Name | 07952526_37_0 |
Workunit | 7625613 |
Created | 22 Sep 2020, 18:46:06 UTC |
Sent | 23 Sep 2020, 2:38:02 UTC |
Report deadline | 28 Sep 2020, 2:38:02 UTC |
Received | 21 Jul 2021, 2:26:45 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | 1 (0x00000001) Unknown error code |
Computer ID | 8927 |
Run time | 35 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 4.62 GFLOPS |
Application version | boinc2docker v1.14 (vbox64_mt) windows_x86_64 |
Peak working set size | 9.98 MB |
Peak swap size | 6.22 MB |
Peak disk usage | 498.94 MB |
<core_client_version>7.14.3</core_client_version> <![CDATA[ <message> Incorrect function. (0x1) - exit code 1 (0x1)</message> <stderr_txt> 2020-09-23 14:06:11 (20736): Detected: vboxwrapper 26202 2020-09-23 14:06:11 (20736): Detected: BOINC client v7.16.11 2020-09-23 14:06:11 (20736): Detected: VirtualBox VboxManage Interface (Version: 6.0.22) 2020-09-23 14:06:11 (20736): CreateProcess failed! (299). 2020-09-23 14:06:13 (20736): Create VM. (boinc_8e1af2468150bc0f, slot#42) 2020-09-23 14:06:13 (20736): Updating drive controller type and model for desired configuration. 2020-09-23 14:06:14 (20736): Setting Memory Size for VM. (3072MB) 2020-09-23 14:06:15 (20736): Setting CPU Count for VM. (1) 2020-09-23 14:06:15 (20736): Setting Chipset Options for VM. 2020-09-23 14:06:15 (20736): Setting Boot Options for VM. 2020-09-23 14:06:15 (20736): CreateProcess failed! (299). 2020-09-23 14:06:17 (20736): Setting Network Configuration for NAT. 2020-09-23 14:06:17 (20736): CreateProcess failed! (299). 2020-09-23 14:06:18 (20736): CreateProcess failed! (299). 2020-09-23 14:06:20 (20736): Enabling VM Network Access. 2020-09-23 14:06:20 (20736): Disabling USB Support for VM. 2020-09-23 14:06:21 (20736): Disabling COM Port Support for VM. 2020-09-23 14:06:21 (20736): Disabling LPT Port Support for VM. 2020-09-23 14:06:21 (20736): CreateProcess failed! (299). 2020-09-23 14:06:21 (20736): Disabling Audio Support for VM. 2020-09-23 14:06:21 (20736): CreateProcess failed! (299). 2020-09-23 14:06:21 (20736): Disabling Clipboard Support for VM. 2020-09-23 14:06:21 (20736): CreateProcess failed! (299). 2020-09-23 14:06:21 (20736): Disabling Drag and Drop Support for VM. 2020-09-23 14:06:21 (20736): CreateProcess failed! (299). 2020-09-23 14:06:21 (20736): Adding storage controller(s) to VM. 2020-09-23 14:06:21 (20736): CreateProcess failed! (299). 2020-09-23 14:06:23 (20736): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso) 2020-09-23 14:06:24 (20736): Adding VirtualBox Guest Additions to VM. 2020-09-23 14:06:29 (20736): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2020-09-23 14:06:29 (20736): CreateProcess failed! (299). 2020-09-23 14:06:30 (20736): CreateProcess failed! (299). 2020-09-23 14:06:31 (20736): CreateProcess failed! (299). 2020-09-23 14:06:32 (20736): Enabling shared directory for VM. 2020-09-23 14:06:33 (20736): Starting VM using VBoxManage interface. (boinc_8e1af2468150bc0f, slot#42) 2020-09-23 14:06:34 (20736): Error in start VM for VM: 1 Command: VBoxManage -q startvm "boinc_8e1af2468150bc0f" --type headless Output: Waiting for VM "boinc_8e1af2468150bc0f" to power on... VBoxManage.exe: error: The virtual machine 'boinc_8e1af2468150bc0f' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'D:\ProgramData\BOINC\slots\42\boinc_8e1af2468150bc0f\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine 2020-09-23 14:06:34 (20736): VM failed to start. 2020-09-23 14:06:34 (20736): Could not start 2020-09-23 14:06:34 (20736): ERROR: VM failed to start 2020-09-23 14:06:34 (20736): Powering off VM. 2020-09-23 14:06:34 (20736): Deregistering VM. (boinc_8e1af2468150bc0f, slot#42) 2020-09-23 14:06:34 (20736): CreateProcess failed! (299). 2020-09-23 14:06:34 (20736): Removing network bandwidth throttle group from VM. 2020-09-23 14:06:34 (20736): CreateProcess failed! (299). 2020-09-23 14:06:34 (20736): Removing VM from VirtualBox. 2020-09-23 14:06:34 (20736): CreateProcess failed! (299). 2020-09-23 14:06:34 (20736): Removing virtual ISO 9660 disk from VirtualBox. Hypervisor System Log: 00:02:52.118449 Saving settings file "D:\ProgramData\BOINC\slots\42\boinc_8859dab7a68c4bb3\boinc_8859dab7a68c4bb3.vbox" with version "1.16-windows" 00:02:53.251382 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:02:53.254851 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:02:53.325620 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:02:54.441089 AssertLogRel F:\tinderbox\win-6.0\src\VBox\Runtime\win\RTErrConvertFromWin32.cpp(448) int __cdecl RTErrConvertFromWin32(unsigned int): <NULL> 00:02:54.445211 Unhandled error 299 00:02:54.449717 ERROR [COM]: aRC=VBOX_E_IPRT_ERROR (0x80bb0005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={MachineWrap} aText={Could not launch a process for the machine 'boinc_8859dab7a68c4bb3' (VERR_UNRESOLVED_ERROR)}, preserve=false aResultDetail=-35 00:02:56.694655 Saving settings file "C:\Users\Colin\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:03:16.873037 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={Could not find a registered machine named 'boinc_8e1af2468150bc0f'}, preserve=false aResultDetail=0 00:03:17.143473 ERROR [COM]: aRC=VBOX_E_FILE_ERROR (0x80bb0004) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Could not find file for the medium 'D:\ProgramData\BOINC\slots\42\vm_image.vdi' (VERR_FILE_NOT_FOUND)}, preserve=false aResultDetail=-102 00:03:17.452887 Saving settings file "D:\ProgramData\BOINC\slots\42\boinc_8e1af2468150bc0f\boinc_8e1af2468150bc0f.vbox" with version "1.16-windows" 00:03:18.021634 Saving settings file "C:\Users\Colin\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:03:18.335989 Saving settings file "D:\ProgramData\BOINC\slots\42\boinc_8e1af2468150bc0f\boinc_8e1af2468150bc0f.vbox" with version "1.16-windows" 00:03:18.526153 Saving settings file "D:\ProgramData\BOINC\slots\42\boinc_8e1af2468150bc0f\boinc_8e1af2468150bc0f.vbox" with version "1.16-windows" 00:03:18.790169 Saving settings file "D:\ProgramData\BOINC\slots\42\boinc_8e1af2468150bc0f\boinc_8e1af2468150bc0f.vbox" with version "1.16-windows" 00:03:19.080977 Saving settings file "D:\ProgramData\BOINC\slots\42\boinc_8e1af2468150bc0f\boinc_8e1af2468150bc0f.vbox" with version "1.16-windows" 00:03:20.543100 Saving settings file "D:\ProgramData\BOINC\slots\42\boinc_8e1af2468150bc0f\boinc_8e1af2468150bc0f.vbox" with version "1.16-windows" 00:03:23.626291 Saving settings file "D:\ProgramData\BOINC\slots\42\boinc_8e1af2468150bc0f\boinc_8e1af2468150bc0f.vbox" with version "1.16-windows" 00:03:24.022114 Saving settings file "D:\ProgramData\BOINC\slots\42\boinc_8e1af2468150bc0f\boinc_8e1af2468150bc0f.vbox" with version "1.16-windows" 00:03:24.529754 Saving settings file "D:\ProgramData\BOINC\slots\42\boinc_8e1af2468150bc0f\boinc_8e1af2468150bc0f.vbox" with version "1.16-windows" 00:03:24.734261 Saving settings file "D:\ProgramData\BOINC\slots\42\boinc_8e1af2468150bc0f\boinc_8e1af2468150bc0f.vbox" with version "1.16-windows" 00:03:26.557687 Saving settings file "D:\ProgramData\BOINC\slots\42\boinc_8e1af2468150bc0f\boinc_8e1af2468150bc0f.vbox" with version "1.16-windows" 00:03:27.797493 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:03:27.920734 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:03:27.926718 Saving settings file "C:\Users\Colin\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:03:27.971588 Saving settings file "C:\Users\Colin\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:03:27.989065 Saving settings file "D:\ProgramData\BOINC\slots\42\boinc_8e1af2468150bc0f\boinc_8e1af2468150bc0f.vbox" with version "1.16-windows" 00:03:32.959759 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:03:32.966476 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:03:32.980295 Saving settings file "D:\ProgramData\BOINC\slots\42\boinc_8e1af2468150bc0f\boinc_8e1af2468150bc0f.vbox" with version "1.16-windows" 00:03:36.361399 Saving settings file "D:\ProgramData\BOINC\slots\42\boinc_8e1af2468150bc0f\boinc_8e1af2468150bc0f.vbox" with version "1.16-windows" 00:03:36.554689 Saving settings file "D:\ProgramData\BOINC\slots\42\boinc_8e1af2468150bc0f\boinc_8e1af2468150bc0f.vbox" with version "1.16-windows" 00:03:36.835911 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:03:36.837165 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:03:36.850660 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:03:37.817043 Watcher ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={MachineWrap} aText={The virtual machine 'boinc_8e1af2468150bc0f' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'D:\ProgramData\BOINC\slots\42\boinc_8e1af2468150bc0f\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0 00:03:37.820329 Watcher Reaper: Pid 13124 (3344) exited normally: 1 (0x1) 00:03:38.315592 ERROR [COM]: aRC=VBOX_E_OBJECT_IN_USE (0x80bb000c) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Cannot delete storage: medium 'D:\ProgramData\BOINC\slots\42\vm_isocontext.iso' is still attached to the following 1 virtual machine(s): 9f758214-3501-487a-a278-eed970511529}, preserve=false aResultDetail=0 00:03:38.345676 ERROR [COM]: aRC=VBOX_E_INVALID_OBJECT_STATE (0x80bb0007) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Storage for the medium 'D:\ProgramData\BOINC\slots\42\vm_isocontext.iso' is already created}, preserve=false aResultDetail=0 00:03:38.383532 ERROR [COM]: aRC=VBOX_E_OBJECT_IN_USE (0x80bb000c) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Medium 'D:\ProgramData\BOINC\slots\42\vm_isocontext.iso' cannot be closed because it is still attached to 1 virtual machines}, preserve=false aResultDetail=0 VM Execution Log: VM Startup Log: VM Trace Log: af2468150bc0f" --machinereadable Exit Code: -2135228415 Output: VBoxManage.exe: error: Could not find a registered machine named 'boinc_8e1af2468150bc0f' VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2664 of file VBoxManageInfo.cpp 2020-09-23 14:06:13 (20736): Command: VBoxManage -q showhdinfo "D:\ProgramData\BOINC\slots\42/vm_image.vdi" Exit Code: -2135228412 Output: VBoxManage.exe: error: Could not find file for the medium 'D:\ProgramData\BOINC\slots\42\vm_image.vdi' (VERR_FILE_NOT_FOUND) VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp 2020-09-23 14:06:14 (20736): Command: VBoxManage -q createvm --name "boinc_8e1af2468150bc0f" --basefolder "D:\ProgramData\BOINC\slots\42" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_8e1af2468150bc0f' is created and registered. UUID: 9f758214-3501-487a-a278-eed970511529 Settings file: 'D:\ProgramData\BOINC\slots\42\boinc_8e1af2468150bc0f\boinc_8e1af2468150bc0f.vbox' 2020-09-23 14:06:14 (20736): Command: VBoxManage -q modifyvm "boinc_8e1af2468150bc0f" --description "07952526_37_0" Exit Code: 0 Output: 2020-09-23 14:06:15 (20736): Command: VBoxManage -q modifyvm "boinc_8e1af2468150bc0f" --memory 3072 Exit Code: 0 Output: 2020-09-23 14:06:15 (20736): Command: VBoxManage -q modifyvm "boinc_8e1af2468150bc0f" --cpus 1 Exit Code: 0 Output: 2020-09-23 14:06:15 (20736): Command: VBoxManage -q modifyvm "boinc_8e1af2468150bc0f" --acpi on --ioapic on Exit Code: 0 Output: 2020-09-23 14:06:15 (20736): Command: VBoxManage -q modifyvm "boinc_8e1af2468150bc0f" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: -108 Output: 2020-09-23 14:06:17 (20736): Command: VBoxManage -q modifyvm "boinc_8e1af2468150bc0f" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2020-09-23 14:06:17 (20736): Command: VBoxManage -q modifyvm "boinc_8e1af2468150bc0f" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: -108 Output: 2020-09-23 14:06:18 (20736): Command: VBoxManage -q modifyvm "boinc_8e1af2468150bc0f" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: -108 Output: 2020-09-23 14:06:20 (20736): Command: VBoxManage -q modifyvm "boinc_8e1af2468150bc0f" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2020-09-23 14:06:20 (20736): Command: VBoxManage -q modifyvm "boinc_8e1af2468150bc0f" --cableconnected1 on Exit Code: 0 Output: 2020-09-23 14:06:20 (20736): Command: VBoxManage -q modifyvm "boinc_8e1af2468150bc0f" --usb off Exit Code: 0 Output: 2020-09-23 14:06:21 (20736): Command: VBoxManage -q modifyvm "boinc_8e1af2468150bc0f" --uart1 off --uart2 off Exit Code: 0 Output: 2020-09-23 14:06:21 (20736): Command: VBoxManage -q modifyvm "boinc_8e1af2468150bc0f" --lpt1 off --lpt2 off Exit Code: -108 Output: 2020-09-23 14:06:21 (20736): Command: VBoxManage -q modifyvm "boinc_8e1af2468150bc0f" --audio none Exit Code: -108 Output: 2020-09-23 14:06:21 (20736): Command: VBoxManage -q modifyvm "boinc_8e1af2468150bc0f" --clipboard disabled Exit Code: -108 Output: 2020-09-23 14:06:21 (20736): Command: VBoxManage -q modifyvm "boinc_8e1af2468150bc0f" --draganddrop disabled Exit Code: -108 Output: 2020-09-23 14:06:21 (20736): Command: VBoxManage -q storagectl "boinc_8e1af2468150bc0f" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: -108 Output: 2020-09-23 14:06:23 (20736): Command: VBoxManage -q storagectl "boinc_8e1af2468150bc0f" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2020-09-23 14:06:24 (20736): Command: VBoxManage -q storageattach "boinc_8e1af2468150bc0f" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "D:\ProgramData\BOINC\slots\42/vm_isocontext.iso" Exit Code: 0 Output: 2020-09-23 14:06:28 (20736): Command: VBoxManage -q storageattach "boinc_8e1af2468150bc0f" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "D:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: -2147024882 Output: VBoxManage.exe: error: Failed to create the VirtualBox object! VBoxManage.exe: error: Completely failed to instantiate CLSID_VirtualBox: E_OUTOFMEMORY VBoxManage.exe: error: Details: code E_OUTOFMEMORY (0x8007000e), component VirtualBoxClientWrap, interface IVirtualBoxClient 2020-09-23 14:06:29 (20736): Command: VBoxManage -q storageattach "boinc_8e1af2468150bc0f" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "D:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2020-09-23 14:06:29 (20736): Command: VBoxManage -q bandwidthctl "boinc_8e1af2468150bc0f" add "boinc_8e1af2468150bc0f_net" --type network --limit 1024G Exit Code: -108 Output: 2020-09-23 14:06:30 (20736): Command: VBoxManage -q bandwidthctl "boinc_8e1af2468150bc0f" add "boinc_8e1af2468150bc0f_net" --type network --limit 1024G Exit Code: -108 Output: 2020-09-23 14:06:31 (20736): Command: VBoxManage -q bandwidthctl "boinc_8e1af2468150bc0f" add "boinc_8e1af2468150bc0f_net" --type network --limit 1024G Exit Code: -108 Output: 2020-09-23 14:06:32 (20736): Command: VBoxManage -q bandwidthctl "boinc_8e1af2468150bc0f" add "boinc_8e1af2468150bc0f_net" --type network --limit 1024G Exit Code: 0 Output: 2020-09-23 14:06:33 (20736): Command: VBoxManage -q sharedfolder add "boinc_8e1af2468150bc0f" --name "shared" --hostpath "D:\ProgramData\BOINC\slots\42/shared" Exit Code: 0 Output: 2020-09-23 14:06:34 (20736): Command: VBoxManage -q startvm "boinc_8e1af2468150bc0f" --type headless Exit Code: 1 Output: Waiting for VM "boinc_8e1af2468150bc0f" to power on... VBoxManage.exe: error: The virtual machine 'boinc_8e1af2468150bc0f' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'D:\ProgramData\BOINC\slots\42\boinc_8e1af2468150bc0f\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine 2020-09-23 14:06:34 (20736): Command: VBoxManage -q snapshot "boinc_8e1af2468150bc0f" list Exit Code: -108 Output: 2020-09-23 14:06:34 (20736): Command: VBoxManage -q bandwidthctl "boinc_8e1af2468150bc0f" remove "boinc_8e1af2468150bc0f_net" Exit Code: -108 Output: 2020-09-23 14:06:34 (20736): Command: VBoxManage -q unregistervm "boinc_8e1af2468150bc0f" --delete Exit Code: -108 Output: 2020-09-23 14:06:34 (20736): Command: VBoxManage -q closemedium dvd "D:\ProgramData\BOINC\slots\42/vm_isocontext.iso" --delete Exit Code: -2135228404 Output: VBoxManage.exe: error: Cannot delete storage: medium 'D:\ProgramData\BOINC\slots\42\vm_isocontext.iso' is still attached to the following 1 virtual machine(s): 9f758214-3501-487a-a278-eed970511529 VBoxManage.exe: error: Details: code VBOX_E_OBJECT_IN_USE (0x80bb000c), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "DeleteStorage(pProgress.asOutParam())" at line 1679 of file VBoxManageDisk.cpp VBoxManage.exe: error: Failed to delete medium. Error code Unknown Status -2135228404 (0x80bb000c) VBoxManage.exe: error: Medium 'D:\ProgramData\BOINC\slots\42\vm_isocontext.iso' cannot be closed because it is still attached to 1 virtual machines VBoxManage.exe: error: Details: code VBOX_E_OBJECT_IN_USE (0x80bb000c), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "Close()" at line 1688 of file VBoxManageDisk.cpp 14:06:44 (20736): called boinc_finish(1) </stderr_txt> ]]>
©2024 COPYRIGHT 2017-2018 NCN