Task 9966414

Name 07978183_19_3
Workunit 7762854
Created 13 Oct 2020, 7:04:40 UTC
Sent 13 Oct 2020, 8:05:28 UTC
Report deadline 18 Oct 2020, 8:05:28 UTC
Received 13 Oct 2020, 9:15:19 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status -2147467259 (0x80004005) Unknown error code
Computer ID 8612
Run time 17 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 4.01 GFLOPS
Application version boinc2docker v1.14 (vbox64_mt)
windows_x86_64
Peak working set size 11.47 MB
Peak swap size 6.22 MB
Peak disk usage 600.55 MB

Stderr output

<core_client_version>7.16.11</core_client_version>
<![CDATA[
<message>
Unspecified error
 (0x80004005) - exit code 2147500037 (0x80004005)</message>
<stderr_txt>
2020-10-13 03:07:06 (7452): Detected: vboxwrapper 26202
2020-10-13 03:07:06 (7452): Detected: BOINC client v7.16.11
2020-10-13 03:07:06 (7452): Detected: VirtualBox VboxManage Interface (Version: 6.1.12)
2020-10-13 03:07:07 (7452): Create VM. (boinc_e9c03671aae96a19, slot#10)
2020-10-13 03:07:07 (7452): Updating drive controller type and model for desired configuration.
2020-10-13 03:07:08 (7452): Setting Memory Size for VM. (3072MB)
2020-10-13 03:07:08 (7452): Setting CPU Count for VM. (1)
2020-10-13 03:07:08 (7452): Setting Chipset Options for VM.
2020-10-13 03:07:08 (7452): Setting Boot Options for VM.
2020-10-13 03:07:09 (7452): Setting Network Configuration for NAT.
2020-10-13 03:07:09 (7452): Enabling VM Network Access.
2020-10-13 03:07:09 (7452): Disabling USB Support for VM.
2020-10-13 03:07:10 (7452): Disabling COM Port Support for VM.
2020-10-13 03:07:10 (7452): Disabling LPT Port Support for VM.
2020-10-13 03:07:10 (7452): Disabling Audio Support for VM.
2020-10-13 03:07:10 (7452): Disabling Clipboard Support for VM.
2020-10-13 03:07:11 (7452): Disabling Drag and Drop Support for VM.
2020-10-13 03:07:11 (7452): Adding storage controller(s) to VM.
2020-10-13 03:07:11 (7452): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso)
2020-10-13 03:07:11 (7452): Adding VirtualBox Guest Additions to VM.
2020-10-13 03:07:12 (7452): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2020-10-13 03:07:12 (7452): Enabling shared directory for VM.
2020-10-13 03:07:13 (7452): Starting VM using VBoxManage interface. (boinc_e9c03671aae96a19, slot#10)
2020-10-13 03:07:15 (7452): Error in start VM for VM: -2147467259
Command:
VBoxManage -q startvm "boinc_e9c03671aae96a19" --type headless
Output:
Waiting for VM "boinc_e9c03671aae96a19" to power on...
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: AMD-V is disabled in the BIOS (or by the host OS) (VERR_SVM_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole

2020-10-13 03:07:15 (7452): VM failed to start.
2020-10-13 03:07:15 (7452): Could not start 
2020-10-13 03:07:15 (7452): ERROR: VM failed to start
2020-10-13 03:07:15 (7452): Powering off VM.
2020-10-13 03:07:15 (7452): Deregistering VM. (boinc_e9c03671aae96a19, slot#10)
2020-10-13 03:07:15 (7452): Removing network bandwidth throttle group from VM.
2020-10-13 03:07:15 (7452): Removing VM from VirtualBox.
2020-10-13 03:07:15 (7452): Removing virtual ISO 9660 disk from VirtualBox.

    Hypervisor System Log:

00:00:08.329570          Saving settings file "C:\Users\tfenu\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:08.341685          Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_e3a1401ff64c8af3\boinc_e3a1401ff64c8af3.vbox" with version "1.16-windows"
00:00:08.480577          Saving settings file "C:\ProgramData\BOINC\slots\10\boinc_e9c03671aae96a19\boinc_e9c03671aae96a19.vbox" with version "1.16-windows"
00:00:08.593630          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.594031          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.594627          Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_e3a1401ff64c8af3\boinc_e3a1401ff64c8af3.vbox" with version "1.16-windows"
00:00:08.744586          Saving settings file "C:\ProgramData\BOINC\slots\10\boinc_e9c03671aae96a19\boinc_e9c03671aae96a19.vbox" with version "1.16-windows"
00:00:08.856428          Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_e3a1401ff64c8af3\boinc_e3a1401ff64c8af3.vbox" with version "1.16-windows"
00:00:09.012145          Saving settings file "C:\ProgramData\BOINC\slots\10\boinc_e9c03671aae96a19\boinc_e9c03671aae96a19.vbox" with version "1.16-windows"
00:00:09.128332          Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_e3a1401ff64c8af3\boinc_e3a1401ff64c8af3.vbox" with version "1.16-windows"
00:00:09.278912          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:09.280566          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:09.280734          Saving settings file "C:\Users\tfenu\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:09.290819          Saving settings file "C:\Users\tfenu\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:09.295191          Saving settings file "C:\ProgramData\BOINC\slots\10\boinc_e9c03671aae96a19\boinc_e9c03671aae96a19.vbox" with version "1.16-windows"
00:00:09.336590          Saving settings file "C:\ProgramData\BOINC\slots\11\boinc_d4840d6391be83dd\boinc_d4840d6391be83dd.vbox" with version "1.16-windows"
00:00:09.402383          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:09.402537          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:09.409176          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:09.434225          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:09.502202          Saving settings file "C:\ProgramData\BOINC\slots\11\boinc_d4840d6391be83dd\boinc_d4840d6391be83dd.vbox" with version "1.16-windows"
00:00:09.548660          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:09.549038          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:09.549526          Saving settings file "C:\ProgramData\BOINC\slots\10\boinc_e9c03671aae96a19\boinc_e9c03671aae96a19.vbox" with version "1.16-windows"
00:00:09.581654          Saving settings file "C:\ProgramData\BOINC\slots\12\boinc_dddccf3f5e1f85a6\boinc_dddccf3f5e1f85a6.vbox" with version "1.16-windows"
00:00:09.652053          Launched VM: 62136384 pid: 14688 (0x3960) frontend: headless name: boinc_e3a1401ff64c8af3
00:00:09.670718          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:09.769530          Saving settings file "C:\Users\tfenu\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:09.825818          Saving settings file "C:\ProgramData\BOINC\slots\10\boinc_e9c03671aae96a19\boinc_e9c03671aae96a19.vbox" with version "1.16-windows"
00:00:10.005741          Saving settings file "C:\Users\tfenu\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:10.102910          Saving settings file "C:\ProgramData\BOINC\slots\10\boinc_e9c03671aae96a19\boinc_e9c03671aae96a19.vbox" with version "1.16-windows"
00:00:10.376249          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:10.376460          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:10.381738          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:10.656717          Launched VM: 62506912 pid: 6564 (0x19a4) frontend: headless name: boinc_e9c03671aae96a19
00:00:11.716466          Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_e3a1401ff64c8af3\boinc_e3a1401ff64c8af3.vbox" with version "1.16-windows"
00:00:11.791468          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:12.110547          Saving settings file "C:\Users\tfenu\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:12.620004          Saving settings file "C:\ProgramData\BOINC\slots\10\boinc_e9c03671aae96a19\boinc_e9c03671aae96a19.vbox" with version "1.16-windows"
00:00:12.699189          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:13.031478          Saving settings file "C:\Users\tfenu\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:18.329019 main     VirtualBox: object deletion starts
00:00:18.329515 main     HostDnsMonitor: shutting down ...
00:00:18.329539 main     HostDnsMonitor: shut down
00:00:18.331156 Watcher  ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0
00:00:18.331326 main     VirtualBox: object deleted

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:


Maximum PIIX3 Floppy Controllers:1
Maximum ICH9 Floppy Controllers: 1
Maximum Floppy Port count:       1
Maximum Devices per Floppy Port: 2
Default machine folder:          C:\Users\tfenu\VirtualBox VMs
Raw-mode Supported:              no
Exclusive HW virtualization use: off
Default hard disk format:        VDI
VRDE auth library:               VBoxAuth
Webservice auth. library:        VBoxAuth
Remote desktop ExtPack:          
Log history count:               3
Default frontend:                
Default audio driver:            DirectSound
Autostart database path:         
Default Guest Additions ISO:     C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso
Logging Level:                   all
Proxy Mode:                      System
Proxy URL:                       

2020-10-13 03:07:06 (7452): 
Command: VBoxManage -q list hostinfo 
Exit Code: 0
Output:
Host Information:

Host time: 2020-10-13T08:07:06.660000000Z
Processor online count: 12
Processor count: 12
Processor online core count: 6
Processor core count: 6
Processor supports HW virtualization: no
Processor supports PAE: yes
Processor supports long mode: yes
Processor supports nested paging: no
Processor supports unrestricted guest: no
Processor supports nested HW virtualization: no
Processor#0 speed: unknown
Processor#0 description: AMD Ryzen 5 1600 Six-Core Processor
Processor#1 speed: unknown
Processor#1 description: AMD Ryzen 5 1600 Six-Core Processor
Processor#2 speed: unknown
Processor#2 description: AMD Ryzen 5 1600 Six-Core Processor
Processor#3 speed: unknown
Processor#3 description: AMD Ryzen 5 1600 Six-Core Processor
Processor#4 speed: unknown
Processor#4 description: AMD Ryzen 5 1600 Six-Core Processor
Processor#5 speed: unknown
Processor#5 description: AMD Ryzen 5 1600 Six-Core Processor
Processor#6 speed: unknown
Processor#6 description: AMD Ryzen 5 1600 Six-Core Processor
Processor#7 speed: unknown
Processor#7 description: AMD Ryzen 5 1600 Six-Core Processor
Processor#8 speed: unknown
Processor#8 description: AMD Ryzen 5 1600 Six-Core Processor
Processor#9 speed: unknown
Processor#9 description: AMD Ryzen 5 1600 Six-Core Processor
Processor#10 speed: unknown
Processor#10 description: AMD Ryzen 5 1600 Six-Core Processor
Processor#11 speed: unknown
Processor#11 description: AMD Ryzen 5 1600 Six-Core Processor
Memory size: 16331 MByte
Memory available: 8884 MByte
Operating system: Windows 10
Operating system version: 10.0.19041

2020-10-13 03:07:07 (7452): 
Command: VBoxManage -q showvminfo "boinc_e9c03671aae96a19" --machinereadable 
Exit Code: -2135228415
Output:
VBoxManage.exe: error: Could not find a registered machine named 'boinc_e9c03671aae96a19'
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown
VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2715 of file VBoxManageInfo.cpp

2020-10-13 03:07:07 (7452): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\10/vm_image.vdi" 
Exit Code: -2135228412
Output:
VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\10\vm_image.vdi' (VERR_FILE_NOT_FOUND)
VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp

2020-10-13 03:07:07 (7452): 
Command: VBoxManage -q createvm --name "boinc_e9c03671aae96a19" --basefolder "C:\ProgramData\BOINC\slots\10" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_e9c03671aae96a19' is created and registered.
UUID: 1e767bb0-9eec-43f9-8083-13a7fc5f116a
Settings file: 'C:\ProgramData\BOINC\slots\10\boinc_e9c03671aae96a19\boinc_e9c03671aae96a19.vbox'

2020-10-13 03:07:08 (7452): 
Command: VBoxManage -q modifyvm "boinc_e9c03671aae96a19" --description "07978183_19_3" 
Exit Code: 0
Output:

2020-10-13 03:07:08 (7452): 
Command: VBoxManage -q modifyvm "boinc_e9c03671aae96a19" --memory 3072 
Exit Code: 0
Output:

2020-10-13 03:07:08 (7452): 
Command: VBoxManage -q modifyvm "boinc_e9c03671aae96a19" --cpus 1 
Exit Code: 0
Output:

2020-10-13 03:07:08 (7452): 
Command: VBoxManage -q modifyvm "boinc_e9c03671aae96a19" --acpi on --ioapic on 
Exit Code: 0
Output:

2020-10-13 03:07:09 (7452): 
Command: VBoxManage -q modifyvm "boinc_e9c03671aae96a19" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2020-10-13 03:07:09 (7452): 
Command: VBoxManage -q modifyvm "boinc_e9c03671aae96a19" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2020-10-13 03:07:09 (7452): 
Command: VBoxManage -q modifyvm "boinc_e9c03671aae96a19" --cableconnected1 on 
Exit Code: 0
Output:

2020-10-13 03:07:10 (7452): 
Command: VBoxManage -q modifyvm "boinc_e9c03671aae96a19" --usb off 
Exit Code: 0
Output:

2020-10-13 03:07:10 (7452): 
Command: VBoxManage -q modifyvm "boinc_e9c03671aae96a19" --uart1 off --uart2 off 
Exit Code: 0
Output:

2020-10-13 03:07:10 (7452): 
Command: VBoxManage -q modifyvm "boinc_e9c03671aae96a19" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2020-10-13 03:07:10 (7452): 
Command: VBoxManage -q modifyvm "boinc_e9c03671aae96a19" --audio none 
Exit Code: 0
Output:

2020-10-13 03:07:11 (7452): 
Command: VBoxManage -q modifyvm "boinc_e9c03671aae96a19" --clipboard disabled 
Exit Code: 0
Output:

2020-10-13 03:07:11 (7452): 
Command: VBoxManage -q modifyvm "boinc_e9c03671aae96a19" --draganddrop disabled 
Exit Code: 0
Output:

2020-10-13 03:07:11 (7452): 
Command: VBoxManage -q storagectl "boinc_e9c03671aae96a19" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2020-10-13 03:07:11 (7452): 
Command: VBoxManage -q storageattach "boinc_e9c03671aae96a19" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\ProgramData\BOINC\slots\10/vm_isocontext.iso" 
Exit Code: 0
Output:

2020-10-13 03:07:12 (7452): 
Command: VBoxManage -q storageattach "boinc_e9c03671aae96a19" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2020-10-13 03:07:12 (7452): 
Command: VBoxManage -q bandwidthctl "boinc_e9c03671aae96a19" add "boinc_e9c03671aae96a19_net" --type network --limit 1024G 
Exit Code: 0
Output:

2020-10-13 03:07:12 (7452): 
Command: VBoxManage -q sharedfolder add "boinc_e9c03671aae96a19" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\10/shared"
Exit Code: 0
Output:

2020-10-13 03:07:15 (7452): 
Command: VBoxManage -q startvm "boinc_e9c03671aae96a19" --type headless
Exit Code: -2147467259
Output:
Waiting for VM "boinc_e9c03671aae96a19" to power on...
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: AMD-V is disabled in the BIOS (or by the host OS) (VERR_SVM_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole

2020-10-13 03:07:15 (7452): 
Command: VBoxManage -q snapshot "boinc_e9c03671aae96a19" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2020-10-13 03:07:15 (7452): 
Command: VBoxManage -q bandwidthctl "boinc_e9c03671aae96a19" remove "boinc_e9c03671aae96a19_net" 
Exit Code: 0
Output:
VBoxManage.exe: error: Bandwidth groups cannot be deleted while the VM is running

2020-10-13 03:07:15 (7452): 
Command: VBoxManage -q unregistervm "boinc_e9c03671aae96a19" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

2020-10-13 03:07:15 (7452): 
Command: VBoxManage -q closemedium dvd "C:\ProgramData\BOINC\slots\10/vm_isocontext.iso" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

03:07:21 (7452): called boinc_finish(-2147467259)

</stderr_txt>
]]>


©2024 COPYRIGHT 2017-2018 NCN