Name | 07860867_14_1 |
Workunit | 7230188 |
Created | 25 Jul 2020, 19:44:00 UTC |
Sent | 25 Jul 2020, 20:12:10 UTC |
Report deadline | 30 Jul 2020, 20:12:10 UTC |
Received | 26 Jul 2020, 0:19:26 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | 1 (0x00000001) Unknown error code |
Computer ID | 6822 |
Run time | 27 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 3.39 GFLOPS |
Application version | boinc2docker v1.12 (vbox64_mt) windows_x86_64 |
Peak working set size | 10.71 MB |
Peak swap size | 6.41 MB |
Peak disk usage | 227.73 MB |
<core_client_version>7.16.5</core_client_version> <![CDATA[ <message> Incorrect function. (0x1) - exit code 1 (0x1)</message> <stderr_txt> 2020-07-25 16:15:43 (58160): vboxwrapper (7.9.26200): starting 2020-07-25 16:15:47 (58160): Feature: Checkpoint interval offset (478 seconds) 2020-07-25 16:15:47 (58160): Detected: VirtualBox VboxManage Interface (Version: 6.0.14) 2020-07-25 16:15:47 (58160): Detected: Minimum checkpoint interval (600.000000 seconds) 2020-07-25 16:15:48 (58160): Create VM. (boinc_6e809e0c4094b50c, slot#3) 2020-07-25 16:15:48 (58160): Updating drive controller type and model for desired configuration. 2020-07-25 16:15:49 (58160): Setting Memory Size for VM. (3072MB) 2020-07-25 16:15:49 (58160): Setting CPU Count for VM. (1) 2020-07-25 16:15:49 (58160): Setting Chipset Options for VM. 2020-07-25 16:15:49 (58160): Setting Boot Options for VM. 2020-07-25 16:15:50 (58160): Setting Network Configuration for NAT. 2020-07-25 16:15:50 (58160): Enabling VM Network Access. 2020-07-25 16:15:51 (58160): Disabling USB Support for VM. 2020-07-25 16:15:51 (58160): Disabling COM Port Support for VM. 2020-07-25 16:15:51 (58160): Disabling LPT Port Support for VM. 2020-07-25 16:15:51 (58160): Disabling Audio Support for VM. 2020-07-25 16:15:52 (58160): Disabling Clipboard Support for VM. 2020-07-25 16:15:54 (58160): Disabling Drag and Drop Support for VM. 2020-07-25 16:15:54 (58160): Adding storage controller(s) to VM. 2020-07-25 16:15:55 (58160): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso) 2020-07-25 16:15:55 (58160): Adding VirtualBox Guest Additions to VM. 2020-07-25 16:15:56 (58160): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2020-07-25 16:15:57 (58160): Enabling shared directory for VM. 2020-07-25 16:15:58 (58160): Starting VM using VboxManage interface. (boinc_6e809e0c4094b50c, slot#3) 2020-07-25 16:16:01 (58160): Error in start VM for VM: 1 Command: VBoxManage -q startvm "boinc_6e809e0c4094b50c" --type headless Output: Waiting for VM "boinc_6e809e0c4094b50c" to power on... VBoxManage.exe: error: The virtual machine 'boinc_6e809e0c4094b50c' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\3\boinc_6e809e0c4094b50c\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine 2020-07-25 16:16:01 (58160): VM failed to start. 2020-07-25 16:16:01 (58160): Could not start 2020-07-25 16:16:01 (58160): Powering off VM. 2020-07-25 16:16:01 (58160): Deregistering VM. (boinc_6e809e0c4094b50c, slot#3) 2020-07-25 16:16:01 (58160): Removing network bandwidth throttle group from VM. 2020-07-25 16:16:02 (58160): Removing VM from VirtualBox. 2020-07-25 16:16:02 (58160): Removing virtual ISO 9660 disk from VirtualBox. Hypervisor System Log: 00:00:01.622318 netIfIsWireless: CreateFile on '\\.\{731866C4-1B29-4B30-A3A1-71123BFCD229}' failed with rcWin=2 (0x2) - ignoring 00:00:01.670546 netIfIsWireless: CreateFile on '\\.\{1EBD3621-8A2A-47AB-BE22-148E7FEF5235}' failed with rcWin=2 (0x2) - ignoring 00:00:01.735821 HostDnsMonitor::updateInfo 00:00:01.735872 HostDnsMonitor: old information 00:00:01.735876 no server entries 00:00:01.735878 no domain set 00:00:01.735878 no search string entries 00:00:01.735879 HostDnsMonitor: new information 00:00:01.735879 server 1: 192.168.1.1 00:00:01.735880 no domain set 00:00:01.735880 no search string entries 00:00:01.932880 SUPR0QueryVTCaps -> VERR_SVM_DISABLED 00:00:01.935667 VD: VDInit finished with VINF_SUCCESS 00:00:01.940479 VirtualBox: object created 00:00:02.853088 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={Could not find a registered machine named 'boinc_6e809e0c4094b50c'}, preserve=false aResultDetail=0 00:00:03.209828 ERROR [COM]: aRC=VBOX_E_FILE_ERROR (0x80bb0004) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Could not find file for the medium 'C:\ProgramData\BOINC\slots\3\vm_image.vdi' (VERR_FILE_NOT_FOUND)}, preserve=false aResultDetail=-102 00:00:03.726090 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_6e809e0c4094b50c\boinc_6e809e0c4094b50c.vbox" with version "1.16-windows" 00:00:03.737573 Saving settings file "C:\Users\Jim\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:03.995786 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_6e809e0c4094b50c\boinc_6e809e0c4094b50c.vbox" with version "1.16-windows" 00:00:04.345815 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_6e809e0c4094b50c\boinc_6e809e0c4094b50c.vbox" with version "1.16-windows" 00:00:04.611316 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_6e809e0c4094b50c\boinc_6e809e0c4094b50c.vbox" with version "1.16-windows" 00:00:04.900556 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_6e809e0c4094b50c\boinc_6e809e0c4094b50c.vbox" with version "1.16-windows" 00:00:05.201504 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_6e809e0c4094b50c\boinc_6e809e0c4094b50c.vbox" with version "1.16-windows" 00:00:05.482372 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_6e809e0c4094b50c\boinc_6e809e0c4094b50c.vbox" with version "1.16-windows" 00:00:05.777504 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_6e809e0c4094b50c\boinc_6e809e0c4094b50c.vbox" with version "1.16-windows" 00:00:06.312513 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_6e809e0c4094b50c\boinc_6e809e0c4094b50c.vbox" with version "1.16-windows" 00:00:06.595388 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_6e809e0c4094b50c\boinc_6e809e0c4094b50c.vbox" with version "1.16-windows" 00:00:06.882787 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_6e809e0c4094b50c\boinc_6e809e0c4094b50c.vbox" with version "1.16-windows" 00:00:07.209966 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_6e809e0c4094b50c\boinc_6e809e0c4094b50c.vbox" with version "1.16-windows" 00:00:08.418820 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_6e809e0c4094b50c\boinc_6e809e0c4094b50c.vbox" with version "1.16-windows" 00:00:09.925018 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_6e809e0c4094b50c\boinc_6e809e0c4094b50c.vbox" with version "1.16-windows" 00:00:10.235743 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_6e809e0c4094b50c\boinc_6e809e0c4094b50c.vbox" with version "1.16-windows" 00:00:10.547758 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:10.557424 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:10.557853 Saving settings file "C:\Users\Jim\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:10.573682 Saving settings file "C:\Users\Jim\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:10.590354 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_6e809e0c4094b50c\boinc_6e809e0c4094b50c.vbox" with version "1.16-windows" 00:00:11.372189 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:11.383736 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:11.384161 Saving settings file "C:\Users\Jim\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:11.408630 Saving settings file "C:\Users\Jim\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:11.424054 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_6e809e0c4094b50c\boinc_6e809e0c4094b50c.vbox" with version "1.16-windows" 00:00:12.145902 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_6e809e0c4094b50c\boinc_6e809e0c4094b50c.vbox" with version "1.16-windows" 00:00:12.713342 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_6e809e0c4094b50c\boinc_6e809e0c4094b50c.vbox" with version "1.16-windows" 00:00:13.334834 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:13.335107 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:13.355419 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:16.322100 Watcher ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={MachineWrap} aText={The virtual machine 'boinc_6e809e0c4094b50c' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\3\boinc_6e809e0c4094b50c\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0 00:00:16.687495 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:17.007993 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_6e809e0c4094b50c\boinc_6e809e0c4094b50c.vbox" with version "1.16-windows" 00:00:17.559426 Saving settings file "C:\Users\Jim\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:23.093394 main VirtualBox: object deletion starts 00:00:23.097832 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:23.098160 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: Network Adapter count: 8 Maximum ICH9 Network Adapter count: 36 Maximum PIIX3 IDE Controllers: 1 Maximum ICH9 IDE Controllers: 1 Maximum IDE Port count: 2 Maximum Devices per IDE Port: 2 Maximum PIIX3 SATA Controllers: 1 Maximum ICH9 SATA Controllers: 8 Maximum SATA Port count: 30 Maximum Devices per SATA Port: 1 Maximum PIIX3 SCSI Controllers: 1 Maximum ICH9 SCSI Controllers: 8 Maximum SCSI Port count: 16 Maximum Devices per SCSI Port: 1 Maximum SAS PIIX3 Controllers: 1 Maximum SAS ICH9 Controllers: 8 Maximum SAS Port count: 255 Maximum Devices per SAS Port: 1 Maximum NVMe PIIX3 Controllers: 1 Maximum NVMe ICH9 Controllers: 8 Maximum NVMe Port count: 255 Maximum Devices per NVMe Port: 1 Maximum PIIX3 Floppy Controllers:1 Maximum ICH9 Floppy Controllers: 1 Maximum Floppy Port count: 1 Maximum Devices per Floppy Port: 2 Default machine folder: C:\Users\Jim\VirtualBox VMs Raw-mode Supported: yes Exclusive HW virtualization use: off Default hard disk format: VDI VRDE auth library: VBoxAuth Webservice auth. library: VBoxAuth Remote desktop ExtPack: Log history count: 3 Default frontend: Default audio driver: DirectSound Autostart database path: Default Guest Additions ISO: C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso Logging Level: all Proxy Mode: System Proxy URL: 2020-07-25 16:15:47 (58160): Command: VBoxManage -q list hostinfo Exit Code: 0 Output: Host Information: Host time: 2020-07-25T20:15:47.487000000Z Processor online count: 4 Processor count: 4 Processor online core count: 4 Processor core count: 4 Processor supports HW virtualization: no Processor supports PAE: yes Processor supports long mode: yes Processor supports nested paging: no Processor#0 speed: unknown Processor#0 description: AMD PRO A12-8870 R7, 12 COMPUTE CORES 4C+8G Processor#1 speed: unknown Processor#1 description: AMD PRO A12-8870 R7, 12 COMPUTE CORES 4C+8G Processor#2 speed: unknown Processor#2 description: AMD PRO A12-8870 R7, 12 COMPUTE CORES 4C+8G Processor#3 speed: unknown Processor#3 description: AMD PRO A12-8870 R7, 12 COMPUTE CORES 4C+8G Memory size: 7610 MByte Memory available: 2626 MByte Operating system: Windows 10 Operating system version: 10.0.18363 2020-07-25 16:15:47 (58160): Command: VBoxManage -q showvminfo "boinc_6e809e0c4094b50c" --machinereadable Exit Code: -2135228415 Output: VBoxManage.exe: error: Could not find a registered machine named 'boinc_6e809e0c4094b50c' VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2621 of file VBoxManageInfo.cpp 2020-07-25 16:15:48 (58160): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\3/vm_image.vdi" Exit Code: -2135228412 Output: VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\3\vm_image.vdi' (VERR_FILE_NOT_FOUND) VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp 2020-07-25 16:15:48 (58160): Command: VBoxManage -q createvm --name "boinc_6e809e0c4094b50c" --basefolder "C:\ProgramData\BOINC\slots\3" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_6e809e0c4094b50c' is created and registered. UUID: a5eddad5-f3b0-4391-b0ea-e332ff0f4e99 Settings file: 'C:\ProgramData\BOINC\slots\3\boinc_6e809e0c4094b50c\boinc_6e809e0c4094b50c.vbox' 2020-07-25 16:15:49 (58160): Command: VBoxManage -q modifyvm "boinc_6e809e0c4094b50c" --description "07860867_14_1" Exit Code: 0 Output: 2020-07-25 16:15:49 (58160): Command: VBoxManage -q modifyvm "boinc_6e809e0c4094b50c" --memory 3072 Exit Code: 0 Output: 2020-07-25 16:15:49 (58160): Command: VBoxManage -q modifyvm "boinc_6e809e0c4094b50c" --cpus 1 Exit Code: 0 Output: 2020-07-25 16:15:49 (58160): Command: VBoxManage -q modifyvm "boinc_6e809e0c4094b50c" --acpi on --ioapic on Exit Code: 0 Output: 2020-07-25 16:15:50 (58160): Command: VBoxManage -q modifyvm "boinc_6e809e0c4094b50c" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2020-07-25 16:15:50 (58160): Command: VBoxManage -q modifyvm "boinc_6e809e0c4094b50c" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2020-07-25 16:15:51 (58160): Command: VBoxManage -q modifyvm "boinc_6e809e0c4094b50c" --cableconnected1 on Exit Code: 0 Output: 2020-07-25 16:15:51 (58160): Command: VBoxManage -q modifyvm "boinc_6e809e0c4094b50c" --usb off Exit Code: 0 Output: 2020-07-25 16:15:51 (58160): Command: VBoxManage -q modifyvm "boinc_6e809e0c4094b50c" --uart1 off --uart2 off Exit Code: 0 Output: 2020-07-25 16:15:51 (58160): Command: VBoxManage -q modifyvm "boinc_6e809e0c4094b50c" --lpt1 off --lpt2 off Exit Code: 0 Output: 2020-07-25 16:15:52 (58160): Command: VBoxManage -q modifyvm "boinc_6e809e0c4094b50c" --audio none Exit Code: 0 Output: 2020-07-25 16:15:54 (58160): Command: VBoxManage -q modifyvm "boinc_6e809e0c4094b50c" --clipboard disabled Exit Code: 0 Output: 2020-07-25 16:15:54 (58160): Command: VBoxManage -q modifyvm "boinc_6e809e0c4094b50c" --draganddrop disabled Exit Code: 0 Output: 2020-07-25 16:15:55 (58160): Command: VBoxManage -q storagectl "boinc_6e809e0c4094b50c" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2020-07-25 16:15:55 (58160): Command: VBoxManage -q storageattach "boinc_6e809e0c4094b50c" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\ProgramData\BOINC\slots\3/vm_isocontext.iso" Exit Code: 0 Output: 2020-07-25 16:15:56 (58160): Command: VBoxManage -q storageattach "boinc_6e809e0c4094b50c" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2020-07-25 16:15:57 (58160): Command: VBoxManage -q bandwidthctl "boinc_6e809e0c4094b50c" add "boinc_6e809e0c4094b50c_net" --type network --limit 1024G Exit Code: 0 Output: 2020-07-25 16:15:57 (58160): Command: VBoxManage -q sharedfolder add "boinc_6e809e0c4094b50c" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\3/shared" Exit Code: 0 Output: 2020-07-25 16:16:01 (58160): Command: VBoxManage -q startvm "boinc_6e809e0c4094b50c" --type headless Exit Code: 1 Output: Waiting for VM "boinc_6e809e0c4094b50c" to power on... VBoxManage.exe: error: The virtual machine 'boinc_6e809e0c4094b50c' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\3\boinc_6e809e0c4094b50c\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine 2020-07-25 16:16:01 (58160): Command: VBoxManage -q snapshot "boinc_6e809e0c4094b50c" list Exit Code: -108 Output: This machine does not have any snapshots 2020-07-25 16:16:02 (58160): Command: VBoxManage -q bandwidthctl "boinc_6e809e0c4094b50c" remove "boinc_6e809e0c4094b50c_net" Exit Code: 0 Output: 2020-07-25 16:16:02 (58160): Command: VBoxManage -q unregistervm "boinc_6e809e0c4094b50c" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 2020-07-25 16:16:03 (58160): Command: VBoxManage -q closemedium dvd "C:\ProgramData\BOINC\slots\3/vm_isocontext.iso" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 16:16:08 (58160): called boinc_finish(1) </stderr_txt> ]]>
©2024 COPYRIGHT 2017-2018 NCN