Name | 07970456_30_3 |
Workunit | 7702705 |
Created | 6 Oct 2020, 14:25:10 UTC |
Sent | 6 Oct 2020, 15:22:25 UTC |
Report deadline | 11 Oct 2020, 15:22:25 UTC |
Received | 7 Oct 2020, 4:32:28 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | -2147467259 (0x80004005) Unknown error code |
Computer ID | 8612 |
Run time | 17 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 4.01 GFLOPS |
Application version | boinc2docker v1.14 (vbox64_mt) windows_x86_64 |
Peak working set size | 10.94 MB |
Peak swap size | 6.20 MB |
Peak disk usage | 498.78 MB |
<core_client_version>7.16.11</core_client_version> <![CDATA[ <message> Unspecified error (0x80004005) - exit code 2147500037 (0x80004005)</message> <stderr_txt> 2020-10-06 13:37:04 (19564): Detected: vboxwrapper 26202 2020-10-06 13:37:04 (19564): Detected: BOINC client v7.16.11 2020-10-06 13:37:04 (19564): Detected: VirtualBox VboxManage Interface (Version: 6.1.12) 2020-10-06 13:37:05 (19564): Create VM. (boinc_bd8d61e4f3b9e361, slot#14) 2020-10-06 13:37:05 (19564): Updating drive controller type and model for desired configuration. 2020-10-06 13:37:06 (19564): Setting Memory Size for VM. (3072MB) 2020-10-06 13:37:06 (19564): Setting CPU Count for VM. (1) 2020-10-06 13:37:06 (19564): Setting Chipset Options for VM. 2020-10-06 13:37:06 (19564): Setting Boot Options for VM. 2020-10-06 13:37:07 (19564): Setting Network Configuration for NAT. 2020-10-06 13:37:07 (19564): Enabling VM Network Access. 2020-10-06 13:37:07 (19564): Disabling USB Support for VM. 2020-10-06 13:37:07 (19564): Disabling COM Port Support for VM. 2020-10-06 13:37:08 (19564): Disabling LPT Port Support for VM. 2020-10-06 13:37:08 (19564): Disabling Audio Support for VM. 2020-10-06 13:37:08 (19564): Disabling Clipboard Support for VM. 2020-10-06 13:37:09 (19564): Disabling Drag and Drop Support for VM. 2020-10-06 13:37:09 (19564): Adding storage controller(s) to VM. 2020-10-06 13:37:09 (19564): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso) 2020-10-06 13:37:09 (19564): Adding VirtualBox Guest Additions to VM. 2020-10-06 13:37:10 (19564): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2020-10-06 13:37:10 (19564): Enabling shared directory for VM. 2020-10-06 13:37:10 (19564): Starting VM using VBoxManage interface. (boinc_bd8d61e4f3b9e361, slot#14) 2020-10-06 13:37:12 (19564): Error in start VM for VM: -2147467259 Command: VBoxManage -q startvm "boinc_bd8d61e4f3b9e361" --type headless Output: Waiting for VM "boinc_bd8d61e4f3b9e361" to power on... VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: AMD-V is disabled in the BIOS (or by the host OS) (VERR_SVM_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2020-10-06 13:37:12 (19564): VM failed to start. 2020-10-06 13:37:12 (19564): Could not start 2020-10-06 13:37:12 (19564): ERROR: VM failed to start 2020-10-06 13:37:12 (19564): Powering off VM. 2020-10-06 13:37:12 (19564): Deregistering VM. (boinc_bd8d61e4f3b9e361, slot#14) 2020-10-06 13:37:12 (19564): Removing network bandwidth throttle group from VM. 2020-10-06 13:37:13 (19564): Removing VM from VirtualBox. 2020-10-06 13:37:13 (19564): Removing virtual ISO 9660 disk from VirtualBox. Hypervisor System Log: 00:00:09.589994 Saving settings file "C:\ProgramData\BOINC\slots\14\boinc_bd8d61e4f3b9e361\boinc_bd8d61e4f3b9e361.vbox" with version "1.16-windows" 00:00:09.667361 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.668628 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.668755 Saving settings file "C:\Users\tfenu\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:09.677817 Saving settings file "C:\Users\tfenu\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:09.682175 Saving settings file "C:\ProgramData\BOINC\slots\12\boinc_b3ad3cd557585cdb\boinc_b3ad3cd557585cdb.vbox" with version "1.16-windows" 00:00:09.873802 Saving settings file "C:\ProgramData\BOINC\slots\14\boinc_bd8d61e4f3b9e361\boinc_bd8d61e4f3b9e361.vbox" with version "1.16-windows" 00:00:09.949649 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.949974 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.950395 Saving settings file "C:\ProgramData\BOINC\slots\12\boinc_b3ad3cd557585cdb\boinc_b3ad3cd557585cdb.vbox" with version "1.16-windows" 00:00:10.149755 Saving settings file "C:\ProgramData\BOINC\slots\14\boinc_bd8d61e4f3b9e361\boinc_bd8d61e4f3b9e361.vbox" with version "1.16-windows" 00:00:10.229699 Saving settings file "C:\ProgramData\BOINC\slots\12\boinc_b3ad3cd557585cdb\boinc_b3ad3cd557585cdb.vbox" with version "1.16-windows" 00:00:10.413565 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:10.414932 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:10.415075 Saving settings file "C:\Users\tfenu\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:10.424575 Saving settings file "C:\Users\tfenu\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:10.430002 Saving settings file "C:\ProgramData\BOINC\slots\14\boinc_bd8d61e4f3b9e361\boinc_bd8d61e4f3b9e361.vbox" with version "1.16-windows" 00:00:10.492689 Saving settings file "C:\ProgramData\BOINC\slots\12\boinc_b3ad3cd557585cdb\boinc_b3ad3cd557585cdb.vbox" with version "1.16-windows" 00:00:10.680566 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:10.680919 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:10.681324 Saving settings file "C:\ProgramData\BOINC\slots\14\boinc_bd8d61e4f3b9e361\boinc_bd8d61e4f3b9e361.vbox" with version "1.16-windows" 00:00:10.761532 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:10.761670 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:10.768152 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:10.943868 Saving settings file "C:\ProgramData\BOINC\slots\14\boinc_bd8d61e4f3b9e361\boinc_bd8d61e4f3b9e361.vbox" with version "1.16-windows" 00:00:10.963828 Saving settings file "C:\ProgramData\BOINC\slots\11\boinc_a80a7b095d3edc5a\boinc_a80a7b095d3edc5a.vbox" with version "1.16-windows" 00:00:11.016421 Launched VM: 69097744 pid: 18680 (0x48f8) frontend: headless name: boinc_b3ad3cd557585cdb 00:00:11.050115 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:11.206278 Saving settings file "C:\ProgramData\BOINC\slots\14\boinc_bd8d61e4f3b9e361\boinc_bd8d61e4f3b9e361.vbox" with version "1.16-windows" 00:00:11.375716 Saving settings file "C:\Users\tfenu\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:11.475538 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:11.475647 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:11.481457 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:11.725750 Launched VM: 69135616 pid: 6476 (0x194c) frontend: headless name: boinc_bd8d61e4f3b9e361 00:00:12.891401 Saving settings file "C:\ProgramData\BOINC\slots\12\boinc_b3ad3cd557585cdb\boinc_b3ad3cd557585cdb.vbox" with version "1.16-windows" 00:00:12.971606 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:13.289317 Saving settings file "C:\Users\tfenu\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:13.578904 Saving settings file "C:\ProgramData\BOINC\slots\14\boinc_bd8d61e4f3b9e361\boinc_bd8d61e4f3b9e361.vbox" with version "1.16-windows" 00:00:13.651279 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:13.980682 Saving settings file "C:\Users\tfenu\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:19.262895 main VirtualBox: object deletion starts 00:00:19.263407 main HostDnsMonitor: shutting down ... 00:00:19.263434 main HostDnsMonitor: shut down 00:00:19.264757 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:19.264921 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: ollers:1 Maximum ICH9 Floppy Controllers: 1 Maximum Floppy Port count: 1 Maximum Devices per Floppy Port: 2 Default machine folder: C:\Users\tfenu\VirtualBox VMs Raw-mode Supported: no Exclusive HW virtualization use: off Default hard disk format: VDI VRDE auth library: VBoxAuth Webservice auth. library: VBoxAuth Remote desktop ExtPack: Log history count: 3 Default frontend: Default audio driver: DirectSound Autostart database path: Default Guest Additions ISO: C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso Logging Level: all Proxy Mode: System Proxy URL: 2020-10-06 13:37:04 (19564): Command: VBoxManage -q list hostinfo Exit Code: 0 Output: Host Information: Host time: 2020-10-06T18:37:04.717000000Z Processor online count: 12 Processor count: 12 Processor online core count: 6 Processor core count: 6 Processor supports HW virtualization: no Processor supports PAE: yes Processor supports long mode: yes Processor supports nested paging: no Processor supports unrestricted guest: no Processor supports nested HW virtualization: no Processor#0 speed: unknown Processor#0 description: AMD Ryzen 5 1600 Six-Core Processor Processor#1 speed: unknown Processor#1 description: AMD Ryzen 5 1600 Six-Core Processor Processor#2 speed: unknown Processor#2 description: AMD Ryzen 5 1600 Six-Core Processor Processor#3 speed: unknown Processor#3 description: AMD Ryzen 5 1600 Six-Core Processor Processor#4 speed: unknown Processor#4 description: AMD Ryzen 5 1600 Six-Core Processor Processor#5 speed: unknown Processor#5 description: AMD Ryzen 5 1600 Six-Core Processor Processor#6 speed: unknown Processor#6 description: AMD Ryzen 5 1600 Six-Core Processor Processor#7 speed: unknown Processor#7 description: AMD Ryzen 5 1600 Six-Core Processor Processor#8 speed: unknown Processor#8 description: AMD Ryzen 5 1600 Six-Core Processor Processor#9 speed: unknown Processor#9 description: AMD Ryzen 5 1600 Six-Core Processor Processor#10 speed: unknown Processor#10 description: AMD Ryzen 5 1600 Six-Core Processor Processor#11 speed: unknown Processor#11 description: AMD Ryzen 5 1600 Six-Core Processor Memory size: 16331 MByte Memory available: 9835 MByte Operating system: Windows 10 Operating system version: 10.0.19041 2020-10-06 13:37:05 (19564): Command: VBoxManage -q showvminfo "boinc_bd8d61e4f3b9e361" --machinereadable Exit Code: -2135228415 Output: VBoxManage.exe: error: Could not find a registered machine named 'boinc_bd8d61e4f3b9e361' VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2715 of file VBoxManageInfo.cpp 2020-10-06 13:37:05 (19564): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\14/vm_image.vdi" Exit Code: -2135228412 Output: VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\14\vm_image.vdi' (VERR_FILE_NOT_FOUND) VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp 2020-10-06 13:37:05 (19564): Command: VBoxManage -q createvm --name "boinc_bd8d61e4f3b9e361" --basefolder "C:\ProgramData\BOINC\slots\14" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_bd8d61e4f3b9e361' is created and registered. UUID: 56c06f7e-5975-4d12-8c83-cbccd5459b80 Settings file: 'C:\ProgramData\BOINC\slots\14\boinc_bd8d61e4f3b9e361\boinc_bd8d61e4f3b9e361.vbox' 2020-10-06 13:37:06 (19564): Command: VBoxManage -q modifyvm "boinc_bd8d61e4f3b9e361" --description "07970456_30_3" Exit Code: 0 Output: 2020-10-06 13:37:06 (19564): Command: VBoxManage -q modifyvm "boinc_bd8d61e4f3b9e361" --memory 3072 Exit Code: 0 Output: 2020-10-06 13:37:06 (19564): Command: VBoxManage -q modifyvm "boinc_bd8d61e4f3b9e361" --cpus 1 Exit Code: 0 Output: 2020-10-06 13:37:06 (19564): Command: VBoxManage -q modifyvm "boinc_bd8d61e4f3b9e361" --acpi on --ioapic on Exit Code: 0 Output: 2020-10-06 13:37:07 (19564): Command: VBoxManage -q modifyvm "boinc_bd8d61e4f3b9e361" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2020-10-06 13:37:07 (19564): Command: VBoxManage -q modifyvm "boinc_bd8d61e4f3b9e361" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2020-10-06 13:37:07 (19564): Command: VBoxManage -q modifyvm "boinc_bd8d61e4f3b9e361" --cableconnected1 on Exit Code: 0 Output: 2020-10-06 13:37:07 (19564): Command: VBoxManage -q modifyvm "boinc_bd8d61e4f3b9e361" --usb off Exit Code: 0 Output: 2020-10-06 13:37:08 (19564): Command: VBoxManage -q modifyvm "boinc_bd8d61e4f3b9e361" --uart1 off --uart2 off Exit Code: 0 Output: 2020-10-06 13:37:08 (19564): Command: VBoxManage -q modifyvm "boinc_bd8d61e4f3b9e361" --lpt1 off --lpt2 off Exit Code: 0 Output: 2020-10-06 13:37:08 (19564): Command: VBoxManage -q modifyvm "boinc_bd8d61e4f3b9e361" --audio none Exit Code: 0 Output: 2020-10-06 13:37:09 (19564): Command: VBoxManage -q modifyvm "boinc_bd8d61e4f3b9e361" --clipboard disabled Exit Code: 0 Output: 2020-10-06 13:37:09 (19564): Command: VBoxManage -q modifyvm "boinc_bd8d61e4f3b9e361" --draganddrop disabled Exit Code: 0 Output: 2020-10-06 13:37:09 (19564): Command: VBoxManage -q storagectl "boinc_bd8d61e4f3b9e361" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2020-10-06 13:37:09 (19564): Command: VBoxManage -q storageattach "boinc_bd8d61e4f3b9e361" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\ProgramData\BOINC\slots\14/vm_isocontext.iso" Exit Code: 0 Output: 2020-10-06 13:37:10 (19564): Command: VBoxManage -q storageattach "boinc_bd8d61e4f3b9e361" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2020-10-06 13:37:10 (19564): Command: VBoxManage -q bandwidthctl "boinc_bd8d61e4f3b9e361" add "boinc_bd8d61e4f3b9e361_net" --type network --limit 1024G Exit Code: 0 Output: 2020-10-06 13:37:10 (19564): Command: VBoxManage -q sharedfolder add "boinc_bd8d61e4f3b9e361" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\14/shared" Exit Code: 0 Output: 2020-10-06 13:37:12 (19564): Command: VBoxManage -q startvm "boinc_bd8d61e4f3b9e361" --type headless Exit Code: -2147467259 Output: Waiting for VM "boinc_bd8d61e4f3b9e361" to power on... VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: AMD-V is disabled in the BIOS (or by the host OS) (VERR_SVM_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2020-10-06 13:37:12 (19564): Command: VBoxManage -q snapshot "boinc_bd8d61e4f3b9e361" list Exit Code: -108 Output: This machine does not have any snapshots 2020-10-06 13:37:13 (19564): Command: VBoxManage -q bandwidthctl "boinc_bd8d61e4f3b9e361" remove "boinc_bd8d61e4f3b9e361_net" Exit Code: 0 Output: VBoxManage.exe: error: Bandwidth groups cannot be deleted while the VM is running 2020-10-06 13:37:13 (19564): Command: VBoxManage -q unregistervm "boinc_bd8d61e4f3b9e361" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 2020-10-06 13:37:13 (19564): Command: VBoxManage -q closemedium dvd "C:\ProgramData\BOINC\slots\14/vm_isocontext.iso" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 13:37:18 (19564): called boinc_finish(-2147467259) </stderr_txt> ]]>
©2025 COPYRIGHT 2017-2018 NCN