Task 8768196

Name 07843405_31_1
Workunit 7034100
Created 10 Jul 2020, 21:30:26 UTC
Sent 10 Jul 2020, 21:37:55 UTC
Report deadline 15 Jul 2020, 21:37:55 UTC
Received 14 Jul 2020, 18:07:51 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status -2147467259 (0x80004005) Unknown error code
Computer ID 7947
Run time
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 5.59 GFLOPS
Application version boinc2docker v1.12 (vbox64_mt)
windows_x86_64

Stderr output

<core_client_version>7.16.7</core_client_version>
<![CDATA[
<message>
M��ritt�m�t�n virhe.
 (0x80004005) - exit code -2147467259 (0x80004005)</message>
<stderr_txt>
2020-07-11 00:38:01 (8700): vboxwrapper (7.9.26200): starting
2020-07-11 00:38:01 (8700): Feature: Checkpoint interval offset (520 seconds)
2020-07-11 00:38:01 (8700): Detected: VirtualBox VboxManage Interface (Version: 6.1.10)
2020-07-11 00:38:02 (8700): Detected: Minimum checkpoint interval (600.000000 seconds)
2020-07-11 00:38:02 (8700): Create VM. (boinc_180e1713f56c994a, slot#7)
2020-07-11 00:38:02 (8700): Updating drive controller type and model for desired configuration.
2020-07-11 00:38:03 (8700): Setting Memory Size for VM. (3072MB)
2020-07-11 00:38:03 (8700): Setting CPU Count for VM. (1)
2020-07-11 00:38:03 (8700): Setting Chipset Options for VM.
2020-07-11 00:38:04 (8700): Setting Boot Options for VM.
2020-07-11 00:38:04 (8700): Setting Network Configuration for NAT.
2020-07-11 00:38:04 (8700): Enabling VM Network Access.
2020-07-11 00:38:04 (8700): Disabling USB Support for VM.
2020-07-11 00:38:05 (8700): Disabling COM Port Support for VM.
2020-07-11 00:38:05 (8700): Disabling LPT Port Support for VM.
2020-07-11 00:38:05 (8700): Disabling Audio Support for VM.
2020-07-11 00:38:05 (8700): Disabling Clipboard Support for VM.
2020-07-11 00:38:06 (8700): Disabling Drag and Drop Support for VM.
2020-07-11 00:38:06 (8700): Adding storage controller(s) to VM.
2020-07-11 00:38:06 (8700): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso)
2020-07-11 00:38:07 (8700): Adding VirtualBox Guest Additions to VM.
2020-07-11 00:38:07 (8700): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2020-07-11 00:38:07 (8700): Enabling shared directory for VM.
2020-07-11 00:38:08 (8700): Starting VM using VboxManage interface. (boinc_180e1713f56c994a, slot#7)
2020-07-11 00:38:10 (8700): Error in start VM for VM: -2147467259
Command:
VBoxManage -q startvm "boinc_180e1713f56c994a" --type headless
Output:
Waiting for VM "boinc_180e1713f56c994a" to power on...
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: AMD-V is disabled in the BIOS (or by the host OS) (VERR_SVM_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole

2020-07-11 00:38:10 (8700): VM failed to start.
2020-07-11 00:38:10 (8700): Could not start 
2020-07-11 00:38:10 (8700): Powering off VM.
2020-07-11 00:38:10 (8700): Deregistering VM. (boinc_180e1713f56c994a, slot#7)
2020-07-11 00:38:10 (8700): Removing network bandwidth throttle group from VM.
2020-07-11 00:38:10 (8700): Removing VM from VirtualBox.
2020-07-11 00:38:11 (8700): Removing virtual ISO 9660 disk from VirtualBox.

    Hypervisor System Log:

00:00:05.373631          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_1fe1fd4c93af8859\boinc_1fe1fd4c93af8859.vbox" with version "1.16-windows"
00:00:05.539089          Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_180e1713f56c994a\boinc_180e1713f56c994a.vbox" with version "1.16-windows"
00:00:05.642399          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:05.646164          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:05.646553          Saving settings file "C:\Users\esara\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:05.663062          Saving settings file "C:\Users\esara\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:05.678498          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_1fe1fd4c93af8859\boinc_1fe1fd4c93af8859.vbox" with version "1.16-windows"
00:00:05.799652          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:05.801341          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:05.801525          Saving settings file "C:\Users\esara\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:05.813559          Saving settings file "C:\Users\esara\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:05.823769          Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_180e1713f56c994a\boinc_180e1713f56c994a.vbox" with version "1.16-windows"
00:00:05.900259          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:05.901930          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:05.902122          Saving settings file "C:\Users\esara\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:05.915902          Saving settings file "C:\Users\esara\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:05.925901          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_1fe1fd4c93af8859\boinc_1fe1fd4c93af8859.vbox" with version "1.16-windows"
00:00:06.077416          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.078085          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.078913          Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_180e1713f56c994a\boinc_180e1713f56c994a.vbox" with version "1.16-windows"
00:00:06.175909          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_1fe1fd4c93af8859\boinc_1fe1fd4c93af8859.vbox" with version "1.16-windows"
00:00:06.322588          Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_180e1713f56c994a\boinc_180e1713f56c994a.vbox" with version "1.16-windows"
00:00:06.440918          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_1fe1fd4c93af8859\boinc_1fe1fd4c93af8859.vbox" with version "1.16-windows"
00:00:06.570028          Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_180e1713f56c994a\boinc_180e1713f56c994a.vbox" with version "1.16-windows"
00:00:06.679230          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.679417          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.690899          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:06.836200          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.836377          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.847004          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:06.934554          Launched VM: 63007216 pid: 4108 (0x100c) frontend: headless name: boinc_1fe1fd4c93af8859
00:00:07.095487          Launched VM: 63035328 pid: 11604 (0x2d54) frontend: headless name: boinc_180e1713f56c994a
00:00:09.354230          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_1fe1fd4c93af8859\boinc_1fe1fd4c93af8859.vbox" with version "1.16-windows"
00:00:09.435508          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:09.493008          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_1fe1fd4c93af8859\boinc_1fe1fd4c93af8859.vbox" with version "1.16-windows"
00:00:09.520130          Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_180e1713f56c994a\boinc_180e1713f56c994a.vbox" with version "1.16-windows"
00:00:09.589155          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:09.671492          Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_180e1713f56c994a\boinc_180e1713f56c994a.vbox" with version "1.16-windows"
00:00:09.768143          Saving settings file "C:\Users\esara\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:09.914458          Saving settings file "C:\Users\esara\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:15.214635 main     VirtualBox: object deletion starts
00:00:15.215024 main     HostDnsMonitor: shutting down ...
00:00:15.215072 main     HostDnsMonitor: shut down
00:00:15.217015 Watcher  ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0
00:00:15.217147 main     VirtualBox: object deleted

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

rollers:   8
Maximum virtio-scsi Port count:         256
Maximum Devices per virtio-scsi Port:   1
Maximum PIIX3 Floppy Controllers:1
Maximum ICH9 Floppy Controllers: 1
Maximum Floppy Port count:       1
Maximum Devices per Floppy Port: 2
Default machine folder:          C:\Users\esara\VirtualBox VMs
Raw-mode Supported:              no
Exclusive HW virtualization use: off
Default hard disk format:        VDI
VRDE auth library:               VBoxAuth
Webservice auth. library:        VBoxAuth
Remote desktop ExtPack:          
Log history count:               3
Default frontend:                
Default audio driver:            DirectSound
Autostart database path:         
Default Guest Additions ISO:     C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso
Logging Level:                   all
Proxy Mode:                      System
Proxy URL:                       

2020-07-11 00:38:02 (8700): 
Command: VBoxManage -q list hostinfo 
Exit Code: 0
Output:
Host Information:

Host time: 2020-07-10T21:38:02.010000000Z
Processor online count: 12
Processor count: 12
Processor online core count: 6
Processor core count: 6
Processor supports HW virtualization: no
Processor supports PAE: yes
Processor supports long mode: yes
Processor supports nested paging: no
Processor supports unrestricted guest: no
Processor supports nested HW virtualization: no
Processor#0 speed: unknown
Processor#0 description: AMD Ryzen 5 3600X 6-Core Processor
Processor#1 speed: unknown
Processor#1 description: AMD Ryzen 5 3600X 6-Core Processor
Processor#2 speed: unknown
Processor#2 description: AMD Ryzen 5 3600X 6-Core Processor
Processor#3 speed: unknown
Processor#3 description: AMD Ryzen 5 3600X 6-Core Processor
Processor#4 speed: unknown
Processor#4 description: AMD Ryzen 5 3600X 6-Core Processor
Processor#5 speed: unknown
Processor#5 description: AMD Ryzen 5 3600X 6-Core Processor
Processor#6 speed: unknown
Processor#6 description: AMD Ryzen 5 3600X 6-Core Processor
Processor#7 speed: unknown
Processor#7 description: AMD Ryzen 5 3600X 6-Core Processor
Processor#8 speed: unknown
Processor#8 description: AMD Ryzen 5 3600X 6-Core Processor
Processor#9 speed: unknown
Processor#9 description: AMD Ryzen 5 3600X 6-Core Processor
Processor#10 speed: unknown
Processor#10 description: AMD Ryzen 5 3600X 6-Core Processor
Processor#11 speed: unknown
Processor#11 description: AMD Ryzen 5 3600X 6-Core Processor
Memory size: 16332 MByte
Memory available: 10024 MByte
Operating system: Windows 10
Operating system version: 10.0.20161

2020-07-11 00:38:02 (8700): 
Command: VBoxManage -q showvminfo "boinc_180e1713f56c994a" --machinereadable 
Exit Code: -2135228415
Output:
VBoxManage.exe: error: Could not find a registered machine named 'boinc_180e1713f56c994a'
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown
VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2699 of file VBoxManageInfo.cpp

2020-07-11 00:38:02 (8700): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\7/vm_image.vdi" 
Exit Code: -2135228412
Output:
VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\7\vm_image.vdi' (VERR_FILE_NOT_FOUND)
VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp

2020-07-11 00:38:03 (8700): 
Command: VBoxManage -q createvm --name "boinc_180e1713f56c994a" --basefolder "C:\ProgramData\BOINC\slots\7" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_180e1713f56c994a' is created and registered.
UUID: 76c740ed-ff43-4274-9db6-ef0cdeec104d
Settings file: 'C:\ProgramData\BOINC\slots\7\boinc_180e1713f56c994a\boinc_180e1713f56c994a.vbox'

2020-07-11 00:38:03 (8700): 
Command: VBoxManage -q modifyvm "boinc_180e1713f56c994a" --description "07843405_31_1" 
Exit Code: 0
Output:

2020-07-11 00:38:03 (8700): 
Command: VBoxManage -q modifyvm "boinc_180e1713f56c994a" --memory 3072 
Exit Code: 0
Output:

2020-07-11 00:38:03 (8700): 
Command: VBoxManage -q modifyvm "boinc_180e1713f56c994a" --cpus 1 
Exit Code: 0
Output:

2020-07-11 00:38:04 (8700): 
Command: VBoxManage -q modifyvm "boinc_180e1713f56c994a" --acpi on --ioapic on 
Exit Code: 0
Output:

2020-07-11 00:38:04 (8700): 
Command: VBoxManage -q modifyvm "boinc_180e1713f56c994a" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2020-07-11 00:38:04 (8700): 
Command: VBoxManage -q modifyvm "boinc_180e1713f56c994a" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2020-07-11 00:38:04 (8700): 
Command: VBoxManage -q modifyvm "boinc_180e1713f56c994a" --cableconnected1 on 
Exit Code: 0
Output:

2020-07-11 00:38:05 (8700): 
Command: VBoxManage -q modifyvm "boinc_180e1713f56c994a" --usb off 
Exit Code: 0
Output:

2020-07-11 00:38:05 (8700): 
Command: VBoxManage -q modifyvm "boinc_180e1713f56c994a" --uart1 off --uart2 off 
Exit Code: 0
Output:

2020-07-11 00:38:05 (8700): 
Command: VBoxManage -q modifyvm "boinc_180e1713f56c994a" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2020-07-11 00:38:05 (8700): 
Command: VBoxManage -q modifyvm "boinc_180e1713f56c994a" --audio none 
Exit Code: 0
Output:

2020-07-11 00:38:06 (8700): 
Command: VBoxManage -q modifyvm "boinc_180e1713f56c994a" --clipboard disabled 
Exit Code: 0
Output:

2020-07-11 00:38:06 (8700): 
Command: VBoxManage -q modifyvm "boinc_180e1713f56c994a" --draganddrop disabled 
Exit Code: 0
Output:

2020-07-11 00:38:06 (8700): 
Command: VBoxManage -q storagectl "boinc_180e1713f56c994a" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2020-07-11 00:38:07 (8700): 
Command: VBoxManage -q storageattach "boinc_180e1713f56c994a" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\ProgramData\BOINC\slots\7/vm_isocontext.iso" 
Exit Code: 0
Output:

2020-07-11 00:38:07 (8700): 
Command: VBoxManage -q storageattach "boinc_180e1713f56c994a" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2020-07-11 00:38:07 (8700): 
Command: VBoxManage -q bandwidthctl "boinc_180e1713f56c994a" add "boinc_180e1713f56c994a_net" --type network --limit 1024G 
Exit Code: 0
Output:

2020-07-11 00:38:07 (8700): 
Command: VBoxManage -q sharedfolder add "boinc_180e1713f56c994a" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\7/shared"
Exit Code: 0
Output:

2020-07-11 00:38:10 (8700): 
Command: VBoxManage -q startvm "boinc_180e1713f56c994a" --type headless
Exit Code: -2147467259
Output:
Waiting for VM "boinc_180e1713f56c994a" to power on...
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: AMD-V is disabled in the BIOS (or by the host OS) (VERR_SVM_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole

2020-07-11 00:38:10 (8700): 
Command: VBoxManage -q snapshot "boinc_180e1713f56c994a" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2020-07-11 00:38:10 (8700): 
Command: VBoxManage -q bandwidthctl "boinc_180e1713f56c994a" remove "boinc_180e1713f56c994a_net" 
Exit Code: 0
Output:

2020-07-11 00:38:11 (8700): 
Command: VBoxManage -q unregistervm "boinc_180e1713f56c994a" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

2020-07-11 00:38:11 (8700): 
Command: VBoxManage -q closemedium dvd "C:\ProgramData\BOINC\slots\7/vm_isocontext.iso" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

00:38:16 (8700): called boinc_finish(-2147467259)

</stderr_txt>
]]>


©2024 COPYRIGHT 2017-2018 NCN