Task 8540113

Name 07824893_07_1
Workunit 6867139
Created 28 Jun 2020, 20:56:12 UTC
Sent 28 Jun 2020, 22:16:35 UTC
Report deadline 3 Jul 2020, 22:16:35 UTC
Received 29 Jun 2020, 3:40:55 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status -1073741819 (0xC0000005) STATUS_ACCESS_VIOLATION
Computer ID 1022
Run time 2 min 45 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 4.33 GFLOPS
Application version boinc2docker v1.12 (vbox64_mt)
windows_x86_64
Peak working set size 10.14 MB
Peak swap size 6.21 MB
Peak disk usage 273.79 MB

Stderr output

<core_client_version>7.16.7</core_client_version>
<![CDATA[
<message>
(unknown error) - exit code -1073741819 (0xc0000005)</message>
<stderr_txt>
2020-06-29 07:39:30 (738972): vboxwrapper (7.9.26200): starting
2020-06-29 07:39:37 (738972): Feature: Checkpoint interval offset (387 seconds)
2020-06-29 07:39:37 (738972): Detected: VirtualBox VboxManage Interface (Version: 6.0.14)
2020-06-29 07:39:42 (738972): Detected: Minimum checkpoint interval (600.000000 seconds)
2020-06-29 07:39:47 (738972): Create VM. (boinc_cad3a3912aa425ae, slot#10)
2020-06-29 07:39:47 (738972): Updating drive controller type and model for desired configuration.
2020-06-29 07:39:51 (738972): Setting Memory Size for VM. (3072MB)
2020-06-29 07:39:56 (738972): Setting CPU Count for VM. (1)
2020-06-29 07:40:00 (738972): Setting Chipset Options for VM.
2020-06-29 07:40:06 (738972): Setting Boot Options for VM.
2020-06-29 07:40:23 (738972): Setting Network Configuration for NAT.
2020-06-29 07:40:29 (738972): Enabling VM Network Access.
2020-06-29 07:40:49 (738972): Disabling USB Support for VM.
2020-06-29 07:41:04 (738972): Disabling COM Port Support for VM.
2020-06-29 07:41:16 (738972): Disabling LPT Port Support for VM.
2020-06-29 07:41:28 (738972): Disabling Audio Support for VM.
2020-06-29 07:41:29 (738972): Disabling Clipboard Support for VM.
2020-06-29 07:41:30 (738972): Disabling Drag and Drop Support for VM.
2020-06-29 07:41:33 (738972): Adding storage controller(s) to VM.
2020-06-29 07:41:34 (738972): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso)
2020-06-29 07:41:36 (738972): Adding VirtualBox Guest Additions to VM.
2020-06-29 07:41:37 (738972): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2020-06-29 07:41:38 (738972): Enabling shared directory for VM.
2020-06-29 07:41:42 (738972): Starting VM using VboxManage interface. (boinc_cad3a3912aa425ae, slot#10)
2020-06-29 07:41:48 (738972): Error in start VM for VM: -1073741819
Command:
VBoxManage -q startvm "boinc_cad3a3912aa425ae" --type headless
Output:
Waiting for VM "boinc_cad3a3912aa425ae" to power on...
VBoxManage.exe: error: The virtual machine 'boinc_cad3a3912aa425ae' has terminated unexpectedly during startup with exit code -1073741819 (0xc0000005).  More details may be available in 'C:\BOINC\DATA\slots\10\boinc_cad3a3912aa425ae\Logs\VBoxHardening.log'
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine

2020-06-29 07:41:48 (738972): VM failed to start.
2020-06-29 07:41:48 (738972): Could not start 
2020-06-29 07:41:48 (738972): Powering off VM.
2020-06-29 07:41:48 (738972): Deregistering VM. (boinc_cad3a3912aa425ae, slot#10)
2020-06-29 07:41:50 (738972): Removing network bandwidth throttle group from VM.
2020-06-29 07:41:52 (738972): Removing VM from VirtualBox.
2020-06-29 07:41:54 (738972): Removing virtual ISO 9660 disk from VirtualBox.

    Hypervisor System Log:

00:00:14.303298          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:14.326875          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:14.327050          Saving settings file "C:\Users\nongh\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:14.353182          Saving settings file "C:\Users\nongh\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:14.364112          Saving settings file "C:\BOINC\DATA\slots\10\boinc_cad3a3912aa425ae\boinc_cad3a3912aa425ae.vbox" with version "1.16-windows"
00:00:15.034396          Saving settings file "C:\BOINC\DATA\slots\7\boinc_d5622a98a4a03995\boinc_d5622a98a4a03995.vbox" with version "1.16-windows"
00:00:15.298657          Saving settings file "C:\BOINC\DATA\slots\10\boinc_cad3a3912aa425ae\boinc_cad3a3912aa425ae.vbox" with version "1.16-windows"
00:00:18.229829          Saving settings file "C:\BOINC\DATA\slots\10\boinc_cad3a3912aa425ae\boinc_cad3a3912aa425ae.vbox" with version "1.16-windows"
00:00:18.248983          Saving settings file "C:\BOINC\DATA\slots\7\boinc_d5622a98a4a03995\boinc_d5622a98a4a03995.vbox" with version "1.16-windows"
00:00:18.567508 Watcher  ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={MachineWrap} aText={The virtual machine 'boinc_bd24ec667ff9bf3b' has terminated unexpectedly during startup with exit code -1073741819 (0xc0000005).  More details may be available in 'C:\BOINC\DATA\slots\16\boinc_bd24ec667ff9bf3b\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0
00:00:18.568940 Watcher  Reaper: Pid 740160 (b4b40) exited normally: -1073741819 (0xc0000005)
00:00:19.971161          Saving settings file "C:\BOINC\DATA\slots\7\boinc_d5622a98a4a03995\boinc_d5622a98a4a03995.vbox" with version "1.16-windows"
00:00:19.976195          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:19.976403          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:19.996662          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:20.372424          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:21.632527          Saving settings file "C:\BOINC\DATA\slots\7\boinc_d5622a98a4a03995\boinc_d5622a98a4a03995.vbox" with version "1.16-windows"
00:00:22.560872          Saving settings file "C:\BOINC\DATA\slots\16\boinc_bd24ec667ff9bf3b\boinc_bd24ec667ff9bf3b.vbox" with version "1.16-windows"
00:00:23.432342          Saving settings file "C:\BOINC\DATA\slots\7\boinc_d5622a98a4a03995\boinc_d5622a98a4a03995.vbox" with version "1.16-windows"
00:00:23.727600          Saving settings file "C:\Users\nongh\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:24.303719          Saving settings file "C:\BOINC\DATA\slots\7\boinc_d5622a98a4a03995\boinc_d5622a98a4a03995.vbox" with version "1.16-windows"
00:00:25.730442 Watcher  ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={MachineWrap} aText={The virtual machine 'boinc_cad3a3912aa425ae' has terminated unexpectedly during startup with exit code -1073741819 (0xc0000005).  More details may be available in 'C:\BOINC\DATA\slots\10\boinc_cad3a3912aa425ae\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0
00:00:25.733944 Watcher  Reaper: Pid 743196 (b571c) exited normally: -1073741819 (0xc0000005)
00:00:25.933307          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={Could not find a registered machine named 'boinc_dc878bb65250cea4'}, preserve=false aResultDetail=0
00:00:25.937706          Saving settings file "C:\BOINC\DATA\slots\7\boinc_d5622a98a4a03995\boinc_d5622a98a4a03995.vbox" with version "1.16-windows"
00:00:27.734520          ERROR [COM]: aRC=VBOX_E_FILE_ERROR (0x80bb0004) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Could not find file for the medium 'C:\BOINC\DATA\slots\8\vm_image.vdi' (VERR_FILE_NOT_FOUND)}, preserve=false aResultDetail=-102
00:00:27.755889          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:29.164232          Saving settings file "C:\BOINC\DATA\slots\10\boinc_cad3a3912aa425ae\boinc_cad3a3912aa425ae.vbox" with version "1.16-windows"
00:00:29.540862          Saving settings file "C:\BOINC\DATA\slots\8\boinc_dc878bb65250cea4\boinc_dc878bb65250cea4.vbox" with version "1.16-windows"
00:00:29.551744          Saving settings file "C:\Users\nongh\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:31.973977          Saving settings file "C:\Users\nongh\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:32.147053          Saving settings file "C:\BOINC\DATA\slots\8\boinc_dc878bb65250cea4\boinc_dc878bb65250cea4.vbox" with version "1.16-windows"
00:00:34.876931          Saving settings file "C:\BOINC\DATA\slots\8\boinc_dc878bb65250cea4\boinc_dc878bb65250cea4.vbox" with version "1.16-windows"
00:00:38.458059          Saving settings file "C:\BOINC\DATA\slots\8\boinc_dc878bb65250cea4\boinc_dc878bb65250cea4.vbox" with version "1.16-windows"
00:00:39.754749          Saving settings file "C:\BOINC\DATA\slots\8\boinc_dc878bb65250cea4\boinc_dc878bb65250cea4.vbox" with version "1.16-windows"
00:00:39.899328          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={Could not find a registered machine named 'boinc_ddb16e85b431f6da'}, preserve=false aResultDetail=0
00:00:41.653740          Saving settings file "C:\BOINC\DATA\slots\8\boinc_dc878bb65250cea4\boinc_dc878bb65250cea4.vbox" with version "1.16-windows"
00:00:41.764289          ERROR [COM]: aRC=VBOX_E_FILE_ERROR (0x80bb0004) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Could not find file for the medium 'C:\BOINC\DATA\slots\20\vm_image.vdi' (VERR_FILE_NOT_FOUND)}, preserve=false aResultDetail=-102
00:00:42.918908          Saving settings file "C:\BOINC\DATA\slots\20\boinc_ddb16e85b431f6da\boinc_ddb16e85b431f6da.vbox" with version "1.16-windows"
00:00:42.927892          Saving settings file "C:\BOINC\DATA\slots\8\boinc_dc878bb65250cea4\boinc_dc878bb65250cea4.vbox" with version "1.16-windows"
00:00:42.963109          Saving settings file "C:\Users\nongh\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:43.954802          Saving settings file "C:\BOINC\DATA\slots\20\boinc_ddb16e85b431f6da\boinc_ddb16e85b431f6da.vbox" with version "1.16-windows"
00:00:43.956634          Saving settings file "C:\BOINC\DATA\slots\8\boinc_dc878bb65250cea4\boinc_dc878bb65250cea4.vbox" with version "1.16-windows"
00:00:44.628267          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:


VRDE auth library:               VBoxAuth
Webservice auth. library:        VBoxAuth
Remote desktop ExtPack:          
Log history count:               3
Default frontend:                
Default audio driver:            DirectSound
Autostart database path:         
Default Guest Additions ISO:     C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso
Logging Level:                   all
Proxy Mode:                      System
Proxy URL:                       

2020-06-29 07:39:42 (738972): 
Command: VBoxManage -q list hostinfo 
Exit Code: 0
Output:
Host Information:

Host time: 2020-06-28T22:39:42.046000000Z
Processor online count: 16
Processor count: 16
Processor online core count: 8
Processor core count: 8
Processor supports HW virtualization: no
Processor supports PAE: yes
Processor supports long mode: yes
Processor supports nested paging: no
Processor#0 speed: unknown
Processor#0 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#1 speed: unknown
Processor#1 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#2 speed: unknown
Processor#2 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#3 speed: unknown
Processor#3 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#4 speed: unknown
Processor#4 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#5 speed: unknown
Processor#5 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#6 speed: unknown
Processor#6 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#7 speed: unknown
Processor#7 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#8 speed: unknown
Processor#8 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#9 speed: unknown
Processor#9 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#10 speed: unknown
Processor#10 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#11 speed: unknown
Processor#11 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#12 speed: unknown
Processor#12 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#13 speed: unknown
Processor#13 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#14 speed: unknown
Processor#14 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#15 speed: unknown
Processor#15 description: AMD Ryzen 7 1800X Eight-Core Processor
Memory size: 16331 MByte
Memory available: 152 MByte
Operating system: Windows 10
Operating system version: 10.0.19041

2020-06-29 07:39:44 (738972): 
Command: VBoxManage -q showvminfo "boinc_cad3a3912aa425ae" --machinereadable 
Exit Code: -2135228415
Output:
VBoxManage.exe: error: Could not find a registered machine named 'boinc_cad3a3912aa425ae'
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown
VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2621 of file VBoxManageInfo.cpp

2020-06-29 07:39:47 (738972): 
Command: VBoxManage -q showhdinfo "C:\BOINC\DATA\slots\10/vm_image.vdi" 
Exit Code: -2135228412
Output:
VBoxManage.exe: error: Could not find file for the medium 'C:\BOINC\DATA\slots\10\vm_image.vdi' (VERR_FILE_NOT_FOUND)
VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp

2020-06-29 07:39:48 (738972): 
Command: VBoxManage -q createvm --name "boinc_cad3a3912aa425ae" --basefolder "C:\BOINC\DATA\slots\10" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_cad3a3912aa425ae' is created and registered.
UUID: a2e088a0-1aee-4fb6-b03b-fe14e864f560
Settings file: 'C:\BOINC\DATA\slots\10\boinc_cad3a3912aa425ae\boinc_cad3a3912aa425ae.vbox'

2020-06-29 07:39:51 (738972): 
Command: VBoxManage -q modifyvm "boinc_cad3a3912aa425ae" --description "07824893_07_1" 
Exit Code: 0
Output:

2020-06-29 07:39:56 (738972): 
Command: VBoxManage -q modifyvm "boinc_cad3a3912aa425ae" --memory 3072 
Exit Code: 0
Output:

2020-06-29 07:40:00 (738972): 
Command: VBoxManage -q modifyvm "boinc_cad3a3912aa425ae" --cpus 1 
Exit Code: 0
Output:

2020-06-29 07:40:06 (738972): 
Command: VBoxManage -q modifyvm "boinc_cad3a3912aa425ae" --acpi on --ioapic on 
Exit Code: 0
Output:

2020-06-29 07:40:23 (738972): 
Command: VBoxManage -q modifyvm "boinc_cad3a3912aa425ae" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2020-06-29 07:40:29 (738972): 
Command: VBoxManage -q modifyvm "boinc_cad3a3912aa425ae" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2020-06-29 07:40:49 (738972): 
Command: VBoxManage -q modifyvm "boinc_cad3a3912aa425ae" --cableconnected1 on 
Exit Code: 0
Output:

2020-06-29 07:41:04 (738972): 
Command: VBoxManage -q modifyvm "boinc_cad3a3912aa425ae" --usb off 
Exit Code: 0
Output:

2020-06-29 07:41:16 (738972): 
Command: VBoxManage -q modifyvm "boinc_cad3a3912aa425ae" --uart1 off --uart2 off 
Exit Code: 0
Output:

2020-06-29 07:41:28 (738972): 
Command: VBoxManage -q modifyvm "boinc_cad3a3912aa425ae" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2020-06-29 07:41:29 (738972): 
Command: VBoxManage -q modifyvm "boinc_cad3a3912aa425ae" --audio none 
Exit Code: 0
Output:

2020-06-29 07:41:30 (738972): 
Command: VBoxManage -q modifyvm "boinc_cad3a3912aa425ae" --clipboard disabled 
Exit Code: 0
Output:

2020-06-29 07:41:33 (738972): 
Command: VBoxManage -q modifyvm "boinc_cad3a3912aa425ae" --draganddrop disabled 
Exit Code: 0
Output:

2020-06-29 07:41:33 (738972): 
Command: VBoxManage -q storagectl "boinc_cad3a3912aa425ae" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2020-06-29 07:41:36 (738972): 
Command: VBoxManage -q storageattach "boinc_cad3a3912aa425ae" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\BOINC\DATA\slots\10/vm_isocontext.iso" 
Exit Code: 0
Output:

2020-06-29 07:41:37 (738972): 
Command: VBoxManage -q storageattach "boinc_cad3a3912aa425ae" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2020-06-29 07:41:38 (738972): 
Command: VBoxManage -q bandwidthctl "boinc_cad3a3912aa425ae" add "boinc_cad3a3912aa425ae_net" --type network --limit 1024G 
Exit Code: 0
Output:

2020-06-29 07:41:41 (738972): 
Command: VBoxManage -q sharedfolder add "boinc_cad3a3912aa425ae" --name "shared" --hostpath "C:\BOINC\DATA\slots\10/shared"
Exit Code: 0
Output:

2020-06-29 07:41:48 (738972): 
Command: VBoxManage -q startvm "boinc_cad3a3912aa425ae" --type headless
Exit Code: -1073741819
Output:
Waiting for VM "boinc_cad3a3912aa425ae" to power on...
VBoxManage.exe: error: The virtual machine 'boinc_cad3a3912aa425ae' has terminated unexpectedly during startup with exit code -1073741819 (0xc0000005).  More details may be available in 'C:\BOINC\DATA\slots\10\boinc_cad3a3912aa425ae\Logs\VBoxHardening.log'
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine

2020-06-29 07:41:50 (738972): 
Command: VBoxManage -q snapshot "boinc_cad3a3912aa425ae" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2020-06-29 07:41:52 (738972): 
Command: VBoxManage -q bandwidthctl "boinc_cad3a3912aa425ae" remove "boinc_cad3a3912aa425ae_net" 
Exit Code: 0
Output:

2020-06-29 07:41:54 (738972): 
Command: VBoxManage -q unregistervm "boinc_cad3a3912aa425ae" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

2020-06-29 07:41:57 (738972): 
Command: VBoxManage -q closemedium dvd "C:\BOINC\DATA\slots\10/vm_isocontext.iso" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

07:42:08 (738972): called boinc_finish(-1073741819)

</stderr_txt>
]]>


©2025 COPYRIGHT 2017-2018 NCN