Task 9879517

Name 07970607_11_3
Workunit 7705870
Created 8 Oct 2020, 8:16:44 UTC
Sent 8 Oct 2020, 9:33:22 UTC
Report deadline 13 Oct 2020, 9:33:22 UTC
Received 8 Oct 2020, 10:33:00 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status -2147467259 (0x80004005) Unknown error code
Computer ID 9106
Run time 25 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 4.49 GFLOPS
Application version boinc2docker v1.14 (vbox64_mt)
windows_x86_64
Peak working set size 11.46 MB
Peak swap size 6.18 MB
Peak disk usage 227.22 MB

Stderr output

<core_client_version>7.16.11</core_client_version>
<![CDATA[
<message>
Unspecified error
 (0x80004005) - exit code 2147500037 (0x80004005)</message>
<stderr_txt>
2020-10-08 03:45:12 (8620): Detected: vboxwrapper 26202
2020-10-08 03:45:12 (8620): Detected: BOINC client v7.16.11
2020-10-08 03:45:12 (8620): Detected: VirtualBox VboxManage Interface (Version: 6.1.12)
2020-10-08 03:45:13 (8620): Create VM. (boinc_082bd02e0b5aba8f, slot#2)
2020-10-08 03:45:13 (8620): Updating drive controller type and model for desired configuration.
2020-10-08 03:45:14 (8620): Setting Memory Size for VM. (3072MB)
2020-10-08 03:45:14 (8620): Setting CPU Count for VM. (1)
2020-10-08 03:45:14 (8620): Setting Chipset Options for VM.
2020-10-08 03:45:15 (8620): Setting Boot Options for VM.
2020-10-08 03:45:15 (8620): Setting Network Configuration for NAT.
2020-10-08 03:45:16 (8620): Enabling VM Network Access.
2020-10-08 03:45:16 (8620): Disabling USB Support for VM.
2020-10-08 03:45:16 (8620): Disabling COM Port Support for VM.
2020-10-08 03:45:17 (8620): Disabling LPT Port Support for VM.
2020-10-08 03:45:17 (8620): Disabling Audio Support for VM.
2020-10-08 03:45:17 (8620): Disabling Clipboard Support for VM.
2020-10-08 03:45:18 (8620): Disabling Drag and Drop Support for VM.
2020-10-08 03:45:18 (8620): Adding storage controller(s) to VM.
2020-10-08 03:45:18 (8620): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso)
2020-10-08 03:45:19 (8620): Adding VirtualBox Guest Additions to VM.
2020-10-08 03:45:20 (8620): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2020-10-08 03:45:20 (8620): Enabling shared directory for VM.
2020-10-08 03:45:21 (8620): Starting VM using VBoxManage interface. (boinc_082bd02e0b5aba8f, slot#2)
2020-10-08 03:45:24 (8620): Error in start VM for VM: -2147467259
Command:
VBoxManage -q startvm "boinc_082bd02e0b5aba8f" --type headless
Output:
Waiting for VM "boinc_082bd02e0b5aba8f" to power on...
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: AMD-V is disabled in the BIOS (or by the host OS) (VERR_SVM_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole

2020-10-08 03:45:24 (8620): VM failed to start.
2020-10-08 03:45:24 (8620): Could not start 
2020-10-08 03:45:24 (8620): ERROR: VM failed to start
2020-10-08 03:45:24 (8620): Powering off VM.
2020-10-08 03:45:24 (8620): Deregistering VM. (boinc_082bd02e0b5aba8f, slot#2)
2020-10-08 03:45:24 (8620): Removing network bandwidth throttle group from VM.
2020-10-08 03:45:24 (8620): Removing VM from VirtualBox.
2020-10-08 03:45:24 (8620): Removing virtual ISO 9660 disk from VirtualBox.

    Hypervisor System Log:

00:00:26.021723          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:26.155795          Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_8935014a4871a483\boinc_8935014a4871a483.vbox" with version "1.16-windows"
00:00:26.253182          Saving settings file "C:\ProgramData\BOINC\slots\6\boinc_86cdf84bcdaf6e8f\boinc_86cdf84bcdaf6e8f.vbox" with version "1.16-windows"
00:00:26.275207          Launched VM: 69159056 pid: 13020 (0x32dc) frontend: headless name: boinc_d129ba6361da1b92
00:00:26.453667          Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_8935014a4871a483\boinc_8935014a4871a483.vbox" with version "1.16-windows"
00:00:26.526802          Saving settings file "C:\ProgramData\BOINC\slots\6\boinc_86cdf84bcdaf6e8f\boinc_86cdf84bcdaf6e8f.vbox" with version "1.16-windows"
00:00:26.729344          Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_8935014a4871a483\boinc_8935014a4871a483.vbox" with version "1.16-windows"
00:00:26.829290          Saving settings file "C:\ProgramData\BOINC\slots\6\boinc_86cdf84bcdaf6e8f\boinc_86cdf84bcdaf6e8f.vbox" with version "1.16-windows"
00:00:26.996854          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:26.998154          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:26.998300          Saving settings file "C:\Users\vulne\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:27.021243          Saving settings file "C:\Users\vulne\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:27.080395          Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_8935014a4871a483\boinc_8935014a4871a483.vbox" with version "1.16-windows"
00:00:27.168681          Saving settings file "C:\ProgramData\BOINC\slots\6\boinc_86cdf84bcdaf6e8f\boinc_86cdf84bcdaf6e8f.vbox" with version "1.16-windows"
00:00:27.327258          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:27.327599          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:27.328135          Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_8935014a4871a483\boinc_8935014a4871a483.vbox" with version "1.16-windows"
00:00:27.410763          Saving settings file "C:\ProgramData\BOINC\slots\6\boinc_86cdf84bcdaf6e8f\boinc_86cdf84bcdaf6e8f.vbox" with version "1.16-windows"
00:00:27.600943          Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_8935014a4871a483\boinc_8935014a4871a483.vbox" with version "1.16-windows"
00:00:27.706913          Saving settings file "C:\ProgramData\BOINC\slots\6\boinc_86cdf84bcdaf6e8f\boinc_86cdf84bcdaf6e8f.vbox" with version "1.16-windows"
00:00:27.860095          Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_8935014a4871a483\boinc_8935014a4871a483.vbox" with version "1.16-windows"
00:00:27.988187          Saving settings file "C:\ProgramData\BOINC\slots\6\boinc_86cdf84bcdaf6e8f\boinc_86cdf84bcdaf6e8f.vbox" with version "1.16-windows"
00:00:28.151712          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:28.151878          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:28.157388          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:28.243824          Saving settings file "C:\ProgramData\BOINC\slots\6\boinc_86cdf84bcdaf6e8f\boinc_86cdf84bcdaf6e8f.vbox" with version "1.16-windows"
00:00:28.408297          Launched VM: 68801376 pid: 9448 (0x24e8) frontend: headless name: boinc_8935014a4871a483
00:00:28.524066          Saving settings file "C:\ProgramData\BOINC\slots\6\boinc_86cdf84bcdaf6e8f\boinc_86cdf84bcdaf6e8f.vbox" with version "1.16-windows"
00:00:28.540726          Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_d129ba6361da1b92\boinc_d129ba6361da1b92.vbox" with version "1.16-windows"
00:00:28.660143          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:28.760454          Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_d129ba6361da1b92\boinc_d129ba6361da1b92.vbox" with version "1.16-windows"
00:00:28.911708          Saving settings file "C:\ProgramData\BOINC\slots\6\boinc_86cdf84bcdaf6e8f\boinc_86cdf84bcdaf6e8f.vbox" with version "1.16-windows"
00:00:29.080268          Saving settings file "C:\Users\vulne\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:29.099863          Saving settings file "C:\ProgramData\BOINC\slots\6\boinc_86cdf84bcdaf6e8f\boinc_86cdf84bcdaf6e8f.vbox" with version "1.16-windows"
00:00:29.422594          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:29.423941          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:29.424241          Saving settings file "C:\Users\vulne\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:29.442852          Saving settings file "C:\Users\vulne\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:29.458780          Saving settings file "C:\ProgramData\BOINC\slots\6\boinc_86cdf84bcdaf6e8f\boinc_86cdf84bcdaf6e8f.vbox" with version "1.16-windows"
00:00:29.732206          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:29.732607          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:29.733093          Saving settings file "C:\ProgramData\BOINC\slots\6\boinc_86cdf84bcdaf6e8f\boinc_86cdf84bcdaf6e8f.vbox" with version "1.16-windows"
00:00:30.016570          Saving settings file "C:\ProgramData\BOINC\slots\6\boinc_86cdf84bcdaf6e8f\boinc_86cdf84bcdaf6e8f.vbox" with version "1.16-windows"
00:00:30.314822          Saving settings file "C:\ProgramData\BOINC\slots\6\boinc_86cdf84bcdaf6e8f\boinc_86cdf84bcdaf6e8f.vbox" with version "1.16-windows"

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

auth library:               VBoxAuth
Webservice auth. library:        VBoxAuth
Remote desktop ExtPack:          
Log history count:               3
Default frontend:                
Default audio driver:            DirectSound
Autostart database path:         
Default Guest Additions ISO:     C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso
Logging Level:                   all
Proxy Mode:                      System
Proxy URL:                       

2020-10-08 03:45:12 (8620): 
Command: VBoxManage -q list hostinfo 
Exit Code: 0
Output:
Host Information:

Host time: 2020-10-08T09:45:12.770000000Z
Processor online count: 16
Processor count: 16
Processor online core count: 8
Processor core count: 8
Processor supports HW virtualization: no
Processor supports PAE: yes
Processor supports long mode: yes
Processor supports nested paging: no
Processor supports unrestricted guest: no
Processor supports nested HW virtualization: no
Processor#0 speed: unknown
Processor#0 description: AMD Ryzen 7 2700X Eight-Core Processor
Processor#1 speed: unknown
Processor#1 description: AMD Ryzen 7 2700X Eight-Core Processor
Processor#2 speed: unknown
Processor#2 description: AMD Ryzen 7 2700X Eight-Core Processor
Processor#3 speed: unknown
Processor#3 description: AMD Ryzen 7 2700X Eight-Core Processor
Processor#4 speed: unknown
Processor#4 description: AMD Ryzen 7 2700X Eight-Core Processor
Processor#5 speed: unknown
Processor#5 description: AMD Ryzen 7 2700X Eight-Core Processor
Processor#6 speed: unknown
Processor#6 description: AMD Ryzen 7 2700X Eight-Core Processor
Processor#7 speed: unknown
Processor#7 description: AMD Ryzen 7 2700X Eight-Core Processor
Processor#8 speed: unknown
Processor#8 description: AMD Ryzen 7 2700X Eight-Core Processor
Processor#9 speed: unknown
Processor#9 description: AMD Ryzen 7 2700X Eight-Core Processor
Processor#10 speed: unknown
Processor#10 description: AMD Ryzen 7 2700X Eight-Core Processor
Processor#11 speed: unknown
Processor#11 description: AMD Ryzen 7 2700X Eight-Core Processor
Processor#12 speed: unknown
Processor#12 description: AMD Ryzen 7 2700X Eight-Core Processor
Processor#13 speed: unknown
Processor#13 description: AMD Ryzen 7 2700X Eight-Core Processor
Processor#14 speed: unknown
Processor#14 description: AMD Ryzen 7 2700X Eight-Core Processor
Processor#15 speed: unknown
Processor#15 description: AMD Ryzen 7 2700X Eight-Core Processor
Memory size: 32718 MByte
Memory available: 23542 MByte
Operating system: Windows 10
Operating system version: 10.0.19041

2020-10-08 03:45:13 (8620): 
Command: VBoxManage -q showvminfo "boinc_082bd02e0b5aba8f" --machinereadable 
Exit Code: -2135228415
Output:
VBoxManage.exe: error: Could not find a registered machine named 'boinc_082bd02e0b5aba8f'
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown
VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2715 of file VBoxManageInfo.cpp

2020-10-08 03:45:13 (8620): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\2/vm_image.vdi" 
Exit Code: -2135228412
Output:
VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\2\vm_image.vdi' (VERR_FILE_NOT_FOUND)
VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp

2020-10-08 03:45:13 (8620): 
Command: VBoxManage -q createvm --name "boinc_082bd02e0b5aba8f" --basefolder "C:\ProgramData\BOINC\slots\2" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_082bd02e0b5aba8f' is created and registered.
UUID: 7f272972-c4d3-4082-b831-d31886fc9544
Settings file: 'C:\ProgramData\BOINC\slots\2\boinc_082bd02e0b5aba8f\boinc_082bd02e0b5aba8f.vbox'

2020-10-08 03:45:14 (8620): 
Command: VBoxManage -q modifyvm "boinc_082bd02e0b5aba8f" --description "07970607_11_3" 
Exit Code: 0
Output:

2020-10-08 03:45:14 (8620): 
Command: VBoxManage -q modifyvm "boinc_082bd02e0b5aba8f" --memory 3072 
Exit Code: 0
Output:

2020-10-08 03:45:14 (8620): 
Command: VBoxManage -q modifyvm "boinc_082bd02e0b5aba8f" --cpus 1 
Exit Code: 0
Output:

2020-10-08 03:45:15 (8620): 
Command: VBoxManage -q modifyvm "boinc_082bd02e0b5aba8f" --acpi on --ioapic on 
Exit Code: 0
Output:

2020-10-08 03:45:15 (8620): 
Command: VBoxManage -q modifyvm "boinc_082bd02e0b5aba8f" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2020-10-08 03:45:16 (8620): 
Command: VBoxManage -q modifyvm "boinc_082bd02e0b5aba8f" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2020-10-08 03:45:16 (8620): 
Command: VBoxManage -q modifyvm "boinc_082bd02e0b5aba8f" --cableconnected1 on 
Exit Code: 0
Output:

2020-10-08 03:45:16 (8620): 
Command: VBoxManage -q modifyvm "boinc_082bd02e0b5aba8f" --usb off 
Exit Code: 0
Output:

2020-10-08 03:45:17 (8620): 
Command: VBoxManage -q modifyvm "boinc_082bd02e0b5aba8f" --uart1 off --uart2 off 
Exit Code: 0
Output:

2020-10-08 03:45:17 (8620): 
Command: VBoxManage -q modifyvm "boinc_082bd02e0b5aba8f" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2020-10-08 03:45:17 (8620): 
Command: VBoxManage -q modifyvm "boinc_082bd02e0b5aba8f" --audio none 
Exit Code: 0
Output:

2020-10-08 03:45:18 (8620): 
Command: VBoxManage -q modifyvm "boinc_082bd02e0b5aba8f" --clipboard disabled 
Exit Code: 0
Output:

2020-10-08 03:45:18 (8620): 
Command: VBoxManage -q modifyvm "boinc_082bd02e0b5aba8f" --draganddrop disabled 
Exit Code: 0
Output:

2020-10-08 03:45:18 (8620): 
Command: VBoxManage -q storagectl "boinc_082bd02e0b5aba8f" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2020-10-08 03:45:19 (8620): 
Command: VBoxManage -q storageattach "boinc_082bd02e0b5aba8f" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\ProgramData\BOINC\slots\2/vm_isocontext.iso" 
Exit Code: 0
Output:

2020-10-08 03:45:20 (8620): 
Command: VBoxManage -q storageattach "boinc_082bd02e0b5aba8f" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2020-10-08 03:45:20 (8620): 
Command: VBoxManage -q bandwidthctl "boinc_082bd02e0b5aba8f" add "boinc_082bd02e0b5aba8f_net" --type network --limit 1024G 
Exit Code: 0
Output:

2020-10-08 03:45:21 (8620): 
Command: VBoxManage -q sharedfolder add "boinc_082bd02e0b5aba8f" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\2/shared"
Exit Code: 0
Output:

2020-10-08 03:45:24 (8620): 
Command: VBoxManage -q startvm "boinc_082bd02e0b5aba8f" --type headless
Exit Code: -2147467259
Output:
Waiting for VM "boinc_082bd02e0b5aba8f" to power on...
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: AMD-V is disabled in the BIOS (or by the host OS) (VERR_SVM_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole

2020-10-08 03:45:24 (8620): 
Command: VBoxManage -q snapshot "boinc_082bd02e0b5aba8f" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2020-10-08 03:45:24 (8620): 
Command: VBoxManage -q bandwidthctl "boinc_082bd02e0b5aba8f" remove "boinc_082bd02e0b5aba8f_net" 
Exit Code: 0
Output:

2020-10-08 03:45:24 (8620): 
Command: VBoxManage -q unregistervm "boinc_082bd02e0b5aba8f" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

2020-10-08 03:45:25 (8620): 
Command: VBoxManage -q closemedium dvd "C:\ProgramData\BOINC\slots\2/vm_isocontext.iso" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

03:45:35 (8620): called boinc_finish(-2147467259)

</stderr_txt>
]]>


©2024 COPYRIGHT 2017-2018 NCN