbox" with version "1.16-windows"
00:00:49.249416          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:49.250017          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:49.307794          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:53.453949 Watcher  ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={MachineWrap} aText={The virtual machine 'boinc_1ec8691a4586bccc' has terminated unexpectedly during startup with exit code -1073741819 (0xc0000005).  More details may be available in 'C:\BOINC\DATA\slots\7\boinc_1ec8691a4586bccc\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0
00:00:53.459524 Watcher  Reaper: Pid 737176 (b3f98) exited normally: -1073741819 (0xc0000005)
00:00:54.576206          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:55.759053          Saving settings file "C:\BOINC\DATA\slots\7\boinc_1ec8691a4586bccc\boinc_1ec8691a4586bccc.vbox" with version "1.16-windows"
00:00:58.382464          Saving settings file "C:\Users\nongh\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:01:05.765171 main     VirtualBox: object deletion starts
00:01:05.788769 Watcher  ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0
00:01:05.789611 main     VirtualBox: object deleted

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

     VDI
VRDE auth library:               VBoxAuth
Webservice auth. library:        VBoxAuth
Remote desktop ExtPack:          
Log history count:               3
Default frontend:                
Default audio driver:            DirectSound
Autostart database path:         
Default Guest Additions ISO:     C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso
Logging Level:                   all
Proxy Mode:                      System
Proxy URL:                       

2020-06-29 07:26:02 (733480): 
Command: VBoxManage -q list hostinfo 
Exit Code: 0
Output:
Host Information:

Host time: 2020-06-28T22:26:02.839000000Z
Processor online count: 16
Processor count: 16
Processor online core count: 8
Processor core count: 8
Processor supports HW virtualization: no
Processor supports PAE: yes
Processor supports long mode: yes
Processor supports nested paging: no
Processor#0 speed: unknown
Processor#0 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#1 speed: unknown
Processor#1 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#2 speed: unknown
Processor#2 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#3 speed: unknown
Processor#3 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#4 speed: unknown
Processor#4 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#5 speed: unknown
Processor#5 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#6 speed: unknown
Processor#6 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#7 speed: unknown
Processor#7 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#8 speed: unknown
Processor#8 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#9 speed: unknown
Processor#9 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#10 speed: unknown
Processor#10 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#11 speed: unknown
Processor#11 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#12 speed: unknown
Processor#12 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#13 speed: unknown
Processor#13 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#14 speed: unknown
Processor#14 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#15 speed: unknown
Processor#15 description: AMD Ryzen 7 1800X Eight-Core Processor
Memory size: 16331 MByte
Memory available: 74 MByte
Operating system: Windows 10
Operating system version: 10.0.19041

2020-06-29 07:26:05 (733480): 
Command: VBoxManage -q showvminfo "boinc_1ec8691a4586bccc" --machinereadable 
Exit Code: -2135228415
Output:
VBoxManage.exe: error: Could not find a registered machine named 'boinc_1ec8691a4586bccc'
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown
VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2621 of file VBoxManageInfo.cpp

2020-06-29 07:26:06 (733480): 
Command: VBoxManage -q showhdinfo "C:\BOINC\DATA\slots\7/vm_image.vdi" 
Exit Code: -2135228412
Output:
VBoxManage.exe: error: Could not find file for the medium 'C:\BOINC\DATA\slots\7\vm_image.vdi' (VERR_FILE_NOT_FOUND)
VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp

2020-06-29 07:26:09 (733480): 
Command: VBoxManage -q createvm --name "boinc_1ec8691a4586bccc" --basefolder "C:\BOINC\DATA\slots\7" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_1ec8691a4586bccc' is created and registered.
UUID: 35067ea7-319a-4c4c-b167-b738b7dd66af
Settings file: 'C:\BOINC\DATA\slots\7\boinc_1ec8691a4586bccc\boinc_1ec8691a4586bccc.vbox'

2020-06-29 07:26:11 (733480): 
Command: VBoxManage -q modifyvm "boinc_1ec8691a4586bccc" --description "07825071_09_1" 
Exit Code: 0
Output:

2020-06-29 07:26:12 (733480): 
Command: VBoxManage -q modifyvm "boinc_1ec8691a4586bccc" --memory 3072 
Exit Code: 0
Output:

2020-06-29 07:26:14 (733480): 
Command: VBoxManage -q modifyvm "boinc_1ec8691a4586bccc" --cpus 1 
Exit Code: 0
Output:

2020-06-29 07:26:15 (733480): 
Command: VBoxManage -q modifyvm "boinc_1ec8691a4586bccc" --acpi on --ioapic on 
Exit Code: 0
Output:

2020-06-29 07:26:16 (733480): 
Command: VBoxManage -q modifyvm "boinc_1ec8691a4586bccc" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2020-06-29 07:26:18 (733480): 
Command: VBoxManage -q modifyvm "boinc_1ec8691a4586bccc" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2020-06-29 07:26:19 (733480): 
Command: VBoxManage -q modifyvm "boinc_1ec8691a4586bccc" --cableconnected1 on 
Exit Code: 0
Output:

2020-06-29 07:26:20 (733480): 
Command: VBoxManage -q modifyvm "boinc_1ec8691a4586bccc" --usb off 
Exit Code: 0
Output:

2020-06-29 07:26:23 (733480): 
Command: VBoxManage -q modifyvm "boinc_1ec8691a4586bccc" --uart1 off --uart2 off 
Exit Code: 0
Output:

2020-06-29 07:26:24 (733480): 
Command: VBoxManage -q modifyvm "boinc_1ec8691a4586bccc" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2020-06-29 07:26:25 (733480): 
Command: VBoxManage -q modifyvm "boinc_1ec8691a4586bccc" --audio none 
Exit Code: 0
Output:

2020-06-29 07:26:28 (733480): 
Command: VBoxManage -q modifyvm "boinc_1ec8691a4586bccc" --clipboard disabled 
Exit Code: 0
Output:

2020-06-29 07:26:29 (733480): 
Command: VBoxManage -q modifyvm "boinc_1ec8691a4586bccc" --draganddrop disabled 
Exit Code: 0
Output:

2020-06-29 07:26:30 (733480): 
Command: VBoxManage -q storagectl "boinc_1ec8691a4586bccc" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2020-06-29 07:26:33 (733480): 
Command: VBoxManage -q storageattach "boinc_1ec8691a4586bccc" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\BOINC\DATA\slots\7/vm_isocontext.iso" 
Exit Code: 0
Output:

2020-06-29 07:26:34 (733480): 
Command: VBoxManage -q storageattach "boinc_1ec8691a4586bccc" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2020-06-29 07:26:38 (733480): 
Command: VBoxManage -q bandwidthctl "boinc_1ec8691a4586bccc" add "boinc_1ec8691a4586bccc_net" --type network --limit 1024G 
Exit Code: 0
Output:

2020-06-29 07:26:39 (733480): 
Command: VBoxManage -q sharedfolder add "boinc_1ec8691a4586bccc" --name "shared" --hostpath "C:\BOINC\DATA\slots\7/shared"
Exit Code: 0
Output:

2020-06-29 07:26:45 (733480): 
Command: VBoxManage -q startvm "boinc_1ec8691a4586bccc" --type headless
Exit Code: -1073741819
Output:
Waiting for VM "boinc_1ec8691a4586bccc" to power on...
VBoxManage.exe: error: The virtual machine 'boinc_1ec8691a4586bccc' has terminated unexpectedly during startup with exit code -1073741819 (0xc0000005).  More details may be available in 'C:\BOINC\DATA\slots\7\boinc_1ec8691a4586bccc\Logs\VBoxHardening.log'
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine

2020-06-29 07:26:46 (733480): 
Command: VBoxManage -q snapshot "boinc_1ec8691a4586bccc" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2020-06-29 07:26:48 (733480): 
Command: VBoxManage -q bandwidthctl "boinc_1ec8691a4586bccc" remove "boinc_1ec8691a4586bccc_net" 
Exit Code: 0
Output:

2020-06-29 07:26:50 (733480): 
Command: VBoxManage -q unregistervm "boinc_1ec8691a4586bccc" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

2020-06-29 07:26:53 (733480): 
Command: VBoxManage -q closemedium dvd "C:\BOINC\DATA\slots\7/vm_isocontext.iso" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

07:27:01 (733480): called boinc_finish(-1073741819)

</stderr_txt>
]]>


©2025 COPYRIGHT 2017-2018 NCN