Task 9650620

Name 07953510_47_0
Workunit 7634339
Created 23 Sep 2020, 4:29:54 UTC
Sent 23 Sep 2020, 13:24:07 UTC
Report deadline 28 Sep 2020, 13:24:07 UTC
Received 24 Sep 2020, 13:51:22 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status 1 (0x00000001) Unknown error code
Computer ID 6729
Run time 15 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 4.31 GFLOPS
Application version boinc2docker v1.14 (vbox64_mt)
x86_64-apple-darwin
Peak working set size 6.92 MB
Peak swap size 4.11 GB
Peak disk usage 499.01 MB

Stderr output

<core_client_version>7.16.11</core_client_version>
<![CDATA[
<message>
process exited with code 1 (0x1, -255)</message>
<stderr_txt>
2020-09-23 09:26:06 (77328): vboxwrapper (7.7.26199): starting
2020-09-23 09:26:10 (77328): Feature: Checkpoint interval offset (363 seconds)
2020-09-23 09:26:10 (77328): Detected: VirtualBox VboxManage Interface (Version: 6.1.4)
2020-09-23 09:26:10 (77328): Detected: Sandbox Configuration Enabled
2020-09-23 09:26:10 (77328): Detected: Minimum checkpoint interval (600.000000 seconds)
2020-09-23 09:26:11 (77328): Create VM. (boinc_1d0f71eb87940538, slot#4)
2020-09-23 09:26:11 (77328): Updating drive controller type and model for desired configuration.
2020-09-23 09:26:11 (77328): Setting Memory Size for VM. (3072MB)
2020-09-23 09:26:11 (77328): Setting CPU Count for VM. (1)
2020-09-23 09:26:11 (77328): Setting Chipset Options for VM.
2020-09-23 09:26:11 (77328): Setting Boot Options for VM.
2020-09-23 09:26:11 (77328): Setting Network Configuration for NAT.
2020-09-23 09:26:11 (77328): Enabling VM Network Access.
2020-09-23 09:26:11 (77328): Disabling USB Support for VM.
2020-09-23 09:26:11 (77328): Disabling COM Port Support for VM.
2020-09-23 09:26:11 (77328): Disabling Audio Support for VM.
2020-09-23 09:26:11 (77328): Disabling Clipboard Support for VM.
2020-09-23 09:26:11 (77328): Disabling Drag and Drop Support for VM.
2020-09-23 09:26:11 (77328): Adding storage controller(s) to VM.
2020-09-23 09:26:12 (77328): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso)
2020-09-23 09:26:12 (77328): Adding VirtualBox Guest Additions to VM.
2020-09-23 09:26:13 (77328): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2020-09-23 09:26:13 (77328): Enabling shared directory for VM.
2020-09-23 09:26:13 (77328): Starting VM. (boinc_1d0f71eb87940538, slot#4)
2020-09-23 09:26:14 (77328): Error in start VM for VM: 1
Command:
VBoxManage -q startvm "boinc_1d0f71eb87940538" --type headless
Output:
VBoxManage: error: The virtual machine 'boinc_1d0f71eb87940538' has terminated unexpectedly during startup with exit code 1 (0x1)
VBoxManage: error: Details: code NS_ERROR_FAILURE (0x80004005), component MachineWrap, interface IMachine
Waiting for VM "boinc_1d0f71eb87940538" to power on...

2020-09-23 09:26:14 (77328): VM failed to start.
2020-09-23 09:26:14 (77328): Powering off VM.
2020-09-23 09:26:14 (77328): Deregistering VM. (boinc_1d0f71eb87940538, slot#4)
2020-09-23 09:26:14 (77328): Removing network bandwidth throttle group from VM.
2020-09-23 09:26:14 (77328): Removing storage controller(s) from VM.
2020-09-23 09:26:14 (77328): Removing VM from VirtualBox.
2020-09-23 09:26:14 (77328): Removing virtual ISO 9660 disk from VirtualBox.

    Hypervisor System Log:

00:00:03.158814 nspr-3   ERROR [COM]: aRC=NS_ERROR_INVALID_ARG (0x80070057) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={Cannot register the DVD image '/Applications/VirtualBox.app/Contents/MacOS/VBoxGuestAdditions.iso' {2dae15b7-9966-4a1e-9fda-1e45fcecc4c0} because a CD/DVD image '/Applications/VirtualBox.app/Contents/MacOS/VBoxGuestAdditions.iso' with UUID {3bb21af5-a790-46ab-91b3-8d7d68d94a85} already exists}, preserve=false aResultDetail=0
00:00:03.159096 nspr-2   ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:03.159493 nspr-5   Saving settings file "/Library/Application Support/BOINC Data/projects/virtualbox/VirtualBox.xml" with version "1.12-macosx"
00:00:03.160898 nspr-2   Saving settings file "/Library/Application Support/BOINC Data/projects/virtualbox/VirtualBox.xml" with version "1.12-macosx"
00:00:03.162344 nspr-4   Saving settings file "/Library/Application Support/BOINC Data/slots/3/boinc_190be1c2cde0e3f8/boinc_190be1c2cde0e3f8.vbox" with version "1.16-macosx"
00:00:03.208576 nspr-4   Saving settings file "/Library/Application Support/BOINC Data/slots/3/boinc_190be1c2cde0e3f8/boinc_190be1c2cde0e3f8.vbox" with version "1.16-macosx"
00:00:03.255044 nspr-4   Saving settings file "/Library/Application Support/BOINC Data/slots/3/boinc_190be1c2cde0e3f8/boinc_190be1c2cde0e3f8.vbox" with version "1.16-macosx"
00:00:03.337013 nspr-4   ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:03.337372 nspr-5   ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:03.350847 nspr-5   WARNING [COM]: aRC=NS_ERROR_FAILURE (0x80004005) aIID={16ced992-5fdc-4aba-aff5-6a39bbd7c38b} aComponent={HostWrap} aText={Could not load the Host USB Proxy service: VERR_GENERAL_FAILURE}, preserve=true  aResultDetail=0
00:00:03.351117 nspr-4   WARNING [COM]: aRC=NS_ERROR_FAILURE (0x80004005) aIID={16ced992-5fdc-4aba-aff5-6a39bbd7c38b} aComponent={HostWrap} aText={Could not load the Host USB Proxy service: VERR_GENERAL_FAILURE}, preserve=true  aResultDetail=0
00:00:03.356222 nspr-5   ERROR [COM]: aRC=NS_ERROR_FAILURE (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:03.417296 nspr-3   Launched VM: 1015043344 pid: 77428 (0x12e74) frontend: headless name: boinc_190be1c2cde0e3f8
00:00:03.919796 Watcher  ERROR [COM]: aRC=NS_ERROR_FAILURE (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The virtual machine 'boinc_190be1c2cde0e3f8' has terminated unexpectedly during startup with exit code 1 (0x1)}, preserve=false aResultDetail=0
00:00:03.963301 nspr-5   ERROR [COM]: aRC=NS_ERROR_FAILURE (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:04.009707 nspr-5   Saving settings file "/Library/Application Support/BOINC Data/slots/3/boinc_190be1c2cde0e3f8/boinc_190be1c2cde0e3f8.vbox" with version "1.16-macosx"
00:00:04.056988 nspr-2   Saving settings file "/Library/Application Support/BOINC Data/slots/3/boinc_190be1c2cde0e3f8/boinc_190be1c2cde0e3f8.vbox" with version "1.16-macosx"
00:00:04.102286 nspr-2   Saving settings file "/Library/Application Support/BOINC Data/projects/virtualbox/VirtualBox.xml" with version "1.12-macosx"
00:00:04.203671 nspr-5   ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:04.204318 nspr-5   ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:04.205224 nspr-4   Saving settings file "/Library/Application Support/BOINC Data/slots/4/boinc_1d0f71eb87940538/boinc_1d0f71eb87940538.vbox" with version "1.16-macosx"
00:00:04.266313 nspr-4   Saving settings file "/Library/Application Support/BOINC Data/slots/4/boinc_1d0f71eb87940538/boinc_1d0f71eb87940538.vbox" with version "1.16-macosx"
00:00:04.313902 nspr-4   Saving settings file "/Library/Application Support/BOINC Data/slots/4/boinc_1d0f71eb87940538/boinc_1d0f71eb87940538.vbox" with version "1.16-macosx"
00:00:04.374366 nspr-4   ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:04.374745 nspr-2   ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:04.387722 nspr-2   WARNING [COM]: aRC=NS_ERROR_FAILURE (0x80004005) aIID={16ced992-5fdc-4aba-aff5-6a39bbd7c38b} aComponent={HostWrap} aText={Could not load the Host USB Proxy service: VERR_GENERAL_FAILURE}, preserve=true  aResultDetail=0
00:00:04.387939 nspr-4   WARNING [COM]: aRC=NS_ERROR_FAILURE (0x80004005) aIID={16ced992-5fdc-4aba-aff5-6a39bbd7c38b} aComponent={HostWrap} aText={Could not load the Host USB Proxy service: VERR_GENERAL_FAILURE}, preserve=true  aResultDetail=0
00:00:04.392746 nspr-2   ERROR [COM]: aRC=NS_ERROR_FAILURE (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:04.436515 nspr-5   Launched VM: 985739408 pid: 77449 (0x12e89) frontend: headless name: boinc_1d0f71eb87940538
00:00:04.938648 Watcher  ERROR [COM]: aRC=NS_ERROR_FAILURE (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The virtual machine 'boinc_1d0f71eb87940538' has terminated unexpectedly during startup with exit code 1 (0x1)}, preserve=false aResultDetail=0
00:00:05.085186 nspr-2   ERROR [COM]: aRC=NS_ERROR_FAILURE (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:05.131511 nspr-2   Saving settings file "/Library/Application Support/BOINC Data/slots/4/boinc_1d0f71eb87940538/boinc_1d0f71eb87940538.vbox" with version "1.16-macosx"
00:00:05.179825 nspr-3   Saving settings file "/Library/Application Support/BOINC Data/slots/4/boinc_1d0f71eb87940538/boinc_1d0f71eb87940538.vbox" with version "1.16-macosx"
00:00:05.267113 nspr-3   Saving settings file "/Library/Application Support/BOINC Data/projects/virtualbox/VirtualBox.xml" with version "1.12-macosx"
00:00:10.382626 main     VirtualBox: object deletion starts
00:00:10.383185 main     HostDnsMonitor: shutting down ...
00:00:10.383247 main     HostDnsMonitor: shut down
00:00:10.383784 Watcher  ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0
00:00:10.383858 main     VirtualBox: object deleted

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

Raw-mode Supported:              no
Exclusive HW virtualization use: off
Default hard disk format:        VDI
VRDE auth library:               VBoxAuth
Webservice auth. library:        VBoxAuth
Remote desktop ExtPack:          
Log history count:               3
Default frontend:                
Default audio driver:            CoreAudio
Autostart database path:         
Default Guest Additions ISO:     /Applications/VirtualBox.app/Contents/MacOS/VBoxGuestAdditions.iso
Logging Level:                   all
Proxy Mode:                      System
Proxy URL:                       

2020-09-23 09:26:10 (77328): 
Command: VBoxManage -q list hostinfo 
Exit Code: 0
Output:
Host Information:

Host time: 2020-09-23T13:26:10.947000000Z
Processor online count: 4
Processor count: 4
Processor online core count: 2
Processor core count: 2
Processor supports HW virtualization: yes
Processor supports PAE: yes
Processor supports long mode: yes
Processor supports nested paging: no
Processor supports unrestricted guest: no
Processor supports nested HW virtualization: no
Processor#0 speed: 2600 MHz
Processor#0 description: Intel(R) Core(TM) i5-4278U CPU @ 2.60GHz
Processor#1 speed: 2600 MHz
Processor#1 description: Intel(R) Core(TM) i5-4278U CPU @ 2.60GHz
Processor#2 speed: 2600 MHz
Processor#2 description: Intel(R) Core(TM) i5-4278U CPU @ 2.60GHz
Processor#3 speed: 2600 MHz
Processor#3 description: Intel(R) Core(TM) i5-4278U CPU @ 2.60GHz
Memory size: 8192 MByte
Memory available: 2868 MByte
Operating system: Darwin
Operating system version: 19.6.0

2020-09-23 09:26:11 (77328): 
Command: VBoxManage -q showvminfo "boinc_1d0f71eb87940538" --machinereadable 
Exit Code: -2135228415
Output:
VBoxManage: error: Could not find a registered machine named 'boinc_1d0f71eb87940538'
VBoxManage: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee nsISupports
VBoxManage: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2699 of file VBoxManageInfo.cpp

2020-09-23 09:26:11 (77328): 
Command: VBoxManage -q showhdinfo "/Library/Application Support/BOINC Data/slots/4/vm_image.vdi" 
Exit Code: -2135228412
Output:
VBoxManage: error: Could not find file for the medium '/Library/Application Support/BOINC Data/slots/4/vm_image.vdi' (VERR_FILE_NOT_FOUND)
VBoxManage: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee nsISupports
VBoxManage: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp

2020-09-23 09:26:11 (77328): 
Command: VBoxManage -q createvm --name "boinc_1d0f71eb87940538" --basefolder "/Library/Application Support/BOINC Data/slots/4" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_1d0f71eb87940538' is created and registered.
UUID: 5ccf1536-8453-49ce-a469-ff581162470b
Settings file: '/Library/Application Support/BOINC Data/slots/4/boinc_1d0f71eb87940538/boinc_1d0f71eb87940538.vbox'

2020-09-23 09:26:11 (77328): 
Command: VBoxManage -q modifyvm "boinc_1d0f71eb87940538" --description "07953510_47_0" 
Exit Code: 0
Output:

2020-09-23 09:26:11 (77328): 
Command: VBoxManage -q modifyvm "boinc_1d0f71eb87940538" --memory 3072 
Exit Code: 0
Output:

2020-09-23 09:26:11 (77328): 
Command: VBoxManage -q modifyvm "boinc_1d0f71eb87940538" --cpus 1 
Exit Code: 0
Output:

2020-09-23 09:26:11 (77328): 
Command: VBoxManage -q modifyvm "boinc_1d0f71eb87940538" --acpi on --ioapic on 
Exit Code: 0
Output:

2020-09-23 09:26:11 (77328): 
Command: VBoxManage -q modifyvm "boinc_1d0f71eb87940538" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2020-09-23 09:26:11 (77328): 
Command: VBoxManage -q modifyvm "boinc_1d0f71eb87940538" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2020-09-23 09:26:11 (77328): 
Command: VBoxManage -q modifyvm "boinc_1d0f71eb87940538" --cableconnected1 on 
Exit Code: 0
Output:

2020-09-23 09:26:11 (77328): 
Command: VBoxManage -q modifyvm "boinc_1d0f71eb87940538" --usb off 
Exit Code: 0
Output:

2020-09-23 09:26:11 (77328): 
Command: VBoxManage -q modifyvm "boinc_1d0f71eb87940538" --uart1 off --uart2 off 
Exit Code: 0
Output:

2020-09-23 09:26:11 (77328): 
Command: VBoxManage -q modifyvm "boinc_1d0f71eb87940538" --audio none 
Exit Code: 0
Output:

2020-09-23 09:26:11 (77328): 
Command: VBoxManage -q modifyvm "boinc_1d0f71eb87940538" --clipboard disabled 
Exit Code: 0
Output:

2020-09-23 09:26:11 (77328): 
Command: VBoxManage -q modifyvm "boinc_1d0f71eb87940538" --draganddrop disabled 
Exit Code: 0
Output:

2020-09-23 09:26:12 (77328): 
Command: VBoxManage -q storagectl "boinc_1d0f71eb87940538" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2020-09-23 09:26:12 (77328): 
Command: VBoxManage -q storageattach "boinc_1d0f71eb87940538" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "/Library/Application Support/BOINC Data/slots/4/vm_isocontext.iso" 
Exit Code: 0
Output:

2020-09-23 09:26:12 (77328): 
Command: VBoxManage -q storageattach "boinc_1d0f71eb87940538" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "/Applications/VirtualBox.app/Contents/MacOS/VBoxGuestAdditions.iso" 
Exit Code: -2147024809
Output:
VBoxManage: error: Cannot register the DVD image '/Applications/VirtualBox.app/Contents/MacOS/VBoxGuestAdditions.iso' {2dae15b7-9966-4a1e-9fda-1e45fcecc4c0} because a CD/DVD image '/Applications/VirtualBox.app/Contents/MacOS/VBoxGuestAdditions.iso' with UUID {3bb21af5-a790-46ab-91b3-8d7d68d94a85} already exists
VBoxManage: error: Details: code NS_ERROR_INVALID_ARG (0x80070057), component VirtualBoxWrap, interface IVirtualBox, callee nsISupports
VBoxManage: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp
VBoxManage: error: Invalid UUID or filename "/Applications/VirtualBox.app/Contents/MacOS/VBoxGuestAdditions.iso"

2020-09-23 09:26:13 (77328): 
Command: VBoxManage -q storageattach "boinc_1d0f71eb87940538" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "/Applications/VirtualBox.app/Contents/MacOS/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2020-09-23 09:26:13 (77328): 
Command: VBoxManage -q bandwidthctl "boinc_1d0f71eb87940538" add "boinc_1d0f71eb87940538_net" --type network --limit 1024G 
Exit Code: 0
Output:

2020-09-23 09:26:13 (77328): 
Command: VBoxManage -q sharedfolder add "boinc_1d0f71eb87940538" --name "shared" --hostpath "/Library/Application Support/BOINC Data/slots/4/shared"
Exit Code: 0
Output:

2020-09-23 09:26:14 (77328): 
Command: VBoxManage -q startvm "boinc_1d0f71eb87940538" --type headless
Exit Code: 1
Output:
VBoxManage: error: The virtual machine 'boinc_1d0f71eb87940538' has terminated unexpectedly during startup with exit code 1 (0x1)
VBoxManage: error: Details: code NS_ERROR_FAILURE (0x80004005), component MachineWrap, interface IMachine
Waiting for VM "boinc_1d0f71eb87940538" to power on...

2020-09-23 09:26:14 (77328): 
Command: VBoxManage -q snapshot "boinc_1d0f71eb87940538" list 
Exit Code: 0
Output:
This machine does not have any snapshots

2020-09-23 09:26:14 (77328): 
Command: VBoxManage -q bandwidthctl "boinc_1d0f71eb87940538" remove "boinc_1d0f71eb87940538_net" 
Exit Code: 0
Output:

2020-09-23 09:26:14 (77328): 
Command: VBoxManage -q storagectl "boinc_1d0f71eb87940538" --name "Hard Disk Controller" --remove 
Exit Code: 0
Output:

2020-09-23 09:26:14 (77328): 
Command: VBoxManage -q unregistervm "boinc_1d0f71eb87940538" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

2020-09-23 09:26:14 (77328): 
Command: VBoxManage -q closemedium dvd "/Library/Application Support/BOINC Data/slots/4/vm_isocontext.iso" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

09:26:19 (77328): called boinc_finish(1)

</stderr_txt>
]]>


©2024 COPYRIGHT 2017-2018 NCN