Name | 07947651_41_1 |
Workunit | 7558310 |
Created | 21 Sep 2020, 15:09:58 UTC |
Sent | 21 Sep 2020, 15:15:04 UTC |
Report deadline | 26 Sep 2020, 15:15:04 UTC |
Received | 22 Sep 2020, 5:04:04 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | -2147467259 (0x80004005) Unknown error code |
Computer ID | 4434 |
Run time | 24 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 3.75 GFLOPS |
Application version | boinc2docker v1.14 (vbox64_mt) windows_x86_64 |
Peak working set size | 11.50 MB |
Peak swap size | 6.23 MB |
Peak disk usage | 501.19 MB |
<core_client_version>7.16.7</core_client_version> <![CDATA[ <message> Unbekannter Fehler (0x80004005) - exit code -2147467259 (0x80004005)</message> <stderr_txt> 2020-09-21 17:25:02 (9744): Detected: vboxwrapper 26202 2020-09-21 17:25:02 (9744): Detected: BOINC client v7.16.7 2020-09-21 17:25:04 (9744): Detected: VirtualBox VboxManage Interface (Version: 6.1.10) 2020-09-21 17:25:06 (9744): Create VM. (boinc_3137a4dcd63bfeea, slot#5) 2020-09-21 17:25:06 (9744): Updating drive controller type and model for desired configuration. 2020-09-21 17:25:08 (9744): Setting Memory Size for VM. (3072MB) 2020-09-21 17:25:09 (9744): Setting CPU Count for VM. (1) 2020-09-21 17:25:10 (9744): Setting Chipset Options for VM. 2020-09-21 17:25:11 (9744): Setting Boot Options for VM. 2020-09-21 17:25:11 (9744): Setting Network Configuration for NAT. 2020-09-21 17:25:12 (9744): Enabling VM Network Access. 2020-09-21 17:25:12 (9744): Disabling USB Support for VM. 2020-09-21 17:25:12 (9744): Disabling COM Port Support for VM. 2020-09-21 17:25:13 (9744): Disabling LPT Port Support for VM. 2020-09-21 17:25:14 (9744): Disabling Audio Support for VM. 2020-09-21 17:25:14 (9744): Disabling Clipboard Support for VM. 2020-09-21 17:25:15 (9744): Disabling Drag and Drop Support for VM. 2020-09-21 17:25:16 (9744): Adding storage controller(s) to VM. 2020-09-21 17:25:16 (9744): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso) 2020-09-21 17:25:17 (9744): Adding VirtualBox Guest Additions to VM. 2020-09-21 17:25:17 (9744): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2020-09-21 17:25:19 (9744): Enabling shared directory for VM. 2020-09-21 17:25:20 (9744): Starting VM using VBoxManage interface. (boinc_3137a4dcd63bfeea, slot#5) 2020-09-21 17:25:25 (9744): Error in start VM for VM: -2147467259 Command: VBoxManage -q startvm "boinc_3137a4dcd63bfeea" --type headless Output: Waiting for VM "boinc_3137a4dcd63bfeea" to power on... VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2020-09-21 17:25:25 (9744): VM failed to start. 2020-09-21 17:25:25 (9744): Could not start 2020-09-21 17:25:25 (9744): ERROR: VM failed to start 2020-09-21 17:25:25 (9744): Powering off VM. 2020-09-21 17:25:25 (9744): Deregistering VM. (boinc_3137a4dcd63bfeea, slot#5) 2020-09-21 17:25:26 (9744): Removing network bandwidth throttle group from VM. 2020-09-21 17:25:26 (9744): Removing VM from VirtualBox. 2020-09-21 17:25:27 (9744): Removing virtual ISO 9660 disk from VirtualBox. Hypervisor System Log: 00:00:00.482062 netIfIsWireless: CreateFile on '\\.\{B0941365-A98C-48D4-A417-D0EBAD80CD7C}' failed with rcWin=2 (0x2) - ignoring 00:00:00.484201 netIfIsWireless: CreateFile on '\\.\{1CB60883-D75E-4134-8C3F-1BB9E179F024}' failed with rcWin=2 (0x2) - ignoring 00:00:00.489659 HostDnsMonitor: initializing 00:00:00.499747 HostDnsMonitor: updating information 00:00:00.499778 HostDnsMonitor: old information 00:00:00.499780 no server entries 00:00:00.499781 no domain set 00:00:00.499782 no search string entries 00:00:00.499783 HostDnsMonitor: new information 00:00:00.499783 server 1: 192.168.2.1 00:00:00.499784 domain: Speedport_W_724V_09011603_06_006 00:00:00.499785 no search string entries 00:00:00.655220 SUPR0QueryVTCaps -> VERR_VMX_MSR_ALL_VMX_DISABLED 00:00:00.655778 VD: VDInit finished with VINF_SUCCESS 00:00:00.657076 VirtualBox: object created 00:00:02.266742 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={Could not find a registered machine named 'boinc_3137a4dcd63bfeea'}, preserve=false aResultDetail=0 00:00:03.058335 ERROR [COM]: aRC=VBOX_E_FILE_ERROR (0x80bb0004) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Could not find file for the medium 'H:\BOINC2\DaTa\slots\5\vm_image.vdi' (VERR_FILE_NOT_FOUND)}, preserve=false aResultDetail=-102 00:00:03.841458 Saving settings file "H:\BOINC2\DaTa\slots\5\boinc_3137a4dcd63bfeea\boinc_3137a4dcd63bfeea.vbox" with version "1.16-windows" 00:00:03.877517 Saving settings file "C:\Users\bonsai\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:04.457322 Saving settings file "H:\BOINC2\DaTa\slots\5\boinc_3137a4dcd63bfeea\boinc_3137a4dcd63bfeea.vbox" with version "1.16-windows" 00:00:05.569180 Saving settings file "H:\BOINC2\DaTa\slots\5\boinc_3137a4dcd63bfeea\boinc_3137a4dcd63bfeea.vbox" with version "1.16-windows" 00:00:06.498111 Saving settings file "H:\BOINC2\DaTa\slots\5\boinc_3137a4dcd63bfeea\boinc_3137a4dcd63bfeea.vbox" with version "1.16-windows" 00:00:07.193429 Saving settings file "H:\BOINC2\DaTa\slots\5\boinc_3137a4dcd63bfeea\boinc_3137a4dcd63bfeea.vbox" with version "1.16-windows" 00:00:08.113330 Saving settings file "H:\BOINC2\DaTa\slots\5\boinc_3137a4dcd63bfeea\boinc_3137a4dcd63bfeea.vbox" with version "1.16-windows" 00:00:08.538028 Saving settings file "H:\BOINC2\DaTa\slots\5\boinc_3137a4dcd63bfeea\boinc_3137a4dcd63bfeea.vbox" with version "1.16-windows" 00:00:09.212507 Saving settings file "H:\BOINC2\DaTa\slots\5\boinc_3137a4dcd63bfeea\boinc_3137a4dcd63bfeea.vbox" with version "1.16-windows" 00:00:09.614644 Saving settings file "H:\BOINC2\DaTa\slots\5\boinc_3137a4dcd63bfeea\boinc_3137a4dcd63bfeea.vbox" with version "1.16-windows" 00:00:10.045566 Saving settings file "H:\BOINC2\DaTa\slots\5\boinc_3137a4dcd63bfeea\boinc_3137a4dcd63bfeea.vbox" with version "1.16-windows" 00:00:10.675747 Saving settings file "H:\BOINC2\DaTa\slots\5\boinc_3137a4dcd63bfeea\boinc_3137a4dcd63bfeea.vbox" with version "1.16-windows" 00:00:11.341855 Saving settings file "H:\BOINC2\DaTa\slots\5\boinc_3137a4dcd63bfeea\boinc_3137a4dcd63bfeea.vbox" with version "1.16-windows" 00:00:11.962376 Saving settings file "H:\BOINC2\DaTa\slots\5\boinc_3137a4dcd63bfeea\boinc_3137a4dcd63bfeea.vbox" with version "1.16-windows" 00:00:12.363593 Saving settings file "H:\BOINC2\DaTa\slots\5\boinc_3137a4dcd63bfeea\boinc_3137a4dcd63bfeea.vbox" with version "1.16-windows" 00:00:13.046302 Saving settings file "H:\BOINC2\DaTa\slots\5\boinc_3137a4dcd63bfeea\boinc_3137a4dcd63bfeea.vbox" with version "1.16-windows" 00:00:13.716512 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:13.718481 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:13.718722 Saving settings file "C:\Users\bonsai\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:13.739670 Saving settings file "C:\Users\bonsai\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:13.744434 Saving settings file "H:\BOINC2\DaTa\slots\5\boinc_3137a4dcd63bfeea\boinc_3137a4dcd63bfeea.vbox" with version "1.16-windows" 00:00:14.360313 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:14.361904 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:14.362039 Saving settings file "C:\Users\bonsai\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:14.374705 Saving settings file "C:\Users\bonsai\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:14.379441 Saving settings file "H:\BOINC2\DaTa\slots\5\boinc_3137a4dcd63bfeea\boinc_3137a4dcd63bfeea.vbox" with version "1.16-windows" 00:00:15.210350 Saving settings file "H:\BOINC2\DaTa\slots\5\boinc_3137a4dcd63bfeea\boinc_3137a4dcd63bfeea.vbox" with version "1.16-windows" 00:00:16.195837 Saving settings file "H:\BOINC2\DaTa\slots\5\boinc_3137a4dcd63bfeea\boinc_3137a4dcd63bfeea.vbox" with version "1.16-windows" 00:00:16.928827 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:16.928996 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:16.939519 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:17.883540 Launched VM: 61851280 pid: 14264 (0x37b8) frontend: headless name: boinc_3137a4dcd63bfeea 00:00:22.456849 Saving settings file "H:\BOINC2\DaTa\slots\5\boinc_3137a4dcd63bfeea\boinc_3137a4dcd63bfeea.vbox" with version "1.16-windows" 00:00:22.869417 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:23.335263 Saving settings file "H:\BOINC2\DaTa\slots\5\boinc_3137a4dcd63bfeea\boinc_3137a4dcd63bfeea.vbox" with version "1.16-windows" 00:00:24.108986 Saving settings file "C:\Users\bonsai\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:29.871915 main VirtualBox: object deletion starts 00:00:29.872830 main HostDnsMonitor: shutting down ... 00:00:29.873336 main HostDnsMonitor: shut down 00:00:29.875479 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:29.875675 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: lers: 1 Maximum SAS ICH9 Controllers: 8 Maximum SAS Port count: 255 Maximum Devices per SAS Port: 1 Maximum NVMe PIIX3 Controllers: 1 Maximum NVMe ICH9 Controllers: 8 Maximum NVMe Port count: 255 Maximum Devices per NVMe Port: 1 Maximum virtio-scsi PIIX3 Controllers: 1 Maximum virtio-scsi ICH9 Controllers: 8 Maximum virtio-scsi Port count: 256 Maximum Devices per virtio-scsi Port: 1 Maximum PIIX3 Floppy Controllers:1 Maximum ICH9 Floppy Controllers: 1 Maximum Floppy Port count: 1 Maximum Devices per Floppy Port: 2 Default machine folder: C:\Users\bonsai\VirtualBox VMs Raw-mode Supported: no Exclusive HW virtualization use: off Default hard disk format: VDI VRDE auth library: VBoxAuth Webservice auth. library: VBoxAuth Remote desktop ExtPack: Log history count: 3 Default frontend: Default audio driver: DirectSound Autostart database path: Default Guest Additions ISO: C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso Logging Level: all Proxy Mode: System Proxy URL: 2020-09-21 17:25:05 (9744): Command: VBoxManage -q list hostinfo Exit Code: 0 Output: Host Information: Host time: 2020-09-21T15:25:04.842000000Z Processor online count: 8 Processor count: 8 Processor online core count: 4 Processor core count: 4 Processor supports HW virtualization: no Processor supports PAE: yes Processor supports long mode: yes Processor supports nested paging: no Processor supports unrestricted guest: no Processor supports nested HW virtualization: no Processor#0 speed: unknown Processor#0 description: Intel(R) Xeon(R) CPU E3-1231 v3 @ 3.40GHz Processor#1 speed: unknown Processor#1 description: Intel(R) Xeon(R) CPU E3-1231 v3 @ 3.40GHz Processor#2 speed: unknown Processor#2 description: Intel(R) Xeon(R) CPU E3-1231 v3 @ 3.40GHz Processor#3 speed: unknown Processor#3 description: Intel(R) Xeon(R) CPU E3-1231 v3 @ 3.40GHz Processor#4 speed: unknown Processor#4 description: Intel(R) Xeon(R) CPU E3-1231 v3 @ 3.40GHz Processor#5 speed: unknown Processor#5 description: Intel(R) Xeon(R) CPU E3-1231 v3 @ 3.40GHz Processor#6 speed: unknown Processor#6 description: Intel(R) Xeon(R) CPU E3-1231 v3 @ 3.40GHz Processor#7 speed: unknown Processor#7 description: Intel(R) Xeon(R) CPU E3-1231 v3 @ 3.40GHz Memory size: 16325 MByte Memory available: 9363 MByte Operating system: Windows 10 Operating system version: 10.0.19041 2020-09-21 17:25:05 (9744): Command: VBoxManage -q showvminfo "boinc_3137a4dcd63bfeea" --machinereadable Exit Code: -2135228415 Output: VBoxManage.exe: error: Could not find a registered machine named 'boinc_3137a4dcd63bfeea' VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2699 of file VBoxManageInfo.cpp 2020-09-21 17:25:06 (9744): Command: VBoxManage -q showhdinfo "H:\BOINC2\DaTa\slots\5/vm_image.vdi" Exit Code: -2135228412 Output: VBoxManage.exe: error: Could not find file for the medium 'H:\BOINC2\DaTa\slots\5\vm_image.vdi' (VERR_FILE_NOT_FOUND) VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp 2020-09-21 17:25:07 (9744): Command: VBoxManage -q createvm --name "boinc_3137a4dcd63bfeea" --basefolder "H:\BOINC2\DaTa\slots\5" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_3137a4dcd63bfeea' is created and registered. UUID: ce5976d4-2df3-478c-977f-99578477e7e3 Settings file: 'H:\BOINC2\DaTa\slots\5\boinc_3137a4dcd63bfeea\boinc_3137a4dcd63bfeea.vbox' 2020-09-21 17:25:08 (9744): Command: VBoxManage -q modifyvm "boinc_3137a4dcd63bfeea" --description "07947651_41_1" Exit Code: 0 Output: 2020-09-21 17:25:09 (9744): Command: VBoxManage -q modifyvm "boinc_3137a4dcd63bfeea" --memory 3072 Exit Code: 0 Output: 2020-09-21 17:25:10 (9744): Command: VBoxManage -q modifyvm "boinc_3137a4dcd63bfeea" --cpus 1 Exit Code: 0 Output: 2020-09-21 17:25:11 (9744): Command: VBoxManage -q modifyvm "boinc_3137a4dcd63bfeea" --acpi on --ioapic on Exit Code: 0 Output: 2020-09-21 17:25:11 (9744): Command: VBoxManage -q modifyvm "boinc_3137a4dcd63bfeea" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2020-09-21 17:25:12 (9744): Command: VBoxManage -q modifyvm "boinc_3137a4dcd63bfeea" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2020-09-21 17:25:12 (9744): Command: VBoxManage -q modifyvm "boinc_3137a4dcd63bfeea" --cableconnected1 on Exit Code: 0 Output: 2020-09-21 17:25:12 (9744): Command: VBoxManage -q modifyvm "boinc_3137a4dcd63bfeea" --usb off Exit Code: 0 Output: 2020-09-21 17:25:13 (9744): Command: VBoxManage -q modifyvm "boinc_3137a4dcd63bfeea" --uart1 off --uart2 off Exit Code: 0 Output: 2020-09-21 17:25:14 (9744): Command: VBoxManage -q modifyvm "boinc_3137a4dcd63bfeea" --lpt1 off --lpt2 off Exit Code: 0 Output: 2020-09-21 17:25:14 (9744): Command: VBoxManage -q modifyvm "boinc_3137a4dcd63bfeea" --audio none Exit Code: 0 Output: 2020-09-21 17:25:15 (9744): Command: VBoxManage -q modifyvm "boinc_3137a4dcd63bfeea" --clipboard disabled Exit Code: 0 Output: 2020-09-21 17:25:16 (9744): Command: VBoxManage -q modifyvm "boinc_3137a4dcd63bfeea" --draganddrop disabled Exit Code: 0 Output: 2020-09-21 17:25:16 (9744): Command: VBoxManage -q storagectl "boinc_3137a4dcd63bfeea" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2020-09-21 17:25:17 (9744): Command: VBoxManage -q storageattach "boinc_3137a4dcd63bfeea" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "H:\BOINC2\DaTa\slots\5/vm_isocontext.iso" Exit Code: 0 Output: 2020-09-21 17:25:17 (9744): Command: VBoxManage -q storageattach "boinc_3137a4dcd63bfeea" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2020-09-21 17:25:19 (9744): Command: VBoxManage -q bandwidthctl "boinc_3137a4dcd63bfeea" add "boinc_3137a4dcd63bfeea_net" --type network --limit 1024G Exit Code: 0 Output: 2020-09-21 17:25:19 (9744): Command: VBoxManage -q sharedfolder add "boinc_3137a4dcd63bfeea" --name "shared" --hostpath "H:\BOINC2\DaTa\slots\5/shared" Exit Code: 0 Output: 2020-09-21 17:25:25 (9744): Command: VBoxManage -q startvm "boinc_3137a4dcd63bfeea" --type headless Exit Code: -2147467259 Output: Waiting for VM "boinc_3137a4dcd63bfeea" to power on... VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2020-09-21 17:25:26 (9744): Command: VBoxManage -q snapshot "boinc_3137a4dcd63bfeea" list Exit Code: -108 Output: This machine does not have any snapshots 2020-09-21 17:25:26 (9744): Command: VBoxManage -q bandwidthctl "boinc_3137a4dcd63bfeea" remove "boinc_3137a4dcd63bfeea_net" Exit Code: 0 Output: 2020-09-21 17:25:27 (9744): Command: VBoxManage -q unregistervm "boinc_3137a4dcd63bfeea" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 2020-09-21 17:25:28 (9744): Command: VBoxManage -q closemedium dvd "H:\BOINC2\DaTa\slots\5/vm_isocontext.iso" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 17:25:33 (9744): called boinc_finish(-2147467259) </stderr_txt> ]]>
©2024 COPYRIGHT 2017-2018 NCN