Task 8866821

Name 07847882_14_1
Workunit 7105316
Created 14 Jul 2020, 12:05:29 UTC
Sent 14 Jul 2020, 13:53:39 UTC
Report deadline 19 Jul 2020, 13:53:39 UTC
Received 15 Jul 2020, 17:14:52 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status -2147467259 (0x80004005) Unknown error code
Computer ID 5138
Run time 15 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 4.44 GFLOPS
Application version boinc2docker v1.12 (vbox64_mt)
windows_x86_64
Peak working set size 10.79 MB
Peak swap size 6.45 MB
Peak disk usage 230.62 MB

Stderr output

<core_client_version>7.16.7</core_client_version>
<![CDATA[
<message>
Unbekannter Fehler
 (0x80004005) - exit code -2147467259 (0x80004005)</message>
<stderr_txt>
2020-07-14 16:11:55 (6172): vboxwrapper (7.9.26200): starting
2020-07-14 16:11:56 (6172): Feature: Checkpoint interval offset (369 seconds)
2020-07-14 16:11:56 (6172): Detected: VirtualBox VboxManage Interface (Version: 6.1.10)
2020-07-14 16:11:56 (6172): Detected: Minimum checkpoint interval (600.000000 seconds)
2020-07-14 16:11:57 (6172): Create VM. (boinc_cb52452a54ab5f60, slot#2)
2020-07-14 16:11:57 (6172): Updating drive controller type and model for desired configuration.
2020-07-14 16:11:57 (6172): Setting Memory Size for VM. (3072MB)
2020-07-14 16:11:58 (6172): Setting CPU Count for VM. (1)
2020-07-14 16:11:58 (6172): Setting Chipset Options for VM.
2020-07-14 16:11:58 (6172): Setting Boot Options for VM.
2020-07-14 16:11:59 (6172): Setting Network Configuration for NAT.
2020-07-14 16:11:59 (6172): Enabling VM Network Access.
2020-07-14 16:11:59 (6172): Disabling USB Support for VM.
2020-07-14 16:11:59 (6172): Disabling COM Port Support for VM.
2020-07-14 16:12:00 (6172): Disabling LPT Port Support for VM.
2020-07-14 16:12:00 (6172): Disabling Audio Support for VM.
2020-07-14 16:12:00 (6172): Disabling Clipboard Support for VM.
2020-07-14 16:12:00 (6172): Disabling Drag and Drop Support for VM.
2020-07-14 16:12:01 (6172): Adding storage controller(s) to VM.
2020-07-14 16:12:01 (6172): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso)
2020-07-14 16:12:01 (6172): Adding VirtualBox Guest Additions to VM.
2020-07-14 16:12:01 (6172): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2020-07-14 16:12:02 (6172): Enabling shared directory for VM.
2020-07-14 16:12:02 (6172): Starting VM using VboxManage interface. (boinc_cb52452a54ab5f60, slot#2)
2020-07-14 17:00:01 (6172): Error in start VM for VM: -2147467259
Command:
VBoxManage -q startvm "boinc_cb52452a54ab5f60" --type headless
Output:
Waiting for VM "boinc_cb52452a54ab5f60" to power on...
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: AMD-V is disabled in the BIOS (or by the host OS) (VERR_SVM_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole

2020-07-14 17:00:01 (6172): VM failed to start.
2020-07-14 17:00:01 (6172): Could not start 
2020-07-14 17:00:01 (6172): Powering off VM.
2020-07-14 17:00:01 (6172): Deregistering VM. (boinc_cb52452a54ab5f60, slot#2)
2020-07-14 17:00:01 (6172): Removing network bandwidth throttle group from VM.
2020-07-14 17:00:01 (6172): Removing VM from VirtualBox.
2020-07-14 17:00:01 (6172): Removing virtual ISO 9660 disk from VirtualBox.

    Hypervisor System Log:

00:00:05.466386          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:05.466511          Saving settings file "C:\Users\Bjoern_Std\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:05.474879          Saving settings file "C:\Users\Bjoern_Std\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:05.478494          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_cb52452a54ab5f60\boinc_cb52452a54ab5f60.vbox" with version "1.16-windows"
00:00:05.620655          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:05.621927          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:05.622046          Saving settings file "C:\Users\Bjoern_Std\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:05.630275          Saving settings file "C:\Users\Bjoern_Std\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:05.633832          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_c9f65169a50b4f27\boinc_c9f65169a50b4f27.vbox" with version "1.16-windows"
00:00:05.729972          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:05.730397          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:05.730823          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_cb52452a54ab5f60\boinc_cb52452a54ab5f60.vbox" with version "1.16-windows"
00:00:05.886243          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_c9f65169a50b4f27\boinc_c9f65169a50b4f27.vbox" with version "1.16-windows"
00:00:06.004214          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_cb52452a54ab5f60\boinc_cb52452a54ab5f60.vbox" with version "1.16-windows"
00:00:06.193515          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_c9f65169a50b4f27\boinc_c9f65169a50b4f27.vbox" with version "1.16-windows"
00:00:06.271756          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_cb52452a54ab5f60\boinc_cb52452a54ab5f60.vbox" with version "1.16-windows"
00:00:06.548153 MainPower Host suspending: Paused 0 VMs
00:00:06.594475          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.594634          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.594656          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.594789          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.603618          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:06.603766          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:06.727048          Launched VM: 61504336 pid: 8776 (0x2248) frontend: headless name: boinc_c9f65169a50b4f27
00:00:06.837521          Launched VM: 61561744 pid: 9940 (0x26d4) frontend: headless name: boinc_cb52452a54ab5f60
00:00:08.648765          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_c9f65169a50b4f27\boinc_c9f65169a50b4f27.vbox" with version "1.16-windows"
00:48:04.329189          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:48:04.432345          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_c9f65169a50b4f27\boinc_c9f65169a50b4f27.vbox" with version "1.16-windows"
00:48:04.690219          Saving settings file "C:\Users\Bjoern_Std\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:48:04.946885          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_cb52452a54ab5f60\boinc_cb52452a54ab5f60.vbox" with version "1.16-windows"
00:48:05.055937          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:48:05.131270          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_cb52452a54ab5f60\boinc_cb52452a54ab5f60.vbox" with version "1.16-windows"
00:48:05.411144          Saving settings file "C:\Users\Bjoern_Std\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:48:06.529338 MainPower Host resumed: Resumed 0 VMs
00:48:07.220015 USBPROXY usbLibGetDevices: Starting USB device enumeration
00:48:07.664951 USBPROXY usbLibGetDevices: Found 4 USB devices, 0 captured
00:48:07.934836 dns-monitor HostDnsMonitor: updating information
00:48:07.934891 dns-monitor HostDnsMonitor: old information
00:48:07.934898 dns-monitor   server 1: 9.9.9.9
00:48:07.934904 dns-monitor   server 2: 192.168.0.1
00:48:07.934910 dns-monitor   domain: home
00:48:07.934915 dns-monitor   no search string entries
00:48:07.934921 dns-monitor HostDnsMonitor: new information
00:48:07.934926 dns-monitor   no server entries
00:48:07.934931 dns-monitor   no domain set
00:48:07.934936 dns-monitor   no search string entries
00:48:08.423690 USBPROXY usbLibGetDevices: Starting USB device enumeration
00:48:08.423918 USBPROXY Getting USB descriptor (id 0) failed (dwErr=31) on hub USB#ROOT_HUB30#5&1171eda9&0&0#{f18a0e88-c30c-11d0-8815-00a0c906bed8} port 10
00:48:08.653883 USBPROXY usbLibGetDevices: Found 4 USB devices, 0 captured
00:48:09.541029 USBPROXY usbLibGetDevices: Starting USB device enumeration
00:48:09.541294 USBPROXY Getting USB descriptor (id 0) failed (dwErr=31) on hub USB#ROOT_HUB30#5&1171eda9&0&0#{f18a0e88-c30c-11d0-8815-00a0c906bed8} port 10
00:48:09.727146 USBPROXY usbLibGetDevices: Found 4 USB devices, 0 captured
00:48:10.694694 main     VirtualBox: object deletion starts
00:48:10.695138 main     HostDnsMonitor: shutting down ...
00:48:10.695161 main     HostDnsMonitor: shut down
00:48:10.696218 Watcher  ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0
00:48:10.696329 main     VirtualBox: object deleted

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

      VDI
VRDE auth library:               VBoxAuth
Webservice auth. library:        VBoxAuth
Remote desktop ExtPack:          
Log history count:               3
Default frontend:                
Default audio driver:            DirectSound
Autostart database path:         
Default Guest Additions ISO:     C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso
Logging Level:                   all
Proxy Mode:                      System
Proxy URL:                       

2020-07-14 16:11:56 (6172): 
Command: VBoxManage -q list hostinfo 
Exit Code: 0
Output:
Host Information:

Host time: 2020-07-14T14:11:56.602000000Z
Processor online count: 16
Processor count: 16
Processor online core count: 8
Processor core count: 8
Processor supports HW virtualization: no
Processor supports PAE: yes
Processor supports long mode: yes
Processor supports nested paging: no
Processor supports unrestricted guest: no
Processor supports nested HW virtualization: no
Processor#0 speed: unknown
Processor#0 description: AMD Ryzen 7 2700 Eight-Core Processor
Processor#1 speed: unknown
Processor#1 description: AMD Ryzen 7 2700 Eight-Core Processor
Processor#2 speed: unknown
Processor#2 description: AMD Ryzen 7 2700 Eight-Core Processor
Processor#3 speed: unknown
Processor#3 description: AMD Ryzen 7 2700 Eight-Core Processor
Processor#4 speed: unknown
Processor#4 description: AMD Ryzen 7 2700 Eight-Core Processor
Processor#5 speed: unknown
Processor#5 description: AMD Ryzen 7 2700 Eight-Core Processor
Processor#6 speed: unknown
Processor#6 description: AMD Ryzen 7 2700 Eight-Core Processor
Processor#7 speed: unknown
Processor#7 description: AMD Ryzen 7 2700 Eight-Core Processor
Processor#8 speed: unknown
Processor#8 description: AMD Ryzen 7 2700 Eight-Core Processor
Processor#9 speed: unknown
Processor#9 description: AMD Ryzen 7 2700 Eight-Core Processor
Processor#10 speed: unknown
Processor#10 description: AMD Ryzen 7 2700 Eight-Core Processor
Processor#11 speed: unknown
Processor#11 description: AMD Ryzen 7 2700 Eight-Core Processor
Processor#12 speed: unknown
Processor#12 description: AMD Ryzen 7 2700 Eight-Core Processor
Processor#13 speed: unknown
Processor#13 description: AMD Ryzen 7 2700 Eight-Core Processor
Processor#14 speed: unknown
Processor#14 description: AMD Ryzen 7 2700 Eight-Core Processor
Processor#15 speed: unknown
Processor#15 description: AMD Ryzen 7 2700 Eight-Core Processor
Memory size: 16333 MByte
Memory available: 10408 MByte
Operating system: Windows 10
Operating system version: 10.0.18363

2020-07-14 16:11:57 (6172): 
Command: VBoxManage -q showvminfo "boinc_cb52452a54ab5f60" --machinereadable 
Exit Code: -2135228415
Output:
VBoxManage.exe: error: Could not find a registered machine named 'boinc_cb52452a54ab5f60'
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown
VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2699 of file VBoxManageInfo.cpp

2020-07-14 16:11:57 (6172): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\2/vm_image.vdi" 
Exit Code: -2135228412
Output:
VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\2\vm_image.vdi' (VERR_FILE_NOT_FOUND)
VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp

2020-07-14 16:11:57 (6172): 
Command: VBoxManage -q createvm --name "boinc_cb52452a54ab5f60" --basefolder "C:\ProgramData\BOINC\slots\2" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_cb52452a54ab5f60' is created and registered.
UUID: d0249417-7ec2-4f70-99af-6ffd94b11ba8
Settings file: 'C:\ProgramData\BOINC\slots\2\boinc_cb52452a54ab5f60\boinc_cb52452a54ab5f60.vbox'

2020-07-14 16:11:57 (6172): 
Command: VBoxManage -q modifyvm "boinc_cb52452a54ab5f60" --description "07847882_14_1" 
Exit Code: 0
Output:

2020-07-14 16:11:58 (6172): 
Command: VBoxManage -q modifyvm "boinc_cb52452a54ab5f60" --memory 3072 
Exit Code: 0
Output:

2020-07-14 16:11:58 (6172): 
Command: VBoxManage -q modifyvm "boinc_cb52452a54ab5f60" --cpus 1 
Exit Code: 0
Output:

2020-07-14 16:11:58 (6172): 
Command: VBoxManage -q modifyvm "boinc_cb52452a54ab5f60" --acpi on --ioapic on 
Exit Code: 0
Output:

2020-07-14 16:11:59 (6172): 
Command: VBoxManage -q modifyvm "boinc_cb52452a54ab5f60" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2020-07-14 16:11:59 (6172): 
Command: VBoxManage -q modifyvm "boinc_cb52452a54ab5f60" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2020-07-14 16:11:59 (6172): 
Command: VBoxManage -q modifyvm "boinc_cb52452a54ab5f60" --cableconnected1 on 
Exit Code: 0
Output:

2020-07-14 16:11:59 (6172): 
Command: VBoxManage -q modifyvm "boinc_cb52452a54ab5f60" --usb off 
Exit Code: 0
Output:

2020-07-14 16:12:00 (6172): 
Command: VBoxManage -q modifyvm "boinc_cb52452a54ab5f60" --uart1 off --uart2 off 
Exit Code: 0
Output:

2020-07-14 16:12:00 (6172): 
Command: VBoxManage -q modifyvm "boinc_cb52452a54ab5f60" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2020-07-14 16:12:00 (6172): 
Command: VBoxManage -q modifyvm "boinc_cb52452a54ab5f60" --audio none 
Exit Code: 0
Output:

2020-07-14 16:12:00 (6172): 
Command: VBoxManage -q modifyvm "boinc_cb52452a54ab5f60" --clipboard disabled 
Exit Code: 0
Output:

2020-07-14 16:12:01 (6172): 
Command: VBoxManage -q modifyvm "boinc_cb52452a54ab5f60" --draganddrop disabled 
Exit Code: 0
Output:

2020-07-14 16:12:01 (6172): 
Command: VBoxManage -q storagectl "boinc_cb52452a54ab5f60" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2020-07-14 16:12:01 (6172): 
Command: VBoxManage -q storageattach "boinc_cb52452a54ab5f60" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\ProgramData\BOINC\slots\2/vm_isocontext.iso" 
Exit Code: 0
Output:

2020-07-14 16:12:01 (6172): 
Command: VBoxManage -q storageattach "boinc_cb52452a54ab5f60" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2020-07-14 16:12:02 (6172): 
Command: VBoxManage -q bandwidthctl "boinc_cb52452a54ab5f60" add "boinc_cb52452a54ab5f60_net" --type network --limit 1024G 
Exit Code: 0
Output:

2020-07-14 16:12:02 (6172): 
Command: VBoxManage -q sharedfolder add "boinc_cb52452a54ab5f60" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\2/shared"
Exit Code: 0
Output:

2020-07-14 17:00:01 (6172): 
Command: VBoxManage -q startvm "boinc_cb52452a54ab5f60" --type headless
Exit Code: -2147467259
Output:
Waiting for VM "boinc_cb52452a54ab5f60" to power on...
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: AMD-V is disabled in the BIOS (or by the host OS) (VERR_SVM_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole

2020-07-14 17:00:01 (6172): 
Command: VBoxManage -q snapshot "boinc_cb52452a54ab5f60" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2020-07-14 17:00:01 (6172): 
Command: VBoxManage -q bandwidthctl "boinc_cb52452a54ab5f60" remove "boinc_cb52452a54ab5f60_net" 
Exit Code: 0
Output:

2020-07-14 17:00:01 (6172): 
Command: VBoxManage -q unregistervm "boinc_cb52452a54ab5f60" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

2020-07-14 17:00:01 (6172): 
Command: VBoxManage -q closemedium dvd "C:\ProgramData\BOINC\slots\2/vm_isocontext.iso" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

17:00:07 (6172): called boinc_finish(-2147467259)

</stderr_txt>
]]>


©2024 COPYRIGHT 2017-2018 NCN