Task 9891499

Name 07971660_07_2
Workunit 7721187
Created 9 Oct 2020, 6:30:26 UTC
Sent 9 Oct 2020, 6:45:41 UTC
Report deadline 14 Oct 2020, 6:45:41 UTC
Received 10 Oct 2020, 6:53:56 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status -2147467259 (0x80004005) Unknown error code
Computer ID 8734
Run time 12 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 4.42 GFLOPS
Application version boinc2docker v1.14 (vbox64_mt)
windows_x86_64
Peak working set size 10.55 MB
Peak swap size 6.27 MB
Peak disk usage 227.11 MB

Stderr output

<core_client_version>7.16.11</core_client_version>
<![CDATA[
<message>
Unspecified error
 (0x80004005) - exit code 2147500037 (0x80004005)</message>
<stderr_txt>
2020-10-09 02:49:15 (18440): Detected: vboxwrapper 26202
2020-10-09 02:49:15 (18440): Detected: BOINC client v7.16.11
2020-10-09 02:49:16 (18440): Detected: VirtualBox VboxManage Interface (Version: 6.1.12)
2020-10-09 02:49:17 (18440): Create VM. (boinc_63fc7e55e268ce16, slot#7)
2020-10-09 02:49:17 (18440): Updating drive controller type and model for desired configuration.
2020-10-09 02:49:18 (18440): Setting Memory Size for VM. (3072MB)
2020-10-09 02:49:18 (18440): Setting CPU Count for VM. (1)
2020-10-09 02:49:18 (18440): Setting Chipset Options for VM.
2020-10-09 02:49:19 (18440): Setting Boot Options for VM.
2020-10-09 02:49:19 (18440): Setting Network Configuration for NAT.
2020-10-09 02:49:19 (18440): Enabling VM Network Access.
2020-10-09 02:49:20 (18440): Disabling USB Support for VM.
2020-10-09 02:49:20 (18440): Disabling COM Port Support for VM.
2020-10-09 02:49:20 (18440): Disabling LPT Port Support for VM.
2020-10-09 02:49:21 (18440): Disabling Audio Support for VM.
2020-10-09 02:49:21 (18440): Disabling Clipboard Support for VM.
2020-10-09 02:49:21 (18440): Disabling Drag and Drop Support for VM.
2020-10-09 02:49:21 (18440): Adding storage controller(s) to VM.
2020-10-09 02:49:22 (18440): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso)
2020-10-09 02:49:22 (18440): Adding VirtualBox Guest Additions to VM.
2020-10-09 02:49:22 (18440): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2020-10-09 02:49:23 (18440): Enabling shared directory for VM.
2020-10-09 02:49:23 (18440): Starting VM using VBoxManage interface. (boinc_63fc7e55e268ce16, slot#7)
2020-10-09 02:49:27 (18440): Error in start VM for VM: -2147467259
Command:
VBoxManage -q startvm "boinc_63fc7e55e268ce16" --type headless
Output:
Waiting for VM "boinc_63fc7e55e268ce16" to power on...
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole

2020-10-09 02:49:27 (18440): VM failed to start.
2020-10-09 02:49:27 (18440): Could not start 
2020-10-09 02:49:27 (18440): ERROR: VM failed to start
2020-10-09 02:49:27 (18440): Powering off VM.
2020-10-09 02:49:27 (18440): Deregistering VM. (boinc_63fc7e55e268ce16, slot#7)
2020-10-09 02:49:28 (18440): Removing network bandwidth throttle group from VM.
2020-10-09 02:49:28 (18440): Removing VM from VirtualBox.
2020-10-09 02:49:29 (18440): Removing virtual ISO 9660 disk from VirtualBox.

    Hypervisor System Log:

00:00:06.721021          Saving settings file "H:\BOINC\BOINC_DATA\slots\5\boinc_58d939c9dfed65a5\boinc_58d939c9dfed65a5.vbox" with version "1.16-windows"
00:00:06.781416          Saving settings file "H:\BOINC\BOINC_DATA\slots\7\boinc_63fc7e55e268ce16\boinc_63fc7e55e268ce16.vbox" with version "1.16-windows"
00:00:06.881119          Saving settings file "H:\BOINC\BOINC_DATA\slots\6\boinc_59d713cb2ff901cc\boinc_59d713cb2ff901cc.vbox" with version "1.16-windows"
00:00:06.946689          Saving settings file "H:\BOINC\BOINC_DATA\slots\4\boinc_55fed40b3b756a0e\boinc_55fed40b3b756a0e.vbox" with version "1.16-windows"
00:00:07.042262          Saving settings file "H:\BOINC\BOINC_DATA\slots\5\boinc_58d939c9dfed65a5\boinc_58d939c9dfed65a5.vbox" with version "1.16-windows"
00:00:07.089684          Saving settings file "H:\BOINC\BOINC_DATA\slots\7\boinc_63fc7e55e268ce16\boinc_63fc7e55e268ce16.vbox" with version "1.16-windows"
00:00:07.183008          Saving settings file "H:\BOINC\BOINC_DATA\slots\6\boinc_59d713cb2ff901cc\boinc_59d713cb2ff901cc.vbox" with version "1.16-windows"
00:00:07.254455          Saving settings file "H:\BOINC\BOINC_DATA\slots\4\boinc_55fed40b3b756a0e\boinc_55fed40b3b756a0e.vbox" with version "1.16-windows"
00:00:07.333351          Saving settings file "H:\BOINC\BOINC_DATA\slots\5\boinc_58d939c9dfed65a5\boinc_58d939c9dfed65a5.vbox" with version "1.16-windows"
00:00:07.397769          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.397904          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.408519          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:07.487436          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.487567          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.503659          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:07.561541          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.561697          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.571047          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:07.636411          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.636548          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.644697          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:07.691924          Launched VM: 77577648 pid: 20204 (0x4eec) frontend: headless name: boinc_63fc7e55e268ce16
00:00:07.767284          Launched VM: 76861760 pid: 3108 (0xc24) frontend: headless name: boinc_59d713cb2ff901cc
00:00:07.840568          Launched VM: 77257104 pid: 22160 (0x5690) frontend: headless name: boinc_55fed40b3b756a0e
00:00:07.986543          Launched VM: 77539824 pid: 13632 (0x3540) frontend: headless name: boinc_58d939c9dfed65a5
00:00:11.662659          Saving settings file "H:\BOINC\BOINC_DATA\slots\7\boinc_63fc7e55e268ce16\boinc_63fc7e55e268ce16.vbox" with version "1.16-windows"
00:00:11.786014          Saving settings file "H:\BOINC\BOINC_DATA\slots\4\boinc_55fed40b3b756a0e\boinc_55fed40b3b756a0e.vbox" with version "1.16-windows"
00:00:11.795133          Saving settings file "H:\BOINC\BOINC_DATA\slots\6\boinc_59d713cb2ff901cc\boinc_59d713cb2ff901cc.vbox" with version "1.16-windows"
00:00:11.959118          Saving settings file "H:\BOINC\BOINC_DATA\slots\5\boinc_58d939c9dfed65a5\boinc_58d939c9dfed65a5.vbox" with version "1.16-windows"
00:00:12.008008          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:12.108574          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:12.126787          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:12.229962          Saving settings file "H:\BOINC\BOINC_DATA\slots\7\boinc_63fc7e55e268ce16\boinc_63fc7e55e268ce16.vbox" with version "1.16-windows"
00:00:12.397425          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:12.397841          Saving settings file "H:\BOINC\BOINC_DATA\slots\6\boinc_59d713cb2ff901cc\boinc_59d713cb2ff901cc.vbox" with version "1.16-windows"
00:00:12.398135          Saving settings file "H:\BOINC\BOINC_DATA\slots\4\boinc_55fed40b3b756a0e\boinc_55fed40b3b756a0e.vbox" with version "1.16-windows"
00:00:12.711805          Saving settings file "H:\BOINC\BOINC_DATA\slots\5\boinc_58d939c9dfed65a5\boinc_58d939c9dfed65a5.vbox" with version "1.16-windows"
00:00:12.763449          Saving settings file "C:\Users\Ken\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:12.816080          Saving settings file "C:\Users\Ken\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:12.891346          Saving settings file "C:\Users\Ken\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:12.987800          Saving settings file "C:\Users\Ken\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:18.288433 main     VirtualBox: object deletion starts
00:00:18.288996 main     HostDnsMonitor: shutting down ...
00:00:18.289084 main     HostDnsMonitor: shut down
00:00:18.291113 Watcher  ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0
00:00:18.291346 main     VirtualBox: object deleted

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

 Port:    2
Maximum PIIX3 SATA Controllers:  1
Maximum ICH9 SATA Controllers:   8
Maximum SATA Port count:         30
Maximum Devices per SATA Port:   1
Maximum PIIX3 SCSI Controllers:  1
Maximum ICH9 SCSI Controllers:   8
Maximum SCSI Port count:         16
Maximum Devices per SCSI Port:   1
Maximum SAS PIIX3 Controllers:   1
Maximum SAS ICH9 Controllers:    8
Maximum SAS Port count:          255
Maximum Devices per SAS Port:    1
Maximum NVMe PIIX3 Controllers:  1
Maximum NVMe ICH9 Controllers:   8
Maximum NVMe Port count:         255
Maximum Devices per NVMe Port:   1
Maximum virtio-scsi PIIX3 Controllers:  1
Maximum virtio-scsi ICH9 Controllers:   8
Maximum virtio-scsi Port count:         256
Maximum Devices per virtio-scsi Port:   1
Maximum PIIX3 Floppy Controllers:1
Maximum ICH9 Floppy Controllers: 1
Maximum Floppy Port count:       1
Maximum Devices per Floppy Port: 2
Default machine folder:          C:\Users\Ken\VirtualBox VMs
Raw-mode Supported:              no
Exclusive HW virtualization use: off
Default hard disk format:        VDI
VRDE auth library:               VBoxAuth
Webservice auth. library:        VBoxAuth
Remote desktop ExtPack:          
Log history count:               3
Default frontend:                
Default audio driver:            DirectSound
Autostart database path:         
Default Guest Additions ISO:     C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso
Logging Level:                   all
Proxy Mode:                      System
Proxy URL:                       

2020-10-09 02:49:17 (18440): 
Command: VBoxManage -q list hostinfo 
Exit Code: 0
Output:
Host Information:

Host time: 2020-10-09T06:49:17.083000000Z
Processor online count: 4
Processor count: 4
Processor online core count: 4
Processor core count: 4
Processor supports HW virtualization: no
Processor supports PAE: yes
Processor supports long mode: yes
Processor supports nested paging: no
Processor supports unrestricted guest: no
Processor supports nested HW virtualization: no
Processor#0 speed: unknown
Processor#0 description: Intel(R) Core(TM) i5-4670K CPU @ 3.40GHz
Processor#1 speed: unknown
Processor#1 description: Intel(R) Core(TM) i5-4670K CPU @ 3.40GHz
Processor#2 speed: unknown
Processor#2 description: Intel(R) Core(TM) i5-4670K CPU @ 3.40GHz
Processor#3 speed: unknown
Processor#3 description: Intel(R) Core(TM) i5-4670K CPU @ 3.40GHz
Memory size: 32706 MByte
Memory available: 19439 MByte
Operating system: Windows 10
Operating system version: 10.0.19041

2020-10-09 02:49:17 (18440): 
Command: VBoxManage -q showvminfo "boinc_63fc7e55e268ce16" --machinereadable 
Exit Code: -2135228415
Output:
VBoxManage.exe: error: Could not find a registered machine named 'boinc_63fc7e55e268ce16'
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown
VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2715 of file VBoxManageInfo.cpp

2020-10-09 02:49:17 (18440): 
Command: VBoxManage -q showhdinfo "H:\BOINC\BOINC_DATA\slots\7/vm_image.vdi" 
Exit Code: -2135228412
Output:
VBoxManage.exe: error: Could not find file for the medium 'H:\BOINC\BOINC_DATA\slots\7\vm_image.vdi' (VERR_FILE_NOT_FOUND)
VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp

2020-10-09 02:49:18 (18440): 
Command: VBoxManage -q createvm --name "boinc_63fc7e55e268ce16" --basefolder "H:\BOINC\BOINC_DATA\slots\7" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_63fc7e55e268ce16' is created and registered.
UUID: 344af7bc-f7de-4aa0-ab25-162e3a058c2b
Settings file: 'H:\BOINC\BOINC_DATA\slots\7\boinc_63fc7e55e268ce16\boinc_63fc7e55e268ce16.vbox'

2020-10-09 02:49:18 (18440): 
Command: VBoxManage -q modifyvm "boinc_63fc7e55e268ce16" --description "07971660_07_2" 
Exit Code: 0
Output:

2020-10-09 02:49:18 (18440): 
Command: VBoxManage -q modifyvm "boinc_63fc7e55e268ce16" --memory 3072 
Exit Code: 0
Output:

2020-10-09 02:49:18 (18440): 
Command: VBoxManage -q modifyvm "boinc_63fc7e55e268ce16" --cpus 1 
Exit Code: 0
Output:

2020-10-09 02:49:19 (18440): 
Command: VBoxManage -q modifyvm "boinc_63fc7e55e268ce16" --acpi on --ioapic on 
Exit Code: 0
Output:

2020-10-09 02:49:19 (18440): 
Command: VBoxManage -q modifyvm "boinc_63fc7e55e268ce16" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2020-10-09 02:49:19 (18440): 
Command: VBoxManage -q modifyvm "boinc_63fc7e55e268ce16" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2020-10-09 02:49:20 (18440): 
Command: VBoxManage -q modifyvm "boinc_63fc7e55e268ce16" --cableconnected1 on 
Exit Code: 0
Output:

2020-10-09 02:49:20 (18440): 
Command: VBoxManage -q modifyvm "boinc_63fc7e55e268ce16" --usb off 
Exit Code: 0
Output:

2020-10-09 02:49:20 (18440): 
Command: VBoxManage -q modifyvm "boinc_63fc7e55e268ce16" --uart1 off --uart2 off 
Exit Code: 0
Output:

2020-10-09 02:49:21 (18440): 
Command: VBoxManage -q modifyvm "boinc_63fc7e55e268ce16" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2020-10-09 02:49:21 (18440): 
Command: VBoxManage -q modifyvm "boinc_63fc7e55e268ce16" --audio none 
Exit Code: 0
Output:

2020-10-09 02:49:21 (18440): 
Command: VBoxManage -q modifyvm "boinc_63fc7e55e268ce16" --clipboard disabled 
Exit Code: 0
Output:

2020-10-09 02:49:21 (18440): 
Command: VBoxManage -q modifyvm "boinc_63fc7e55e268ce16" --draganddrop disabled 
Exit Code: 0
Output:

2020-10-09 02:49:22 (18440): 
Command: VBoxManage -q storagectl "boinc_63fc7e55e268ce16" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2020-10-09 02:49:22 (18440): 
Command: VBoxManage -q storageattach "boinc_63fc7e55e268ce16" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "H:\BOINC\BOINC_DATA\slots\7/vm_isocontext.iso" 
Exit Code: 0
Output:

2020-10-09 02:49:22 (18440): 
Command: VBoxManage -q storageattach "boinc_63fc7e55e268ce16" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2020-10-09 02:49:23 (18440): 
Command: VBoxManage -q bandwidthctl "boinc_63fc7e55e268ce16" add "boinc_63fc7e55e268ce16_net" --type network --limit 1024G 
Exit Code: 0
Output:

2020-10-09 02:49:23 (18440): 
Command: VBoxManage -q sharedfolder add "boinc_63fc7e55e268ce16" --name "shared" --hostpath "H:\BOINC\BOINC_DATA\slots\7/shared"
Exit Code: 0
Output:

2020-10-09 02:49:27 (18440): 
Command: VBoxManage -q startvm "boinc_63fc7e55e268ce16" --type headless
Exit Code: -2147467259
Output:
Waiting for VM "boinc_63fc7e55e268ce16" to power on...
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole

2020-10-09 02:49:28 (18440): 
Command: VBoxManage -q snapshot "boinc_63fc7e55e268ce16" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2020-10-09 02:49:28 (18440): 
Command: VBoxManage -q bandwidthctl "boinc_63fc7e55e268ce16" remove "boinc_63fc7e55e268ce16_net" 
Exit Code: 0
Output:

2020-10-09 02:49:29 (18440): 
Command: VBoxManage -q unregistervm "boinc_63fc7e55e268ce16" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

2020-10-09 02:49:29 (18440): 
Command: VBoxManage -q closemedium dvd "H:\BOINC\BOINC_DATA\slots\7/vm_isocontext.iso" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

02:49:36 (18440): called boinc_finish(-2147467259)

</stderr_txt>
]]>


©2025 COPYRIGHT 2017-2018 NCN