Task 9252208

Name 07879855_07_0
Workunit 7373035
Created 6 Aug 2020, 20:15:08 UTC
Sent 7 Aug 2020, 18:52:11 UTC
Report deadline 12 Aug 2020, 18:52:11 UTC
Received 7 Aug 2020, 20:44:17 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status -2147467259 (0x80004005) Unknown error code
Computer ID 8345
Run time 37 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 4.52 GFLOPS
Application version boinc2docker v1.12 (vbox64_mt)
windows_x86_64
Peak working set size 10.84 MB
Peak swap size 6.45 MB
Peak disk usage 228.11 MB

Stderr output

<core_client_version>7.14.2</core_client_version>
<![CDATA[
<message>
 - exit code -2147467259 (0x80004005)</message>
<stderr_txt>
2020-08-08 02:56:00 (17148): vboxwrapper (7.9.26200): starting
2020-08-08 02:56:00 (17148): Feature: Checkpoint interval offset (426 seconds)
2020-08-08 02:56:00 (17148): Detected: VirtualBox VboxManage Interface (Version: 6.1.6)
2020-08-08 02:56:01 (17148): Detected: Minimum checkpoint interval (600.000000 seconds)
2020-08-08 02:56:02 (17148): Create VM. (boinc_bfaa30f0aac240b7, slot#13)
2020-08-08 02:56:02 (17148): Updating drive controller type and model for desired configuration.
2020-08-08 02:56:03 (17148): Setting Memory Size for VM. (3072MB)
2020-08-08 02:56:04 (17148): Setting CPU Count for VM. (1)
2020-08-08 02:56:05 (17148): Setting Chipset Options for VM.
2020-08-08 02:56:06 (17148): Setting Boot Options for VM.
2020-08-08 02:56:07 (17148): Setting Network Configuration for NAT.
2020-08-08 02:56:08 (17148): Enabling VM Network Access.
2020-08-08 02:56:09 (17148): Disabling USB Support for VM.
2020-08-08 02:56:10 (17148): Disabling COM Port Support for VM.
2020-08-08 02:56:10 (17148): Disabling LPT Port Support for VM.
2020-08-08 02:56:11 (17148): Disabling Audio Support for VM.
2020-08-08 02:56:11 (17148): Disabling Clipboard Support for VM.
2020-08-08 02:56:12 (17148): Disabling Drag and Drop Support for VM.
2020-08-08 02:56:12 (17148): Adding storage controller(s) to VM.
2020-08-08 02:56:13 (17148): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso)
2020-08-08 02:56:13 (17148): Adding VirtualBox Guest Additions to VM.
2020-08-08 02:56:14 (17148): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2020-08-08 02:56:15 (17148): Enabling shared directory for VM.
2020-08-08 02:56:15 (17148): Starting VM using VboxManage interface. (boinc_bfaa30f0aac240b7, slot#13)
2020-08-08 02:56:21 (17148): Error in start VM for VM: -2147467259
Command:
VBoxManage -q startvm "boinc_bfaa30f0aac240b7" --type headless
Output:
Waiting for VM "boinc_bfaa30f0aac240b7" to power on...
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: AMD-V is disabled in the BIOS (or by the host OS) (VERR_SVM_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole

2020-08-08 02:56:21 (17148): VM failed to start.
2020-08-08 02:56:21 (17148): Could not start 
2020-08-08 02:56:21 (17148): Powering off VM.
2020-08-08 02:56:21 (17148): Deregistering VM. (boinc_bfaa30f0aac240b7, slot#13)
2020-08-08 02:56:22 (17148): Removing network bandwidth throttle group from VM.
2020-08-08 02:56:22 (17148): Removing VM from VirtualBox.
2020-08-08 02:56:23 (17148): Removing virtual ISO 9660 disk from VirtualBox.

    Hypervisor System Log:

00:02:22.666598          Saving settings file "C:\Program Files\BOINC\a\slots\13\boinc_bfaa30f0aac240b7\boinc_bfaa30f0aac240b7.vbox" with version "1.16-windows"
00:02:22.995882          Saving settings file "C:\Users\Administrator\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:02:23.082894          Saving settings file "C:\Program Files\BOINC\a\slots\13\boinc_bfaa30f0aac240b7\boinc_bfaa30f0aac240b7.vbox" with version "1.16-windows"
00:02:23.381929          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:02:23.382133          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:02:23.394220          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:02:23.670366          Launched VM: 67671728 pid: 4040 (0xfc8) frontend: headless name: boinc_bfaa30f0aac240b7
00:02:24.505793          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={Could not find a registered machine named 'boinc_c9c12581d2aaf214'}, preserve=false aResultDetail=0
00:02:24.967989          ERROR [COM]: aRC=VBOX_E_FILE_ERROR (0x80bb0004) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Could not find file for the medium 'C:\Program Files\BOINC\a\slots\10\vm_image.vdi' (VERR_FILE_NOT_FOUND)}, preserve=false aResultDetail=-102
00:02:25.419895          Saving settings file "C:\Program Files\BOINC\a\slots\10\boinc_c9c12581d2aaf214\boinc_c9c12581d2aaf214.vbox" with version "1.16-windows"
00:02:25.694139          Saving settings file "C:\Users\Administrator\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:02:26.224739          Saving settings file "C:\Program Files\BOINC\a\slots\10\boinc_c9c12581d2aaf214\boinc_c9c12581d2aaf214.vbox" with version "1.16-windows"
00:02:26.718994          Saving settings file "C:\Program Files\BOINC\a\slots\10\boinc_c9c12581d2aaf214\boinc_c9c12581d2aaf214.vbox" with version "1.16-windows"
00:02:27.240859          Saving settings file "C:\Program Files\BOINC\a\slots\10\boinc_c9c12581d2aaf214\boinc_c9c12581d2aaf214.vbox" with version "1.16-windows"
00:02:28.538307          Saving settings file "C:\Program Files\BOINC\a\slots\10\boinc_c9c12581d2aaf214\boinc_c9c12581d2aaf214.vbox" with version "1.16-windows"
00:02:29.524406          Saving settings file "C:\Program Files\BOINC\a\slots\13\boinc_bfaa30f0aac240b7\boinc_bfaa30f0aac240b7.vbox" with version "1.16-windows"
00:02:29.703314          Saving settings file "C:\Program Files\BOINC\a\slots\10\boinc_c9c12581d2aaf214\boinc_c9c12581d2aaf214.vbox" with version "1.16-windows"
00:02:30.072234          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:02:30.404287          Saving settings file "C:\Program Files\BOINC\a\slots\13\boinc_bfaa30f0aac240b7\boinc_bfaa30f0aac240b7.vbox" with version "1.16-windows"
00:02:30.612939          Saving settings file "C:\Program Files\BOINC\a\slots\10\boinc_c9c12581d2aaf214\boinc_c9c12581d2aaf214.vbox" with version "1.16-windows"
00:02:30.807980          Saving settings file "C:\Users\Administrator\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:02:31.146821          Saving settings file "C:\Program Files\BOINC\a\slots\10\boinc_c9c12581d2aaf214\boinc_c9c12581d2aaf214.vbox" with version "1.16-windows"
00:02:32.130581          Saving settings file "C:\Program Files\BOINC\a\slots\10\boinc_c9c12581d2aaf214\boinc_c9c12581d2aaf214.vbox" with version "1.16-windows"
00:02:32.401706          Saving settings file "C:\Program Files\BOINC\a\slots\10\boinc_c9c12581d2aaf214\boinc_c9c12581d2aaf214.vbox" with version "1.16-windows"
00:02:32.709273          Saving settings file "C:\Program Files\BOINC\a\slots\10\boinc_c9c12581d2aaf214\boinc_c9c12581d2aaf214.vbox" with version "1.16-windows"
00:02:33.002243          Saving settings file "C:\Program Files\BOINC\a\slots\10\boinc_c9c12581d2aaf214\boinc_c9c12581d2aaf214.vbox" with version "1.16-windows"
00:02:33.308655          Saving settings file "C:\Program Files\BOINC\a\slots\10\boinc_c9c12581d2aaf214\boinc_c9c12581d2aaf214.vbox" with version "1.16-windows"
00:02:34.101499          Saving settings file "C:\Program Files\BOINC\a\slots\10\boinc_c9c12581d2aaf214\boinc_c9c12581d2aaf214.vbox" with version "1.16-windows"
00:02:35.079971          Saving settings file "C:\Program Files\BOINC\a\slots\10\boinc_c9c12581d2aaf214\boinc_c9c12581d2aaf214.vbox" with version "1.16-windows"
00:02:35.626184          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:02:35.639549          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:02:35.639938          Saving settings file "C:\Users\Administrator\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:02:35.779357          Saving settings file "C:\Users\Administrator\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:02:35.918949          Saving settings file "C:\Program Files\BOINC\a\slots\10\boinc_c9c12581d2aaf214\boinc_c9c12581d2aaf214.vbox" with version "1.16-windows"
00:02:36.397654          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:02:36.398538          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:02:36.399116          Saving settings file "C:\Program Files\BOINC\a\slots\10\boinc_c9c12581d2aaf214\boinc_c9c12581d2aaf214.vbox" with version "1.16-windows"
00:02:36.934848          Saving settings file "C:\Program Files\BOINC\a\slots\10\boinc_c9c12581d2aaf214\boinc_c9c12581d2aaf214.vbox" with version "1.16-windows"
00:02:37.229641          Saving settings file "C:\Program Files\BOINC\a\slots\10\boinc_c9c12581d2aaf214\boinc_c9c12581d2aaf214.vbox" with version "1.16-windows"
00:02:37.762127          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:02:37.762343          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:02:37.770577          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:02:38.175932          Launched VM: 67710592 pid: 15436 (0x3c4c) frontend: headless name: boinc_c9c12581d2aaf214

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

irtio-scsi Port:   1
Maximum PIIX3 Floppy Controllers:1
Maximum ICH9 Floppy Controllers: 1
Maximum Floppy Port count:       1
Maximum Devices per Floppy Port: 2
Default machine folder:          C:\Users\Administrator\VirtualBox VMs
Raw-mode Supported:              no
Exclusive HW virtualization use: off
Default hard disk format:        VDI
VRDE auth library:               VBoxAuth
Webservice auth. library:        VBoxAuth
Remote desktop ExtPack:          
Log history count:               3
Default frontend:                
Default audio driver:            DirectSound
Autostart database path:         
Default Guest Additions ISO:     C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso
Logging Level:                   all
Proxy Mode:                      System
Proxy URL:                       

2020-08-08 02:56:01 (17148): 
Command: VBoxManage -q list hostinfo 
Exit Code: 0
Output:
Host Information:

Host time: 2020-08-07T18:56:01.029000000Z
Processor online count: 12
Processor count: 12
Processor online core count: 6
Processor core count: 6
Processor supports HW virtualization: no
Processor supports PAE: yes
Processor supports long mode: yes
Processor supports nested paging: no
Processor supports unrestricted guest: no
Processor supports nested HW virtualization: no
Processor#0 speed: unknown
Processor#0 description: AMD Ryzen 5 2600 Six-Core Processor
Processor#1 speed: unknown
Processor#1 description: AMD Ryzen 5 2600 Six-Core Processor
Processor#2 speed: unknown
Processor#2 description: AMD Ryzen 5 2600 Six-Core Processor
Processor#3 speed: unknown
Processor#3 description: AMD Ryzen 5 2600 Six-Core Processor
Processor#4 speed: unknown
Processor#4 description: AMD Ryzen 5 2600 Six-Core Processor
Processor#5 speed: unknown
Processor#5 description: AMD Ryzen 5 2600 Six-Core Processor
Processor#6 speed: unknown
Processor#6 description: AMD Ryzen 5 2600 Six-Core Processor
Processor#7 speed: unknown
Processor#7 description: AMD Ryzen 5 2600 Six-Core Processor
Processor#8 speed: unknown
Processor#8 description: AMD Ryzen 5 2600 Six-Core Processor
Processor#9 speed: unknown
Processor#9 description: AMD Ryzen 5 2600 Six-Core Processor
Processor#10 speed: unknown
Processor#10 description: AMD Ryzen 5 2600 Six-Core Processor
Processor#11 speed: unknown
Processor#11 description: AMD Ryzen 5 2600 Six-Core Processor
Memory size: 8143 MByte
Memory available: 3071 MByte
Operating system: Windows 10
Operating system version: 10.0.18363

2020-08-08 02:56:01 (17148): 
Command: VBoxManage -q showvminfo "boinc_bfaa30f0aac240b7" --machinereadable 
Exit Code: -2135228415
Output:
VBoxManage.exe: error: Could not find a registered machine named 'boinc_bfaa30f0aac240b7'
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown
VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2699 of file VBoxManageInfo.cpp

2020-08-08 02:56:02 (17148): 
Command: VBoxManage -q showhdinfo "C:\Program Files\BOINC\a\slots\13/vm_image.vdi" 
Exit Code: -2135228412
Output:
VBoxManage.exe: error: Could not find file for the medium 'C:\Program Files\BOINC\a\slots\13\vm_image.vdi' (VERR_FILE_NOT_FOUND)
VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp

2020-08-08 02:56:03 (17148): 
Command: VBoxManage -q createvm --name "boinc_bfaa30f0aac240b7" --basefolder "C:\Program Files\BOINC\a\slots\13" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_bfaa30f0aac240b7' is created and registered.
UUID: 839238c7-9153-4900-b839-90b09ee3b1a3
Settings file: 'C:\Program Files\BOINC\a\slots\13\boinc_bfaa30f0aac240b7\boinc_bfaa30f0aac240b7.vbox'

2020-08-08 02:56:03 (17148): 
Command: VBoxManage -q modifyvm "boinc_bfaa30f0aac240b7" --description "07879855_07_0" 
Exit Code: 0
Output:

2020-08-08 02:56:04 (17148): 
Command: VBoxManage -q modifyvm "boinc_bfaa30f0aac240b7" --memory 3072 
Exit Code: 0
Output:

2020-08-08 02:56:05 (17148): 
Command: VBoxManage -q modifyvm "boinc_bfaa30f0aac240b7" --cpus 1 
Exit Code: 0
Output:

2020-08-08 02:56:06 (17148): 
Command: VBoxManage -q modifyvm "boinc_bfaa30f0aac240b7" --acpi on --ioapic on 
Exit Code: 0
Output:

2020-08-08 02:56:07 (17148): 
Command: VBoxManage -q modifyvm "boinc_bfaa30f0aac240b7" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2020-08-08 02:56:08 (17148): 
Command: VBoxManage -q modifyvm "boinc_bfaa30f0aac240b7" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2020-08-08 02:56:09 (17148): 
Command: VBoxManage -q modifyvm "boinc_bfaa30f0aac240b7" --cableconnected1 on 
Exit Code: 0
Output:

2020-08-08 02:56:10 (17148): 
Command: VBoxManage -q modifyvm "boinc_bfaa30f0aac240b7" --usb off 
Exit Code: 0
Output:

2020-08-08 02:56:10 (17148): 
Command: VBoxManage -q modifyvm "boinc_bfaa30f0aac240b7" --uart1 off --uart2 off 
Exit Code: 0
Output:

2020-08-08 02:56:11 (17148): 
Command: VBoxManage -q modifyvm "boinc_bfaa30f0aac240b7" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2020-08-08 02:56:11 (17148): 
Command: VBoxManage -q modifyvm "boinc_bfaa30f0aac240b7" --audio none 
Exit Code: 0
Output:

2020-08-08 02:56:12 (17148): 
Command: VBoxManage -q modifyvm "boinc_bfaa30f0aac240b7" --clipboard disabled 
Exit Code: 0
Output:

2020-08-08 02:56:12 (17148): 
Command: VBoxManage -q modifyvm "boinc_bfaa30f0aac240b7" --draganddrop disabled 
Exit Code: 0
Output:

2020-08-08 02:56:13 (17148): 
Command: VBoxManage -q storagectl "boinc_bfaa30f0aac240b7" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2020-08-08 02:56:13 (17148): 
Command: VBoxManage -q storageattach "boinc_bfaa30f0aac240b7" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\Program Files\BOINC\a\slots\13/vm_isocontext.iso" 
Exit Code: 0
Output:

2020-08-08 02:56:14 (17148): 
Command: VBoxManage -q storageattach "boinc_bfaa30f0aac240b7" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2020-08-08 02:56:15 (17148): 
Command: VBoxManage -q bandwidthctl "boinc_bfaa30f0aac240b7" add "boinc_bfaa30f0aac240b7_net" --type network --limit 1024G 
Exit Code: 0
Output:

2020-08-08 02:56:15 (17148): 
Command: VBoxManage -q sharedfolder add "boinc_bfaa30f0aac240b7" --name "shared" --hostpath "C:\Program Files\BOINC\a\slots\13/shared"
Exit Code: 0
Output:

2020-08-08 02:56:21 (17148): 
Command: VBoxManage -q startvm "boinc_bfaa30f0aac240b7" --type headless
Exit Code: -2147467259
Output:
Waiting for VM "boinc_bfaa30f0aac240b7" to power on...
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: AMD-V is disabled in the BIOS (or by the host OS) (VERR_SVM_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole

2020-08-08 02:56:22 (17148): 
Command: VBoxManage -q snapshot "boinc_bfaa30f0aac240b7" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2020-08-08 02:56:22 (17148): 
Command: VBoxManage -q bandwidthctl "boinc_bfaa30f0aac240b7" remove "boinc_bfaa30f0aac240b7_net" 
Exit Code: 0
Output:

2020-08-08 02:56:23 (17148): 
Command: VBoxManage -q unregistervm "boinc_bfaa30f0aac240b7" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

2020-08-08 02:56:23 (17148): 
Command: VBoxManage -q closemedium dvd "C:\Program Files\BOINC\a\slots\13/vm_isocontext.iso" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

02:56:33 (17148): called boinc_finish(-2147467259)

</stderr_txt>
]]>


©2025 COPYRIGHT 2017-2018 NCN